﻿Series: SJ700
DataFormat=Hex

[SigData]
00001	Operation command
00002	Rotation direction command
00003	External trip (EXT)
00004	Trip reset (RS)
00007	Intelligent input terminal [1]
00008	Intelligent input terminal [2]
00009	Intelligent input terminal [3]
0000A	Intelligent input terminal [4]
0000B	Intelligent input terminal [5]
0000C	Intelligent input terminal [6]
0000D	Intelligent input terminal [7]
0000E	Intelligent input terminal [8]
0000F	Operation status
00010	Rotation direction
00011	Inverter ready
00013	RUN (running)
00014	FA1 (constant-speed reached)
00015	FA2 (set frequency overreached)
00016	OL (overload notice advance signal (1))
00017	OD (output deviation for PID control)
00018	AL (alarm signal)
00019	FA3 (set frequency reached)
0001A	OTQ (over-torque)
0001B	IP (instantaneous power failure)
0001C	UV (undervoltage)
0001D	TRQ (torque limited)
0001E	RNT (operation time over)
0001F	ONT (plug-in time over)
00020	THM (thermal alarm signal)
00026	BRK (brake release)
00027	BER (brake error)
00028	ZS (0 Hz detection signal)
00029	DSE (speed deviation maximum)
0002A	POK (positioning completed)
0002B	FA4 (set frequency overreached 2)
0002C	FA5 (set frequency reached 2)
0002D	OL2 (overload notice advance signal (2))
00032	FBV (PID feedback comparison)
00033	NDc (communication train disconnection)
00034	LOG1 (logical operation result 1)
00035	LOG2 (logical operation result 2)
00036	LOG3 (logical operation result 3)
00037	LOG4 (logical operation result 4)
00038	LOG5 (logical operation result 5)
00039	LOG6 (logical operation result 6)
0003A	WAC (capacitor life warning)
0003B	WAF (cooling-fan speed drop)
0003C	FR (starting contact signal)
0003D	OHF (heat sink overheat warning)
0003E	LOC (low-current indication signal)
0003F	M01 (general output 1)
00040	M02 (general output 2)
00041	M03 (general output 3)
00042	M04 (general output 4)
00043	M05 (general output 5)
00044	M06 (general output 6)
00045	IRDY (inverter ready)
00046	FWR (forward rotation)
00047	RVR (reverse rotation)
00048	MJA (major failure)
00049	Data writing in progress
0004A	CRC error
0004B	Overrun
0004C	Framing error
0004D	Parity error
0004E	Sum check error
40001	Frequency source setting (high)
40002	Frequency source setting (low)
40003	Inverter status A
40004	Inverter status B
40005	Inverter status C
40006	PID feedback
40011	Trip Counter
40012	Trip monitoring 1 (factor)
40013	Trip monitoring 1 (inverter status)
40014	Trip monitoring 1 (frequency) (high)
40015	Trip monitoring 1 (frequency) (low)
40016	Trip monitoring 1 (current)
40017	Trip monitoring 1 (voltage)
40018	Trip monitoring 1 (running time) (high)
40019	Trip monitoring 1 (running time) (low)
4001A	Trip monitoring 1 (power-on time) (high)
4001B	Trip monitoring 1 (power-on time) (low)
4001C	Trip monitoring 2 (factor)
4001D	Trip monitoring 2 (inverter status)
4001E	Trip monitoring 2 (frequency) (high)
4001F	Trip monitoring 2 (frequency) (low)
40020	Trip monitoring 2 (current)
40021	Trip monitoring 2 (voltage)
40022	Trip monitoring 2 (running time) (high)
40023	Trip monitoring 2 (running time) (low)
40024	Trip monitoring 2 (power-on time) (high)
40025	Trip monitoring 2 (power-on time) (low)
40026	Trip monitoring 3 (factor)
40027	Trip monitoring 3 (inverter status)
40028	Trip monitoring 3 (frequency) (high)
40029	Trip monitoring 3 (frequency) (low)
