﻿[F-SigData]
F00	Data protection
F01	Frequency command 1
F02	Operation method
F03	Maximum frequency
F04	Base frequency
F05	Rated voltage (at base freqency)
F07	Acceleration time 1
F08	Deceleration time 1
F09	Torque boost
F10	Electronic thermal (Select the motor property)
F11	Electronic thermal (Overload detection level)
F12	Electronic thermal (Thermal time constant)
F14	Restart mode after momentary power failure (Select)
F15	Frequency limiter (Peak)
F16	Frequency limiter (Bottom)
F18	Bais frequency (for F01)
F20	DC brake (Starting frequency)
F21	DC brake (Braking level)
F22	DC brake (Braking time)
F23	Starting frequency
F25	Stop frequency
F26	Motor sound (Carrier frequency)
F27	Motor sound (Sound tone)
F30	FMA terminal (Output gain)
F31	FMA terminal (Monitor object)
F37	Load select/Auto torque boost/Energy-saving ope.
F43	Current limiter (Operation condition)
F44	Current limiter (Level)
F50	E-thermal [braking resistor] (Discharge capability)
F51	E-thermal [braking resistor] (Allowable loss)
[F-SigDataEnd]

[E-SigData]
E01	X1 terminal Command Assignment
E02	X2 terminal Command Assignment
E03	X3 terminal Command Assignment
E10	Acceleration time 2
E11	Deceleration time 2
E20	Y1 terminal Command Assignment
E27	30ABC Ry output Command Assignment
E31	Frequency detection [FDT] (Level)
E34	OL early warning/Current detection (Level)
E35	OL early warning/Current detection (Timer)
E39	Coefficient of constant rate of feeding time
E40	PID display coefficient A
E41	PID display coefficient B
E43	LED Monitor Item Selection
E48	LED Monitor (Speed monitor item)
E50	Coefficient for Speed Indication
E52	Keypad (Menu display mode)
E60	Potentiometer on the keypad (Function)
E61	12 terminal (Extension function select)
E62	C1 terminal (Extension function select)
E98	FWD terminal Command Assignment
E99	REV terminal Command Assignment
[E-SigDataEnd]

[C-SigData]
C01	Jump freqency 1
C02	Jump freqency 2
C03	Jump freqency 3
C04	Jump freqency (Hysteresis)
C05	Multi-step frequency setting 1
C06	Multi-step frequency setting 2
C07	Multi-step frequency setting 3
C08	Multi-step frequency setting 4
C09	Multi-step frequency setting 5
C10	Multi-step frequency setting 6
C11	Multi-step frequency setting 7
C20	Jogging frequency
C21	Timer operation (Mode select)
C30	Frequency command 2
C32	[12] Analog input adj. (Gain)
C33	[12] Analog input adj. (Filter)
C34	[12] Analog input adj. (Gain reference point)
C37	[C1] Analog input adj. (Gain)
C38	[C1] Analog input adj. (Filter)
C39	[C1] Analog input adj. (Gain reference point)
C50	Bias [Freq. command 1] (Bias reference point)
C51	Bais [PID command 1] (Bias value)
C52	Bais [PID command 1] (Bias reference point)
[C-SigDataEnd]

[P-SigData]
P02	Motor (Rated capacity)
P03	Motor (Rated current)
P09	Motor (Slip compensation gain)
P14	Motor (No-load current)
P99	Motor Selection
[P-SigDataEnd]

[H-SigData]
H03	Data initializing (Data reset)
H04	Retry (No. of retries)
H05	Retry (Latency time)
H06	Cooling Fan ON/OFF
H07	Gradual Acceleration/Deceleration
H12	Instantaneous overcurrent limiting (Specify operation)
H26	PTC Thermistor input (Specify operation)
H27	PTC Thermistor input (Level)
H30	Communication Link Operation (Function select)
H42	Capacitor of DC Link Bus Capcitor
H43	Accumulated Run time of Cooling Fan
H50	Non-linear V/f Pattern (Frequency)
H51	Non-linear V/f Pattern (Voltage)
H54	ACC/DEC time (Jogging operation)
H64	Bottom Limiter (Min.freq.when limiter is activated)
H69	Automatic deceleration (Specify operation)
H70	Overload prevention control (Frequency drop rate)
H80	Gain for suppression of Output Current Fluctuation
H95	DC brake (Breaking response mode)
H96	STOP key priority / Start check function
H97	Clear alarm data
H98	Protection/maintenance function (Specify operation)
[H-SigDataEnd]

[S-SigData]
S01	Frequency command (p.u.)
S05	Frequency command
S06	Operation command
S08	Acceleration time F07
S09	Deceleration time F09
S13	PID command
S14	Alarm reset command
[S-SigDataEnd]

[M-SigData]
M01	Frequency command (p.u.) (Final command)
M05	Frequency command (Final command)
M06	Output frequency 1(p.u.)
M09	Output frequency 1
M10	Input power
M11	Output current effective value
M12	Output voltage effective value
M13	Operation command (Final command)
M14	Operation status
M15	General-purpose output terminal information
M16	Latest contents of alarm
M17	Last contents of alarm
M18	Second last contents of alarm
M19	Third last contents of alarm
M20	Cumulative operation time
M21	DC link circuit voltage
M23	Model code
M24	Capacity code
M25	ROM version
M26	Transmission error transaction code
M27	Frequency command on alarm (p.u.)(Final command)
M31	Frequency command on alarm (Final command)
M32	Output frequency 1 on alarm (p.u.)
M35	Output frequency 1 on alarm
M36	Input power on alarm
M37	Output current effective value on alarm
M38	Output voltage effective value on alarm
M39	Operation command on alarm
M40	Operation status on alarm
M41	Output terminal information on alarm
M42	Cumulative operation time on alarm
M43	DC link circuit voltage on alarm
M45	Heat sink temperature on alarm
M46	Life of main circuit capacitor
M47	Life of PC board electrolytic capacitor
M48	Life of cooling fan
M49	Input terminal voltage[12] (p.u.)
M50	Input terminal current[C1] (p.u.)
M62	Heat sink temperature
M68	PID final command
M69	Inverter rated current
M70	Operation status 2
M71	Input terminal information (Operation command)
[M-SigDataEnd]

