F00	Data protection
F01	Frequency command 1
F02	Operation method
F03	Maximum frequency
F04	Base frequency
F05	Rated voltage (at base freqency)
F07	Acceleration time 1
F08	Deceleration time 1
F09	Torque boost
F10	Electronic thermal (Select the motor property)
F11	Electronic thermal (Overload detection level)
F12	Electronic thermal (Thermal time constant)
F14	Restart mode after momentary power failure (Select)
F15	Frequency limiter (Peak)
F16	Frequency limiter (Bottom)
F18	Bais (for F01)
F20	DC brake (Starting frequency)
F21	DC brake (Braking level)
F22	DC brake (Braking time)
F23	Starting frequency
F25	Stop frequency
F26	Motor sound (Carrier frequency)
F27	Motor sound (Sound tone)
F29	FMA terminal (Select)
F30	FMA terminal (Output gain)
F31	FMA terminal (Monitor object)
F34	FMI terminal (Output gain)
F35	FMI terminal (Monitor object)
F37	Load select/Auto torque boost/Energy-saving ope.
F43	Current limiter (Operation condition)
F44	Current limiter (Level)
[F-SigDataEnd]

[E-SigData]
E01	X1 terminal Command Assignment
E02	X2 terminal Command Assignment
E03	X3 terminal Command Assignment
E04	X4 terminal Command Assignment
E05	X5 terminal Command Assignment
E20	Y1 terminal Command Assignment
E21	Y2 terminal Command Assignment
E22	Y3 terminal Command Assignment
E24	Y5A/Y5C terminal Command Assignment
E27	30ABC Ry output Command Assignment
E31	Frequency detection [FDT] (Level)
E32	Frequency Detection (FDT) (Hysteresis width)
E34	OL early warning/Current detection (Level)
E35	OL early warning/Current detection (Timer)
E40	PID display coefficient A
E41	PID display coefficient B
E43	LED Monitor Item Selection
E45	LCD Monitor Item Selection
E46	LCD Monitor Language Selection
E47	LCD Monitor Contrast Control
E48	LED Monitor (Speed monitor item)
E50	Coefficient for Speed Indication
E51	Power rate coefficient
E52	Keypad (Menu display mode)
E61	12 terminal (Extension function select)
E62	C1 terminal (Extension function select)
E63	V2 terminal (Extension function select)
E64	Memory of Digital frequency reference
E65	Reference Loss Detection
E80	Low level torque detection (Level)
E81	Low level torque detection (Timer)
E98	FWD terminal Command Assignment
E99	REV terminal Command Assignment
[E-SigDataEnd]

[C-SigData]
C01	Jump freqency 1
C02	Jump freqency 2
C03	Jump freqency 3
C04	Jump freqency band
C05	Multi-step frequency setting 1
C06	Multi-step frequency setting 2
C07	Multi-step frequency setting 3
C08	Multi-step frequency setting 4
C09	Multi-step frequency setting 5
C10	Multi-step frequency setting 6
C11	Multi-step frequency setting 7
C30	Frequency command 2
C32	[12] Analog input adj. (Gain)
C33	[12] Analog input adj. (Filter)
C34	[12] Analog input adj. (Gain reference point)
C37	[C1] Analog input adj. (Gain)
C38	[C1] Analog input adj. (Filter)
C39	[C1] Analog input adj. (Gain reference point)
C42	[V2] Analog input adj. (Gain)
C43	[V2] Analog input adj. (Filter)
C44	[V2] Analog input adj. (Gain reference point)
C50	Bias [Freq. command 1] (Bias reference point)
C51	Bias [PID command 1] (Bias value)
C52	Bias [PID command 1] (Bias reference point)
C53	Inverse mode operation selection (Freq. setting 1)
[C-SigDataEnd]

[P-SigData]
P01	Motor (Number of motor poles)
P02	Motor (Rated capacity)
P03	Motor (Rated current)
P06	Motor (No load current)
P07	Motor (%R1)
P08	Motor (%X)
P99	Motor Selection
[P-SigDataEnd]