4002A	Trip monitoring 3 (current)
4002B	Trip monitoring 3 (voltage)
4002C	Trip monitoring 3 (running time) (high)
4002D	Trip monitoring 3 (running time) (low)
4002E	Trip monitoring 3 (power-on time) (high)
4002F	Trip monitoring 3 (power-on time) (low)
40030	Trip monitoring 4 (factor)
40031	Trip monitoring 4 (inverter status)
40032	Trip monitoring 4 (frequency) (high)
40033	Trip monitoring 4 (frequency) (low)
40034	Trip monitoring 4 (current)
40035	Trip monitoring 4 (voltage)
40036	Trip monitoring 4 (running time) (high)
40037	Trip monitoring 4 (running time) (low)
40038	Trip monitoring 4 (power-on time) (high)
40039	Trip monitoring 4 (power-on time) (low)
4003A	Trip monitoring 5 (factor)
4003B	Trip monitoring 5 (inverter status)
4003C	Trip monitoring 5 (frequency) (high)
4003D	Trip monitoring 5 (frequency) (low)
4003E	Trip monitoring 5 (current)
4003F	Trip monitoring 5 (voltage)
40040	Trip monitoring 5 (running time) (high)
40041	Trip monitoring 5 (running time) (low)
40042	Trip monitoring 5 (power-on time) (high)
40043	Trip monitoring 5 (power-on time) (low)
40044	Trip monitoring 6 (factor)
40045	Trip monitoring 6 (inverter status)
40046	Trip monitoring 6 (frequency) (high)
40047	Trip monitoring 6 (frequency) (low)
40048	Trip monitoring 6 (current)
40049	Trip monitoring 6 (voltage)
4004A	Trip monitoring 6 (running time) (high)
4004B	Trip monitoring 6 (running time) (low)
4004C	Trip monitoring 6 (power-on time) (high)
4004D	Trip monitoring 6 (power-on time) (low)
4004E	Programming error monitoring
40900	Writing to EEPROM
41001	Output frequency monitoring (high)
41002	Output frequency monitoring (low)
41003	Output current monitoring
41004	Rotation direction minitoring
41005	Process variable (PV), PID feedback monitoring (high)
41006	Process variable (PV), PID feedback monitoring (low)
41007	Intelligent input terminal status
41008	Intelligent output terminal status
41009	Scaled output frequency monitoring (high)
4100A	Scaled output frequency monitoring (low)
4100B	Actual-frequency monitoring (high)
4100C	Actual-frequency monitoring (low)
4100D	Torque command monitoring
4100E	Torque bias monitoring
41010	Torque monitoring
41011	Output voltage monitoring
41012	Power monitoring
41013	Cumulative power monitoring (high)
41014	Cumulative power monitoring (low)
41015	Cumulative operation RUN time monitoring (high)
41016	Cumulative operation RUN time monitoring (low)
41017	Cumulative power-on time monitoring (high)
41018	Cumulative power-on time monitoring (low)
41019	Heat sink temperature monitoring
4101A	Motor temperature monitoring
4101D	Life-check monitoring
41026	DC voltage monitoring (across P and N)
41027	BRD load factor monitoring
41028	Electronic thermal overload monitoring
41103	Acceleration (1) time setting (high)
41104	Acceleration (1) time setting (low)
41105	Deceleration (1) time setting (high)
41106	Deceleration (1) time setting (low)
41107	Keypad Run key routing
41201	Frequency source setting
41202	Run command source setting
41203	Base frequency setting
41204	Maximum frequency setting
41205	[AT] selection
41206	[O2] selection
4120B	[O]-[L] input active range start frequency (high)
4120C	[O]-[L] input active range start frequency (low)
4120D	[O]-[L] input active range end frequency (high)
4120E	[O]-[L] input active range end frequency (low)