[J-SigData]
J01	PID control (Specify operation)
J02	PID control (Remote process command)
J03	PID control P (gain)
J04	PID control I (Integration time)
J05	PID control D (Differentiation time)
J06	PID control (Feedback filter)
[J-SigDataEnd]

[y-SigData]
y01	RS485 (Station address)
y02	RS485 (Mode select on no response error)
y03	RS485 (Timer)
y04	RS485 (Baud rate)
y05	RS485 (Data length)
y06	RS485 (Parity check)
y07	RS485 (Stop bits)
y08	RS485 (No response error detection time)
y09	RS485 (Response interval)
y10	RS485 (Protocol selection)
y99	Loader Link function for supporting data input
[y-SigDataEnd]

[W-SigData]
W01	Operation status
W02	Frequency command
W03	Output frequency (before slip compensation)
W04	Output frequency (after slip compensation)
W05	Output current
W06	Output voltage
W09	Load rotation speed
W10	Line speed
W11	PID process command
W12	PID feedback value
W17	Load speed set value
W18	Line speed set value
W19	Constant rate of feeding time set value
W20	Constant rate of feeding time
W21	Input power
W27	Timer operation remaining time
W28	Operation command source
W29	Frequency command source
W40	Control circuit terminal (input)
W41	Control circuit terminal (output)
W42	Communications control signal (input)
W43	Communications control signal (output)
W44	Terminal [12]input voltage
W45	Terminal [C1]input current
W46	FMA output voltage
W70	Cumulative operation time
W71	DC link circuit voltage
W73	Heat sink maximum temperature
W74	Maximum effective current value
W75	Main circuit capacitor's capacitor
W76	Cumulative ope. time of capacitor on PC board
W77	Cumulative ope. time of cooling fan
W78	Number of startups
W83	Number of RS485 errors
W84	Contents of RS485 error
W87	Inverter's ROM version
W89	Remote keypad's ROM version
[W-SigDataEnd]

[X-SigData]
X00	Alarm history (latest)
X01	Multiple alarm1 (latest)
X02	Multiple alarm2 (latest)
X05	Alarm history (last)
X06	Multiple alarm1 (last)
X07	Multiple alarm2 (last)
X10	Alarm history (second last)
X11	Multiple alarm1 (second last)
X12	Multiple alarm2 (second last)
X15	Alarm history (third last)
X16	Multiple alarm1 (third last)
X17	Multiple alarm2 (third last)
X20	Latest info. on alarm (output frequency)
X21	Latest info. on alarm (output current)
X22	Latest info. on alarm (output voltage)
X24	Latest info. on alarm (set frequency)
X25	Latest info. on alarm (operation status)
X26	Latest info. on alarm (cumulative ope. time)
X27	Latest info. on alarm (number of startups)
X28	Latest info. on alarm (DC link circuit voltage)
X30	Latest info. on alarm (heat sink temperature)
X31	Latest info. on alarm (input terminal)
X32	Latest info. on alarm (output terminal)
X33	Latest info. on alarm (input terminal(com.))
X34	Latest info. on alarm (output terminal(com.))
X60	Last info. on alarm (output frequency)
X61	Last info. on alarm (output current)
X62	Last info. on alarm (output voltage)
X64	Last info. on alarm (set frequency)
X65	Last info. on alarm (operation status)
X66	Last info. on alarm (cumulative ope. time)
X67	Last info. on alarm (number of startups)
X68	Last info. on alarm (DC link circuit voltage)
X70	Last info. on alarm (heat sink temperature)
X71	Last info. on alarm (input terminal)
X72	Last info. on alarm (output terminal)
X73	Last info. on alarm (input terminal(com.))
X74	Last info. on alarm (output terminal(com.))
[X-SigDataEnd]

[Z-SigData]
Z00	Second last info. on alarm (output frequency)
Z01	Second last info. on alarm (output current)
Z02	Second last info. on alarm (output voltage)
Z04	Second last info. on alarm (set frequency)
Z05	Second last info. on alarm (operation status)
Z06	Second last info. on alarm (cumulative ope. time)
Z07	Second last info. on alarm (number of startups)
Z08	Second last info. on alarm (DC link circuit voltage)
Z10	Second last info. on alarm (heat sink temperature)
Z11	Second last info. on alarm (input terminal)
Z12	Second last info. on alarm (output terminal)
Z13	Second last info. on alarm (input terminal(com.))
Z14	Second last info. on alarm (output terminal(com.))
Z50	Third last info. on alarm (output frequency)
Z51	Third last info. on alarm (output current)
Z52	Third last info. on alarm (output voltage)
Z54	Third last info. on alarm (set frequency)
Z55	Third last info. on alarm (operation status)
Z56	Third last info. on alarm (cumulative ope. time)
Z57	Third last info. on alarm (number of startups)
Z58	Third last info. on alarm (DC link circuit voltage)
Z60	Third last info. on alarm (heat sink temperature)
Z61	Third last info. on alarm (input terminal)
Z62	Third last info. on alarm (output terminal)
Z63	Third last info. on alarm (input terminal(com.))
Z64	Third last info. on alarm (output terminal(com.))
[Z-SigDataEnd]