﻿Series: FR-BB3(A500)
DataFormat=Dec

[P-SigData]
001	Maximum frequency
002	Minimum frequency
004	Multi-speed setting (high speed)
005	Multi-speed setting (middle speed)
006	Multi-speed setting (low speed)
007	Acceleration time
008	Deceleration time
009	Electronic thermal O/L relay
010	DC injection brake operation frequency
011	DC injection brake operation time
012	DC injection brake voltage
013	Starting frequency
015	Jog frequency
016	Jog acceleration/deceleration time
017	MRS input selection
018	High-speed maximum frequency
020	Acceleration/deceleration reference frequency
021	Acceleration/deceleration time increments
022	Stall prevention operation level
023	Stall prevention operation level compensation factor at double speed
024	Multi-speed setting (speed 4)
025	Multi-speed setting (speed 5)
026	Multi-speed setting (speed 6)
027	Multi-speed setting (speed 7)
028	Multi-speed input compensation
029	Acceleration/deceleration pattern
030	Regenerative function selection
031	Frequency jump 1A
032	Frequency jump 1B
033	Frequency jump 2A
034	Frequency jump 2B
035	Frequency jump 3A
036	Frequency jump 3B
037	Speed display
041	Up-to-frequency sensitivity
042	Output frequency detection
043	Output frequency detection for reverse rotation
044	Second acceleration/deceleration time
045	Second deceleration time
048	Second stall prevention operation current
049	Second stall prevention operation frequency
050	Second output frequency detection
052	DU/PU main display data selection
053	PU level display data selection
054	FM terminal function selection
055	Frequency monitoring reference
056	Current monitoring reference
057	Restart coasting time
058	Restart cushion time
059	Remote setting function selection
060	Intelligent mode selection
061	Reference I for intelligent mode
062	Ref. I for intelligent mode accel
063	Ref. I for intelligent mode decel
064	Starting frequency for elevator mode
065	Retry selection
066	Stall prevention operation level reduction starting frequency
067	Number of retries at alarm occurrence
068	Retry waiting time
069	Retry count display erasure
070	Special regenerative brake duty
071	Applied motor
072	PWM frequency selection
073	0-5V/0-10V selection
074	Filter time constant
075	Reset selection/disconnected PU detection/PU stop selection
076	Alarm code output selection
077	Parameter write disable selection
078	Reverse rotation prevention selection
079	Operation mode selection
080	Motor capacity
081	Number of motor poles
082	Motor exciting current
083	Rated motor voltage
084	Rated motor frequency
089	Speed control gain
090	Motor constant (R1)
091	Motor constant (R2)
092	Motor constant (L1)
093	Motor constant (L2)
094	Motor constant (X)
096	Auto-tuning setting/status
110	Third acceleration/deceleration time
111	Third deceleration time
114	Third stall prevention operation current
115	Third stall prevention operation frequency
116	Third output frequency detection
117	Station number
118	Communication speed
119	Stop bit length/data length
120	Parity check presence/absence
121	Number of communication retries
122	Communication check time interval
123	Waiting time setting
124	CR/LF presence/absence selection
128	PID action selection
129	PID proportional band
130	PID integral time
131	Upper limit
132	Lower limit
133	PID action set point for PU operation
134	PID differential time
135	Commercial power supply-inverter switch-over sequence output terminal selection
136	MC switch-over interlock time
137	Start waiting time
138	Commercial power supply-inverter switch-over selection at alarm occurrence
139	Automatic inverter-commercial power supply switch-over frequency
140	Backlash acceleration stopping frequency
141	Backlash acceleration stopping time
142	Backlash deceleration stopping frequency
143	Backlash deceleration stopping time
144	Speed setting switchover
145	Parameter unit language switch-over
148	Stall prevention operation level at 0V input
149	Stall prevention operation level at 10V input
150	Output current detection level
151	Output current detection period
152	Zero current detection level
153	Zero current detection period
154	Voltage reduction selection during stall prevention operation
155	RT signal activated condition
156	Stall prevention operation selection
157	OL signal waiting time
158	AM terminal function selection
160	User group read selection
162	Automatic restart after instantaneous power failure selection
163	First cushion time for restart
164	First cushion voltage for restart
165	Restart stall prevention operation level
170	Watt-hour meter clear
171	Actual operation hour meter clear
173	User group 1 registration
174	User group 1 deletion
175	User group 2 registration
176	User group 2 deletion
180	RL terminal function selection
181	RM terminal function selection
182	RH terminal function selection
183	RT terminal function selection
184	AU terminal function selection
185	JOG terminal function selection