4120F	[O]-[L] input active range start voltage
41210	[O]-[L] input active range end voltage
41211	[O]-[L] input active range start frequency selection
41212	External frequency filter time const.
41213	Easy sequence function selection
41215	Multispeed operation selection
41216	Multispeed frequency setting (high)
41217	Multispeed frequency setting (low)
41218	Multispeed 1 setting (high)
41219	Multispeed 1 setting (low)
4121A	Multispeed 2 setting (high)
4121B	Multispeed 2 setting (low)
4121C	Multispeed 3 setting (high)
4121D	Multispeed 3 setting (low)
4121E	Multispeed 4 setting (high)
4121F	Multispeed 4 setting (low)
41220	Multispeed 5 setting (high)
41221	Multispeed 5 setting (low)
41222	Multispeed 6 setting (high)
41223	Multispeed 6 setting (low)
41224	Multispeed 7 setting (high)
41225	Multispeed 7 setting (low)
41226	Multispeed 8 setting (high)
41227	Multispeed 8 setting (low)
41228	Multispeed 9 setting (high)
41229	Multispeed 9 setting (low)
4122A	Multispeed 10 setting (high)
4122B	Multispeed 10 setting (low)
4122C	Multispeed 11 setting (high)
4122D	Multispeed 11 setting (low)
4122E	Multispeed 12 setting (high)
4122F	Multispeed 12 setting (low)
41230	Multispeed 13 setting (high)
41231	Multispeed 13 setting (low)
41232	Multispeed 14 setting (high)
41233	Multispeed 14 setting (low)
41234	Multispeed 15 setting (high)
41235	Multispeed 15 setting (low)
41238	Jog frequency setting
41239	Jog stop mode
4123B	Torque boost method selection
4123C	Manual torque boost value
4123D	Manual torque boost frequency adjustment
4123E	V/F characteristic curve selection, 1st motor
4123F	V/f gain setting
41240	Voltage compensation gain setting for automatic torque boost, 1st motor
41241	Slippage compensation gain setting for automatic torque boost, 1st motor
41245	DC braking enable
41246	DC braking frequency setting
41247	DC braking wait time
41248	DC braking force during deceleration
41249	DC braking time for deceleration
4124A	DC braking/edge or level detection for [DB] input
4124B	DC braking force for starting
4124C	DC braking time for starting
4124D	DC braking carrier frequency setting
4124F	Frequency upper limit setting (high)
41250	Frequency upper limit setting (low)
41251	Frequency lower limit setting (high)
41252	Frequency lower limit setting (low)
41253	Jump (center) frequency setting 1 (high)
41254	Jump (center) frequency setting 1 (low)
41255	Jump (hysteresis) frequency width setting 1
41256	Jump (center) frequency setting 2 (high)
41257	Jump (center) frequency setting 2 (low)
41258	Jump (hysteresis) frequency width setting 2
41259	Jump (center) frequency setting 3 (high)
4125A	Jump (center) frequency setting 3 (low)
4125B	Jump (hysteresis) frequency width setting 3
4125C	Acceleration stop frequency setting (high)
4125D	Acceleration stop frequency setting (low)
4125E	Acceleration stop time frequency setting
4125F	PID Function Enable
41260	PID proportional gain
41261	PID integral time constant
41262	PID derivative gain
41263	PV scale conversion
41264	PV source setting
41265	Reverse PID
41266	PID output limiter
41269	AVR function select
4126A	AVR voltage select
4126D	Operation mode selection
4126E	Energy saving mode tuning
41274	Acceleration (2) time setting (high)
41275	Acceleration (2) time setting (low)
41276	Deceleration (2) time setting (high)
41277	Deceleration (2) time setting (low)
41278	Select method to switch to Acc2/Dec2 profile
41279	Acc1 to Acc2 frequency transition point (high)
4127A	Acc1 to Acc2 frequency transition point (low)
4127B	Dec1 to Dec2 frequency transition point (high)
4127C	Dec1 to Dec2 frequency transition point (low)
4127D	Acceleration curve selection
4127E	Deceleration curve setting
41281	[OI]-[L] input active range start frequency (high)
41282	[OI]-[L] input active range start frequency (low)
41283	[OI]-[L] input active range end frequency (high)
41284	[OI]-[L] input active range end frequency (low)
41285	[OI]-[L] input active range start current
41286	[OI]-[L] input active range end current
41287	[OI]-[L] input start frequency enable
4128D	[O2]-[L] input active range start frequency (high)
4128E	[O2]-[L] input active range start frequency (low)
4128F	[O2]-[L] input active range end frequency (high)
41290	[O2]-[L] input active range end frequency (low)
