﻿Series: FR-F700
DataFormat=Dec

[P-SigData]
000	Torque boost
001	Maximum frequency
002	Minimum frequency
003	Base frequency
004	Multi-speed setting (high speed)
005	Multi-speed setting (middle speed)
006	Multi-speed setting (low speed)
007	Acceleration time
008	Deceleration time
009	Electronic thermal O/L relay
010	DC injection brake operation frequency
011	DC injection brake operation time
012	DC injection brake operation voltage
013	Starting frequency
014	Load pattern selection
015	Jog frequency
016	Jog acceleration/deceleration time
017	MRS input selection
018	High speed maximum frequency
019	Base frequency voltage
020	Acceleration/deceleration reference frequency
021	Acceleration/deceleration time increments
022	Stall prevention operation level (Torque limit level )
023	Stall prevention operation level compensation factor at double speed
024	Multi-speed setting (speed 4)
025	Multi-speed setting (speed 5)
026	Multi-speed setting (speed 6)
027	Multi-speed setting (speed 7)
028	Multi-speed input compensation selection
029	Acceleration/deceleration pattern selection
030	Regenerative function selection
031	Frequency jump 1A
032	Frequency jump 1B
033	Frequency jump 2A
034	Frequency jump 2B
035	Frequency jump 3A
036	Frequency jump 3B
037	Speed display
041	Up-to-frequency sensitivity
042	Output frequency detection
043	Output frequency detection for reverse rotation
044	Second acceleration/deceleration time
045	Second deceleration time
046	Second torque boost
047	Second V/F (base frequency)
048	Second stall prevention operation current
049	Second stall prevention operation frequency
050	Second output frequency detection
051	Second electronic thermal O/L relay
052	DU/PU main display data selection
054	FM terminal function selection
055	Frequency monitoring reference
056	Current monitoring reference
057	Restart coasting time
058	Restart cushion time
059	Remote function selection
060	Energy saving control selection
061	Reference current
062	Reference value at acceleration
063	Reference value at dcceleration
064	Starting frequency for elevator mode
065	Retry selection
066	Stall prevention operation reduction starting frequency
067	Number of retries at alarm occurrence
068	Retry waiting time
069	Retry count display erase
070	Special regenerative brake duty
071	Applied motor
072	PWM frequency selection
073	Analog input selection
074	Input filter time constant
075	Reset selection/disconnected PU detection/PU stop selection
076	Alarm code output selection
077	Parameter write selection
078	Reverse rotation prevention selection
079	Operation mode selection
080	Motor capacity
090	Motor constant (R1)
100	V/F1 (first frequency)
101	V/F1 (first frequency voltage)
102	V/F2 (second frequency)
103	V/F2 (second frequency voltage)
104	V/F3 (third frequency)
105	V/F3 (third frequency voltage)
106	V/F4 (fourth frequency)
107	V/F4 (fourth frequency voltage)
108	V/F5 (fifth frequency)
109	V/F5 (fifth frequency voltage)
117	PU communication station number
118	PU communication speed
119	PU communication stop bit length
120	PU communication parity check
121	Number of PU communication retries
122	PU communication check time interval
123	PU communication waiting time setting
124	PU communication CR/LF presence/absence selection
125	Terminal 2 frequency setting gain frequency
126	Terminal 4 frequency setting gain frequency
127	PID control automatic switchover freqeuncy
128	PID action selection
129	PID proportional band
130	PID integral time
131	PID upper limit
132	PID lower limit
133	PID action set point
134	PID differential time
135	Electronic bypass sequence selection
136	MC switchover interlock time
137	Start waiting time
138	Bypass selection at an alarm
139	Automatic switchover frequency from inverter to bypass operation
140	Backlash acceleration stopping frequency
141	Backlash acceleration stopping time
142	Backlash deceleration stopping frequency
143	Backlash deceleration stopping time
144	Speed setting switchover
145	PU display language selection
148	Stall prevention level at 0V input
149	Stall prevention level at 10V input
150	Output current detection level
151	Output current detection signal delay time
152	Zero current detection level
153	Zero current detection time
154	Voltage reduction selection during stall prevention operation
155	RT signal function validity condition selection
156	Stall prevention operation selection
157	OL signal output timer
158	AM terminal function selection
159	Automatic switchover frequency range from bypass to inverter operation
160	User group read selection
161	Frequency setting/key lock operation selection
162	Automatic restart after instantaneous power failure selection
163	First cushion time for restart