[H-SigData]
H03	Data initializing (Data reset)
H04	Retry (No. of retries)
H05	Retry (Latency time)
H06	Cooling Fan ON/OFF
H07	Gradual Acceleration/Deceleration
H09	Starting Characteristics (Synchronization mode)
H11	Deceleration mode
H12	Instantaneous overcurrent limiting (Specify ope.)
H13	Instantaneous Power Failure Restart(Waiting time)
H14	Instantaneous Power Failure Restart(Freq.fall rate)
H15	Instantaneous Power Failure Restart(Level)
H16	Instantaneous Power Failure Restart(Allowable time)
H17	Starting Characteristics (Synchronous frequency)
H26	PTC Thermistor input (Specify operation)
H27	PTC Thermistor input (Level)
H30	Communication Link Operation (Function select)
H42	Capacitor of DC Link Bus Capcitor
H43	Accumulated Run time of Cooling fan
H47	Initial Capacitor of DC Link Bus Capcitor
H48	Accumulated Run time of Capacitors on the PCB
H49	Starting Characteristics (Waiting time)
H50	Arbitrary point on Non-linear V/f line (Frequency)
H51	Arbitrary point on Non-linear V/f line (Voltage)
H56	Deceleration time for Forced stop
H63	Bottom limiter details (Specify operation)
H64	Bottom limiter (Min.freq.when limiter is activated)
H69	Automatic deceleration (Specify operation)
H70	Overload prevention control (Frequency drop rate)
H71	Deceleration Characteristics
H80	Gain for Suppression of Output Current Fluctuation
H91	PID control feedback disconnection detection (Terminal[C1])
H92	Continue to Run (P component : Gain)
H93	Continue to Run (I component : Time)
H94	Accumulated Run Time of Motor
H95	DC brake (Breaking response mode)
H96	STOP key priority / Start check function
H97	Clear alarm data
H98	Protection/maintenance function (Specify operation)
[H-SigDataEnd]

[S-SigData]
S01	Frequency command (p.u.)
S05	Frequency command
S06	Operation command
S07	Universal Do
S08	Acceleration time F07
S09	Deceleration time F09
S12	Universal Ao
S13	PID command
S14	Alarm reset command
[S-SigDataEnd]

[M-SigData]
M01	Frequency command (p.u.) (Final command)
M05	Frequency command (Final command)
M06	Output frequency 1(p.u.)
M07	Torque real value
M09	Output frequency 1
M10	Input power
M11	Output current effective value
M12	Output voltage effective value
M13	Operation command (Final command)
M14	Operation status
M15	General-purpose output terminal information
M16	Latest contents of alarm
M17	Last contents of alarm
M18	Second last contents of alarm
M19	Third last contents of alarm
M20	Cumulative operation time
M21	DC link circuit voltage
M23	Model code
M24	Capacity code
M25	ROM version
M26	Transmission error transaction code
M27	Frequency command on alarm (p.u.)(Final command)
M31	Frequency command on alarm (Final command)
M32	Output frequency 1 on alarm (p.u.)
M33	Torque real value on alarm
M35	Output frequency 1 on alarm
M36	Input power on alarm
M37	Output current effective value on alarm
M38	Output voltage effective value on alarm
M39	Operation command on alarm
M40	Operation status on alarm
M41	Output terminal information on alarm
M42	Cumulative operation time on alarm
M43	DC link circuit voltage on alarm
M44	Temperature inside inverter on alarm
M45	Heat sink temperature on alarm
M46	Life of main circuit capacitor
M47	Life of PC board electrolytic capacitor
M48	Life of cooling fan
M49	Input terminal voltage[12] (p.u.)
M50	Input terminal current[C1] (p.u.)
M54	Input terminal voltage[V2] (p.u.)
M61	Temperature inside inverter
M62	Heat sink temperature
M63	Load factor
M64	Motor output
M65	Motor output on alarm
M68	PID final command
M69	Inverter rated current
M70	Operation status 2
M71	Input terminal information (Operation command)
M72	PID feedback value
M73	PID output
[M-SigDataEnd]