41291	[O2]-[L] input active range start voltage
41292	[O2]-[L] input active range end voltage
412A5	Acceleration curve constants setting
412A6	Deceleration curve constants setting
412AF	Operation-target frequency selection 1
412B0	Operation-target frequency selection 2
412B1	Operator selection
412B3	Frequency to be added (high)
412B4	Frequency to be added (low)
412B5	Sign of the frequency to be added
412B9	EL-S-curve acceleration/deceleration ratio 1
412BA	EL-S-curve acceleration/deceleration ratio 2
412BB	EL-S-curve deceleration/deceleration ratio 1
412BC	EL-S-curve deceleration/deceleration ratio 2
41301	Selection of restart mode
41302	Allowable under-voltage power failure time
41303	Retry wait time before motor restart
41304	Instantaneous power failure/under-voltage trip alarm enable
41305	Number of restarts on power failure/under-voltage trip events
41306	Phase loss detection enable
41307	Restart frequency threshold (high)
41308	Restart frequency threshold (low)
41309	Selection of retry after tripping
4130A	Selection of retry count after undervoltage
4130B	Selection of retry count after overvoltage or overcurrent
4130C	Retry wait time after tripping
4130D	Electronic thermal setting(calculated within the inverter from current output)
4130E	Electronic thermal characteristic
41310	Free setting, electronic thermal frequency (1)
41311	Free setting, electronic thermal current (1)
41312	Free setting, electronic thermal frequency (2)
41313	Free setting, electronic thermal current (2)
41314	Free setting, electronic thermal frequency (3)
41315	Free setting, electronic thermal current (3)
41316	Overload restriction operation mode
41317	Overload restriction setting
41318	Deceleration rate at overload restriction
41319	Overload restriction operation mode (2)
4131A	Overload restriction setting (2)
4131B	Deceleration rate at overload restriction (2)
4131C	Overcurrent suppression enable
4131D	Active frequency matching scan start frequency
4131E	Active frequency matching, scan-time constant
4131F	Active frequency matching, restart frequency select
41320	Software lock mode selection
41323	Run/power-on warning time (high)
41324	Run/power-on warning time (low)
41326	Reduced voltage start selection
41327	Function code display restriction
41328	Initial-screen selection
41329	Automatic user-parameter setting function enable
4132A	Torque limit selection
4132B	Torque limit (1) (forward-drivingin 4-quadrant mode)
4132C	Torque limit (2) (reverse-regenerating in 4-quadrant mode)
4132D	Torque limit (3) (reverse-driving in 4-quadrant mode)
4132E	Torque limit (4) (forward-regenerating in 4-quadrant mode)
4132F	Torque limit LADSTOP enable
41330	Reverse Run protection enable
41334	Controller deceleration and stop on power loss
41335	DC bus voltage trigger level during power loss
41336	Over-voltage threshold during power loss
41337	Deceleration time setting duringpower loss (target voltage level) (high)
41338	Deceleration time setting duringpower loss (target voltage level) (low)
41339	Initial output frequency decrease during power loss
41351	Cumulative input power data clearance
41352	Cumulative input power display gain setting
41355	Start frequency adjustment
41356	Carrier frequency setting
41357	Initialization mode (parameters or trip history)
41358	Country code for initialization
41359	Frequency scaling conversion factor
4135A	STOP key enable
4135B	Restart mode after FRS
4135D	Dynamic braking usage ratio
4135E	Stop mode selection
4135F	Cooling fan control
41362	Dynamic braking control
41363	Dynamic braking activation level
41365	Thermistor for thermal protection control
41366	Thermal protection level setting
41367	Free-setting V/f frequency (1)
41368	Free-setting V/f voltage (1)
41369	Free-setting V/f frequency (2)
4136A	Free-setting V/f voltage (2)
4136B	Free-setting V/f frequency (3)
4136C	Free-setting V/f voltage (3)
4136D	Free-setting V/f frequency (4)
4136E	Free-setting V/f voltage (4)
4136F	Free-setting V/f frequency (5)
41370	Free-setting V/f voltage (5)
41371	Free-setting V/f frequency (6)
41372	Free-setting V/f voltage (6)
41373	Free-setting V/f frequency (7)
41374	Free-setting V/f voltage (7)
4137B	Brake Control Enable
4137C	Brake Wait Time for Release
4137D	Brake Wait Time for Acceleration
4137E	Brake Wait Time for Stopping