186	CS terminal function selection
190	RUN terminal function selection
191	SU terminal function selection
192	IPF terminal function selection
193	OL terminal function selection
194	FU terminal function selection
195	A, B, C terminal function selection
199	User's initial value setting
200	Programmed operation minute/second selection
201	Program setting 1
202	Program setting 1
203	Program setting 1
204	Program setting 1
205	Program setting 1
206	Program setting 1
207	Program setting 1
208	Program setting 1
209	Program setting 1
210	Program setting 1
211	Program setting 2
212	Program setting 2
213	Program setting 2
214	Program setting 2
215	Program setting 2
216	Program setting 2
217	Program setting 2
218	Program setting 2
219	Program setting 2
220	Program setting 2
221	Program setting 3
222	Program setting 3
223	Program setting 3
224	Program setting 3
225	Program setting 3
226	Program setting 3
227	Program setting 3
228	Program setting 3
229	Program setting 3
230	Program setting 3
231	Timer setting
232	Multi-speed setting (speed 8)
233	Multi-speed setting (speed 9)
234	Multi-speed setting (speed 10)
235	Multi-speed setting (speed 11)
236	Multi-speed setting (speed 12)
237	Multi-speed setting (speed 13)
238	Multi-speed setting (speed 14)
239	Multi-speed setting (speed 15)
240	Soft-PWM setting
244	Cooling fan operation selection
250	Stop selection
251	Output phase failure protection selection
252	Override bias
253	Override gain
261	Power failure stop selection
262	Subtracted frequency at deceleration start
263	Subtraction starting frequency
264	Power-failure deceleration time 1
265	Power-failure deceleration time 2
266	Power-failure deceleration time switchover frequency
270	Stop-on-contact/load torque high-speed frequency control selection
271	High-speed setting maximum current
272	Mid-speed setting minimum current
273	Current averaging range
274	Current averaging filter constant
275	Stop-on-contact exciting current low-speed multiplying factor
276	Stop-on-contact PWM carrier frequency
278	Brake opening frequency
279	Brake opening current
280	Brake opening current detection time
281	Brake operation time at start
282	Brake operation frequency
283	Brake operation time at stop
284	Deceleration detection function selection
285	Overspeed detection frequency
286	Droop gain
287	Droop filter constant
300	BCD code input bias
301	BCD code input gain
302	Binary input bias
303	Binary input gain
304	Selection of whether digital input and analog compensation input are enabled or disabled
305	Data read timing signal on/off selection
306	Analog output signal selection
307	Setting for zero analog output
308	Setting for maximum analog output
309	Analog output signal voltage/current switch-over
310	Analog meter voltage output selection
311	Setting for zero analog meter voltage output
312	Setting for maximum analog meter voltage output
313	Y0 output selection
314	Y1 output selection
315	Y2 output selection
316	Y3 output selection
317	Y4 output selection
318	Y5 output selection
319	Y6 output selection
320	RA1 output selection
321	RA2 output selection
322	RA3 output selection
330	RA output selection
331	Inverter station number
332	Communication speed
333	Stop bit length
334	Parity check yes/no
335	Communication retry count
336	Communication check time interval
337	Waiting time setting
338	Operation command right
339	Speed command right
340	Link startup mode selection
341	CR, LF yes/no selection
342	EEPROM write selection
900	FM terminal calibration
901	AM terminal calibration
902	Frequency setting voltage bias
903	Frequency setting voltage gain
904	Frequency setting current bias
905	Frequency setting current gain
990	PU Buzzer control
991	LCD contrast
[P-SigDataEnd]

[S-SigData]
S00	Operation mode
S01	Output frequency[speed]
S02	Output current
S03	Output voltage
S04	Special monitor
S05	Special monitor selection No.
S06	Output frequency
S07	Output current
S08	Output voltage
S09	Frequency setting
S10	Running speed
S11	Motor torque
S13	Regenerative brake
S14	Electronic overcurrent protection load factor
S15	Output current peak value
S16	Converter output voltage peak value
S17	Input power
S18	Output power
S43	Alarm definition (Latest Nos. 1&2)
S44	Alarm definition (Latest Nos. 3&4)
S45	Alarm definition (Latest Nos. 5&6)
S46	Alarm definition (Latest Nos. 7&8)
S48	Run command
S48.01	Forward rotation (STF)
S48.02	Reverse rotation (STR)
S50	Inverter status monitor
S50.00	Inverter running (RUN)
S50.01	Forward rotation
S50.02	Reverse rotation
S50.03	Up to frequency (SU)
S50.04	Overload (OL)
S50.05	Instantaneous power failure (IPF)
S50.06	Frequency detection (FU)
S50.07	Alarm occurrence
S51	Set frequency read (RAM) 
S52	Set frequency read (EEPROM) 
S53	Set frequency write (RAM) 
S54	Set frequency write (EEPROM)
S55	Inverter reset
S56	Alarm definition batch clear
S57	All clear/User clear
S58	Link parameter expansion setting
S59	Second parameter changing
[S-SigDataEnd]