[J-SigData]
J01	PID control (Specify operation)
J02	PID control (Remote process command)
J03	PID control P (gain)
J04	PID control I (Integration time)
J05	PID control D (Differentiation time)
J06	PID control (Feedback filter)
J10	PID control (Anti-reset wind-up)
J11	PID control (Select alarm output)
J12	PID control (Peak limit alarm (AH))
J13	PID control (Bottom limit alarm (AL))
J15	PID control (Stop frequency for slow flowrate)
J16	PID control (Elapsed stop time for slow flowrate)
J17	PID control (Starting frequency)
J18	PID control (Upper limit of PID process output)
J19	PID control (Lower limit of PID process output)
J21	Dew Condensation Protection (Duty)
J22	Commercial Line Switching Sequence
J25	Pump Control (Mode selection)
J26	Motor 1 Mode
J27	Motor 2 Mode
J28	Motor 3 Mode
J29	Motor 4 Mode
J30	Motor Switching Order
J31	Motor Stop Mode
J32	Periodic Switching Time for Motor Drive
J33	Periodic Switching Signaling Period
J34	Mount of Commercial Power-driven Motor(Frequency)
J35	Mount of Commercial Power-driven Motor(Duration)
J36	Unmount of Commercial Power-driven Motor(Frequency)
J37	Unmount of Commercial Power-driven Motor(Duration)
J38	Contactor Delay Time
J39	Switching Time for Motor Mount(Deceleration time)
J40	Switching Time for Motor Unmount(Acceleration time)
J41	Motor Mount/Unmount Switching Level
J42	Switching Motor Mount/Unmount(Dead band)
J43	PID Control Startup Frequency
J45	Signal Assignment to: [Y1A/B/C]
J46	Signal Assignment to: [Y2A/B/C]
J47	Signal Assignment to: [Y3A/B/C]
J48	Cumulative Run Time of Motor(Motor 0)
J49	Cumulative Run Time of Motor(Motor 1)
J50	Cumulative Run Time of Motor(Motor 2)
J51	Cumulative Run Time of Motor(Motor 3)
J52	Cumulative Run Time of Motor(Motor 4)
J53	Num. of Relay ON Times [Y1A/B/C] to [Y3A/B/C]
J54	Num. of Y terminal ON Times [Y1] to [Y3]
J55	Num. of Relay ON Times [Y5A] ; [30A/B/C]
[J-SigDataEnd]

[y-SigData]
y01	RS485 (Station address)
y02	RS485 (Mode select on no response error)
y03	RS485 (Timer)
y04	RS485 (Baud rate)
y05	RS485 (Data length)
y06	RS485 (Parity check)
y07	RS485 (Stop bits)
y08	RS485 (No response error detection time)
y09	RS485 (Response interval)
y10	RS485 (Protocol selection)
y11	RS485 [Option] (Station address)
y12	RS485 [Option] (Mode select on no response error)
y13	RS485 [Option] (Timer)
y14	RS485 [Option] (Baud rate)
y15	RS485 [Option] (Data length)
y16	RS485 [Option] (Parity check)
y17	RS485 [Option] (Stop bits)
y18	RS485 [Option] (No response error detection time)
y19	RS485 [Option] (Response interval)
y20	RS485 [Option] (Protocol selection)
y98	Bus Link function for supporting data input
y99	Loader Link function for supporting data input
[y-SigDataEnd]

[o-SigData]
o27	Option
o28	Option
o30	Option
o31	Option
o32	Option
o33	Option
o34	Option
o35	Option
o36	Option
o37	Option
o38	Option
o39	Option
o40	Option
o41	Option
o42	Option
o43	Option
o44	Option
o45	Option
o46	Option
o47	Option
o48	Option
o49	Option
o50	Option
o51	Option
o52	Option
o53	Option
o54	Option
o55	Option
o56	Option
o57	Option
o58	Option
o59	Option
[o-SigDataEnd]

[W-SigData]
W01	Operation status
W02	Frequency command
W03	Output command (before slip compensation)
W05	Output current
W06	Output voltage
W07	Truqe
W08	Rotation speed
W09	Load rotation speed
W11	PID process command
W12	PID feedback value
W16	Rotation speed set value
W17	Load speed set value
W21	Input power
W22	Motor output
W23	Load rate
W28	Operation command source
W29	Frequency command source
W30	Speed at pecentage
W31	Speed set value at pecentage
W32	PID output
W33	Analog input monitor
W40	Control circuit terminal (input)
W41	Control circuit terminal (output)
W42	Communications control signal (input)
W43	Communications control signal (output)
W44	Terminal [12]input voltage
W45	Terminal [C1]input current
W46	FMA output voltage
W47	FMP output voltage
W48	FMP output frequency
W49	V2 terminal input voltage
W50	FMA output current
W65	FMI output current
W67	Cumulative Run Time of Electrolytic Capacitors on PC Board
W68	Cumulative Run Time of Cooling Fan
W70	Cumulative operation time
W71	DC link circuit voltage
W72	Heat sink maximum temperature
W73	Heat sink maximum temperature
W74	Maximum effective current value
W75	Main circuit capacitor's capacitor
W76	Cumulative ope. time of capacitor on PC board
W77	Cumulative ope. time of cooling fan
W78	Number of startups
W79	Cumulative ope. time of motor driving
W80	Jugdement level of cooling fan
W81	Integrating electric power
W82	Data used integrating electric power
W83	Number of RS485 ch1 errors
W84	Contents of RS485 ch1 error
W85	Number of RS485 ch2 errors
W87	Remote keypad's ROM version
W89	Remote keypad's ROM version
W90	Option 1 ROM version
W94	Contents of RS485 ch2 error
W95	Number of option communication errors
W96	Option communicate error contents
[W-SigDataEnd]