4137F	Brake Wait Time for Confirmation
41380	Brake Release Frequency Setting
41381	Brake Release Current Setting
41382	Braking frequency
41385	Overvoltage suppression enable
41386	Overvoltage suppression level
41387	Acceleration and deceleration rate at overvoltage suppression
41401	Terminal [1] function
41402	Terminal [2] function
41403	Terminal [3] function
41404	Terminal [4] function
41405	Terminal [5] function
41406	Terminal [6] function
41407	Terminal [7] function
41408	Terminal [8] function
4140B	Terminal [1] active state
4140C	Terminal [2] active state
4140D	Terminal [3] active state
4140E	Terminal [4] active state
4140F	Terminal [5] active state
41410	Terminal [6] active state
41411	Terminal [7] active state
41412	Terminal [8] active state
41413	Terminal [FW] active state
41415	Terminal [11] function
41416	Terminal [12] function
41417	Terminal [13] function
41418	Terminal [14] function
41419	Terminal [15] function
4141A	Alarm relay terminal function
4141B	[FM] siginal selection
4141C	[AM] siginal selection
4141D	[AMI] siginal selection
4141E	Digital current monitor reference value
4141F	Terminal [11] active state
41420	Terminal [12] active state
41421	Terminal [13] active state
41422	Terminal [14] active state
41423	Terminal [15] active state
41424	Alarm relay active state
41426	Low-current indication signal output mode selection
41427	Low-current indication signal detection level
41428	Overload signal output mode
41429	Overload level setting
4142A	Frequency arrival setting for accel. (high)
4142B	Frequency arrival setting for accel. (low)
4142C	Frequency arrival setting for decel. (high)
4142D	Frequency arrival setting for decel. (low)
4142E	PID deviation level setting
4142F	Frequency arrival setting for acceleration (2) (high)
41430	Frequency arrival setting for acceleration (2) (low)
41431	Frequency arrival setting for deceleration (2) (high)
41432	Frequency arrival setting for deceleration (2) (low)
41438	Maximum PID feedback data
41439	Minimum PID feedback data
4143B	Over-torque (forward-driving) level setting
4143C	Over-torque (reverse regenerating) level setting
4143D	Over-torque (reverse driving) level setting
4143E	Over-torque (forward regenerating) level setting
41441	Electronic thermal warning level setting
41442	Alarm code output
41443	Zero speed detection level
41444	Heat sink overheat warning level
4144B	Communication speed selection
4144C	Node allocation
4144D	Communication data length selection
4144E	Communication parity selection
4144F	Communication stop bit selection
41450	Selection of the operation after communication error
41451	Communication timeout limit
41452	Communication wait time
41453	Communication mode selection
41455	[O] input span calibration
41456	[OI] input span calibration
41457	[O2] input span calibration
41459	Thermistor input tuning
4145F	Debug mode enable
41469	Up/Down memory mode selection
4146A	Reset mode selection
4146B	Restart mode after reset
4146D	FM gain adjustment
4146E	AM gain adjustment
4146F	AMI gain adjustment
41471	AM bias adjustment
41472	AMI bias adjustment
41473	Overload setting (2)
4147D	[O] input zero calibration
4147E	[OI] input zero calibration
4147F	[O2] input zero calibration
41486	Output 11 on-delay time
41487	Output 11 off-delay time
41488	Output 12 on-delay time
41489	Output 12 off-delay time
4148A	Output 13 on-delay time
4148B	Output 13 off-delay time
4148C	Output 14 on-delay time
4148D	Output 14 off-delay time
4148E	Output 15 on-delay time
4148F	Output 15 off-delay time
41490	Output RY on-delay time
41491	Output RY off-delay time
41492	Logical output signal 1 selection 1
41493	Logical output signal 1 selection 2
41494	Logical output signal 1 operator selection
41495	Logical output signal 2 selection 1
41496	Logical output signal 2 selection 2
41497	Logical output signal 2 operator selection
41498	Logical output signal 3 selection 1
41499	Logical output signal 3 selection 2
4149A	Logical output signal 3 operator selection
4149B	Logical output signal 4 selection 1
4149C	Logical output signal 4 selection 2
4149D	Logical output signal 4 operator selection
4149E	Logical output signal 5 selection 1
4149F	Logical output signal 5 selection 2
414A0	Logical output signal 5 operator selection
414A1	Logical output signal 6 selection 1
414A2	Logical output signal 6 selection 2
414A3	Logical output signal 6 operator selection
41501	Auto-tuning Setting
41502	Motor data selection, 1st motor
41503	Motor capacity, 1st motor
41504	Motor poles setting, 1st motor
41505	Motor speed constant, 1st motor (high)
41506	Motor speed constant, 1st motor (low)
41507	Motor stabilization constant, 1st motor
41515	Motor constant R1, 1st motor (high)
41516	Motor constant R1, 1st motor (low)
41517	Motor constant R2, 1st motor (high)
41518	Motor constant R2, 1st motor (low)
41519	Motor constant L, 1st motor (high)
4151A	Motor constant L, 1st motor (low)
4151B	Motor constant Io (high)
4151C	Motor constant Io (low)
4151D	Motor constant J (high)
4151E	Motor constant J (low)
41524	Auto constant R1, 1st motor (high)
41525	Auto constant R1, 1st motor (low)
41526	Auto constant R2, 1st motor (high)
41527	Auto constant R2, 1st motor (low)
41528	Auto constant L, 1st motor (high)
41529	Auto constant L, 1st motor (low)
4152A	Auto constant Io, 1st motor (high)
4152B	Auto constant Io, 1st motor (low)
4152C	Auto constant J, 1st motor (high)
4152D	Auto constant J, 1st motor (low)
4153D	PI proportional gain for 1st motor
4153E	PI integral gain for 1st motor
4153F	P proportional gain setting for 1st motor
41547	Zero LV lmit for 1st motor
41548	Zero LV starting boost current for 1st motor
41551	Terminal selection PI proportional gain setting
41552	Terminal selection PI integral gain setting
41553	Terminal selection P proportional gain setting
41554	Gain switching time
41601	Operation mode on expansion card 1 error
41602	Operation mode on expansion card 2 error
4160B	Encoder pulse-per-revolution (PPR) setting
4160C	Control pulse setting
4160D	Pulse train mode setting
4160E	Home search stop position setting
4160F	Home search speed setting
41610	Home search direction setting
41611	Home search completion range setting
41612	Home search completion delay time setting
41613	Electronic gear set position selection
41614	Electronic gear ratio numerator setting
41615	Electronic gear ratio denominator setting
41616	Feed-forward gain setting
41617	Position loop gain setting
41619	Temperature compensation thermistor enable
4161A	Over-speed error detection level setting
4161B	Speed deviation error detection level setting
4161C	Numerator of the motor gear ratio
4161D	Denominator of the motor gear ratio
4161F	Accel/decel time input selection
41620	Positioning command input selection
41621	Torque command input selection
41622	Torque command setting
41623	Polarity selection at the torque command input via O2 terminal
41624	Torque bias mode
41625	Torque bias value
41626	Torque bias polarity selection
41627	Speed limit for torque-controlled operation (forward rotation) (high)
41628	Speed limit for torque-controlled operation (forward rotation) (low)
41629	Speed limit for torque-controlled operation (reverse rotation) (high)
4162A	Speed limit for torque-controlled operation (reverse rotation) (low)
4162E	DeviceNet comm watchdog timer
4162F	Inverter action on DeviceNet comm error
41630	DeviceNet polled I/O: Output instance number
41631	DeviceNet polled I/O: Input instance number
41632	Inverter action on DeviceNet idle mode
41633	Motor poles setting for RPM
41639	Pulse train frequency scale
4163A	Time constant of pulse train frequency filter
4163B	Pulse train frequency bias
4163C	Pulse train frequency limit
41666	Easy sequence user parameter U (00)
41667	Easy sequence user parameter U (01)
41668	Easy sequence user parameter U (02)
41669	Easy sequence user parameter U (03)
4166A	Easy sequence user parameter U (04)
4166B	Easy sequence user parameter U (05)
4166C	Easy sequence user parameter U (06)
4166D	Easy sequence user parameter U (07)
4166E	Easy sequence user parameter U (08)
4166F	Easy sequence user parameter U (09)
41670	Easy sequence user parameter U (10)
41671	Easy sequence user parameter U (11)
41672	Easy sequence user parameter U (12)
41673	Easy sequence user parameter U (13)
41674	Easy sequence user parameter U (14)
41675	Easy sequence user parameter U (15)
41676	Easy sequence user parameter U (16)
41677	Easy sequence user parameter U (17)
41678	Easy sequence user parameter U (18)
41679	Easy sequence user parameter U (19)
4167A	Easy sequence user parameter U (20)