[X-SigData]
X00	Alarm history (latest)
X01	Multiple alarm1 (latest)
X02	Multiple alarm2 (latest)
X03	Sub code
X05	Alarm history (last)
X06	Multiple alarm1 (last)
X07	Multiple alarm2 (last)
X08	Sub code
X10	Alarm history (second last)
X11	Multiple alarm1 (second last)
X12	Multiple alarm2 (second last)
X13	Sub code
X15	Alarm history (third last)
X16	Multiple alarm1 (third last)
X17	Multiple alarm2 (third last)
X18	Sub code
X20	Latest info. on alarm (output frequency)
X21	Latest info. on alarm (output current)
X22	Latest info. on alarm (output voltage)
X23	Latest info. on alarm (Truqe)
X24	Latest info. on alarm (set frequency)
X25	Latest info. on alarm (operation status)
X26	Latest info. on alarm (cumulative ope. time)
X27	Latest info. on alarm (number of startups)
X28	Latest info. on alarm (DC link circuit voltage)
X29	Latest info. on alarm (Heat sink maximum temperature)
X30	Latest info. on alarm (heat sink temperature)
X31	Latest info. on alarm (input terminal)
X32	Latest info. on alarm (output terminal)
X33	Latest info. on alarm (input terminal(com.))
X34	Latest info. on alarm (output terminal(com.))
X35	Last info. on alarm (Input power)
X60	Last info. on alarm (output frequency)
X61	Last info. on alarm (output current)
X62	Last info. on alarm (output voltage)
X63	Last info. on alarm (Truqe)
X64	Last info. on alarm (set frequency)
X65	Last info. on alarm (operation status)
X66	Last info. on alarm (cumulative ope. time)
X67	Last info. on alarm (number of startups)
X68	Last info. on alarm (DC link circuit voltage)
X69	Last info. on alarm (Heat sink maximum temperature)
X70	Last info. on alarm (heat sink temperature)
X71	Last info. on alarm (input terminal)
X72	Last info. on alarm (output terminal)
X73	Last info. on alarm (input terminal(com.))
X74	Last info. on alarm (output terminal(com.))
[X-SigDataEnd]

[Z-SigData]
Z00	Second last info. on alarm (output frequency)
Z01	Second last info. on alarm (output current)
Z02	Second last info. on alarm (output voltage)
Z03	Second last info. on alarm (Truqe)
Z04	Second last info. on alarm (set frequency)
Z05	Second last info. on alarm (operation status)
Z06	Second last info. on alarm (cumulative ope. time)
Z07	Second last info. on alarm (number of startups)
Z08	Second last info. on alarm (DC link circuit voltage)
Z09	Second Last info. on alarm (Heat sink maximum temperature)
Z10	Second last info. on alarm (heat sink temperature)
Z11	Second last info. on alarm (input terminal)
Z12	Second last info. on alarm (output terminal)
Z13	Second last info. on alarm (input terminal(com.))
Z14	Second last info. on alarm (output terminal(com.))
Z50	Third last info. on alarm (output frequency)
Z51	Third last info. on alarm (output current)
Z52	Third last info. on alarm (output voltage)
Z53	Third last info. on alarm (Truqe)
Z54	Third last info. on alarm (set frequency)
Z55	Third last info. on alarm (operation status)
Z56	Third last info. on alarm (cumulative ope. time)
Z57	Third last info. on alarm (number of startups)
Z58	Third last info. on alarm (DC link circuit voltage)
Z59	Third Last info. on alarm (Heat sink maximum temperature)
Z60	Third last info. on alarm (heat sink temperature)
Z61	Third last info. on alarm (input terminal)
Z62	Third last info. on alarm (output terminal)
Z63	Third last info. on alarm (input terminal(com.))
Z64	Third last info. on alarm (output terminal(com.))
[Z-SigDataEnd]