4167B	Easy sequence user parameter U (21)
4167C	Easy sequence user parameter U (22)
4167D	Easy sequence user parameter U (23)
4167E	Easy sequence user parameter U (24)
4167F	Easy sequence user parameter U (25)
41681	Easy sequence user parameter U (27)
41682	Easy sequence user parameter U (28)
41683	Easy sequence user parameter U (29)
41684	Easy sequence user parameter U (30)
41685	Easy sequence user parameter U (31)
42103	Acceleration (1) time setting, 2nd motor (high)
42104	Acceleration (1) time setting, 2nd motor (low)
42105	Deceleration time, 2nd motor (high)
42106	Deceleration time, 2nd motor (low)
42203	Base frequency setting, 2nd motor
42204	Maximum frequency setting, 2nd motor
42216	Multispeed frequency setting, 2nd motor (high)
42217	Multispeed frequency setting, 2nd motor (low)
4223B	Torque boost method selection, 2nd motor
4223C	Manual torque boost value, 2nd motor
4223D	Manual torque boost frequency adjustment, 2nd motor
4223E	V/F characteristic curve selection, 2nd motor
42240	Voltage compensation gain setting for automatic torque boost, 2nd motor
42241	Slippage compensation gain setting for automatic torque boost, 2nd motor
4224F	Frequency upper limit setting, 2nd motor (high)
42250	Frequency upper limit setting, 2nd motor (low)
42251	Frequency lower limit setting, 2nd motor (high)
42252	Frequency lower limit setting, 2nd motor (low)
4226F	Acceleration (2) time setting, 2nd motor (high)
42270	Acceleration (2) time setting, 2nd motor (low)
42271	Deceleration (2) time setting, 2nd motor (high)
42272	Deceleration (2) time setting, 2nd motor (low)
42273	Select method to switch to Acc2/Dec2, 2nd motor
42274	Acc1 to Acc2 frequency transition point, 2nd motor (high)
42275	Acc1 to Acc2 frequency transition point, 2nd motor (low)
42276	Dec1 to Dec2 frequency transition point, 2nd motor (high)
42277	Dec1 to Dec2 frequency transition point, 2nd motor (low)
4230C	Electronic thermal setting (calculated within the inverter from current output), 2nd motor
4230D	Electronic thermal characteristic, 2nd motor
42502	Motor data selection, 2nd motor
42503	Motor capacity, 2nd motor
42504	Motor poles setting, 2nd motor
42505	Motor speed constant, 2nd motor (high)
42506	Motor speed constant, 2nd motor (low)
42507	Motor stabilization constant, 2nd motor
42515	Motor constant R1, 2nd motor (high)
42516	Motor constant R1, 2nd motor (low)
42517	Motor constant R2, 2nd motor (high)
42518	Motor constant R2, 2nd motor (low)
42519	Motor constant L, 2nd motor (high)
4251A	Motor constant L, 2nd motor (low)
4251B	Motor constant Io, 2nd motor (high)
4251C	Motor constant Io, 2nd motor (low)
4251D	Motor constant J, 2nd motor (high)
4251E	Motor constant J, 2nd motor (low)
42524	Auto constant R1, 2nd motor (high)
42525	Auto constant R1, 2nd motor (low)
42526	Auto constant R2, 2nd motor (high)
42527	Auto constant R2, 2nd motor (low)
42528	Auto constant L, 2nd motor (high)
42529	Auto constant L, 2nd motor (low)
4252A	Auto constant Io, 2nd motor (high)
4252B	Auto constant Io, 2nd motor (low)
4252C	Auto constant J, 2nd motor (high)
4252D	Auto constant J, 2nd motor (low)
4253D	PI proportional gain for 2nd motor
4253E	PI integral gain for 2nd motor
4253F	P proportional gain setting for 2nd motor
42547	Zero LV lmit for 2nd motor
42548	Zero LV starting boost current for 2nd motor
43103	Acceleration (1) time setting, 3rd motor (high)
43104	Acceleration (1) time setting, 3rd motor (low)
43105	Deceleration (1) time setting, 3rd motor (high)
43106	Deceleration (1) time setting, 3rd motor (low)
43203	Base frequency setting, 3rd motor
43204	Maximum frequency setting, 3rd motor
43216	Multispeed frequency setting, 3rd motor (high)
43217	Multispeed frequency setting, 3rd motor (low)
4323C	Manual torque boost value, 3rd motor
4323D	Manual torque boost frequency adjustment, 3rd motor
4323E	V/F characteristic curve selection, 3rd motor
4326D	Acceleration (2) time setting, 3rd motor (high)
4326E	Acceleration (2) time setting, 3rd motor (low)
4326F	Deceleration (2) time setting, 3rd motor (high)
43270	Deceleration (2) time setting, 3rd motor (low)
4330C	Electronic thermal setting (calculated within the inverter from current output), 3rd motor
4330D	Electronic thermal characteristic, 3rd motor
43507	Motor stabilization constant, 3rd motor
[SigDataEnd]