164	First cushion voltage for restart
165	Stall prevention operation level for restart
166	Output current detection signal retention time
167	Output current detection operation selection
170	Watt-hour meter clear
171	Operation hour meter clear
172	User group registered display/batch clear
173	User group registration
174	User group clear
178	STF terminal function selection
179	STR terminal function selection
180	RL terminal function selection
181	RM terminal function selection
182	RH terminal function selection
183	RT terminal function selection
184	AU terminal function selection
185	JOG terminal function selection
186	CS terminal function selection
187	MRS terminal function selection
188	STOP terminal function selection
189	RES terminal function selection
190	RUN terminal function selection
191	SU terminal function selection
192	IPF terminal function selection
193	OL terminal function selection
194	FU terminal function selection
195	ABC1 terminal function selection
196	ABC2 terminal function selection
232	Multi-speed setting (speed 8)
233	Multi-speed setting (speed 9)
234	Multi-speed setting (speed 10)
235	Multi-speed setting (speed 11)
236	Multi-speed setting (speed 12)
237	Multi-speed setting (speed 13)
238	Multi-speed setting (speed 14)
239	Multi-speed setting (speed 15)
240	Soft-PWM operation selection
241	Analog input display unit switchover
242	Terminal 1 added compensation amount (terminal 2)
243	Terminal 1 added compensation amount (terminal 4)
244	Cooling fan operation selection
245	Rated slip
246	Slip compensation time constant
247	Constant-power region slip compensation selection
250	Stop selection
251	Output phase failure protection selection
252	Override bias
253	Override gain
255	Life alarm status display
256	Inrush current limit circuit life display
257	Control circuit capacitor life display
258	Main circuit capacitor life display
259	Main circuit capacitor life measuring
260	PWM frequency automatic switchover
261	Power failure stop selection
262	Subtracted frequency at deceleration start
263	Subtraction starting frequency
264	Power-failure deceleration time 1
265	Power-failure deceleration time 2
266	Power failure deceleration time switchover frequency
267	Terminal 4 input selection
268	Monitor decimal digits selection
299	Rotation direction detection selection at restarting
300	BCD input bias
301	BCD input gain
302	BIN input bias
303	BIN input gain
304	Digital input and analog input compensation enable/disable selection
305	Read timing operation selection
306	Analog output signal selection
307	Setting for zero analog output
308	Setting for maximum analog output
309	Analog output signal voltage/current switchover
310	Analog meter voltage output selection
311	Setting for zero analog meter voltage output
312	Setting for maximum analog meter voltage output
313	DO0 output selection
314	DO1 output selection
315	DO2 output selection
316	DO3 output selection
317	DO4 output selection
318	DO5 output selection
319	DO6 output selection
320	RA1 output selection
321	RA2 output selection
322	RA3 output selection
323	AM0 0V adjustment
324	AM1 0mA adjustment
329	Digital input unit selection
331	RS-485 communication station
332	RS-485 communication speed
333	RS-485 communication stop bit length
334	RS-485 communication parity check selection
335	RS-485 communication retry count
336	RS-485 communication check time interval
337	RS-485 communication waiting time setting
338	Communication operation command source
339	Communication speed command source
340	Communication startup mode selection
341	RS-485 communication CR/LF selection
342	Communication EEPROM write selection
343	Communication error count
345	DeviceNet address
346	DeviceNet baud rate
349	Communication reset selection
387	Initial communication delay time
388	Send time interval at hart beat
389	Minimum sending time at hart beat
390	% setting reference frequency
391	Receive time interval at hart beat
392	Event driven detection width
495	Remote output selection
496	Remote output data 1
497	Remote output data 2
500	Communication error execution waiting time
501	Communication error occurrence count display
502	Stop mode selection at communication error
503	Maintenance timer
504	Maintenance timer alarm output set time
539	Modbus-RTU communication check time interval
542	Communication station number (CC-Link)
543	Baud rate (CC-Link)
544	CC-Link extended setting
549	Protocol selection
550	NET mode operation command source selection
551	PU mode operation command source selection
555	Current average time
556	Data output mask time
557	Current average value monitor signal output reference current
563	Energization time carrying-over times
564	Operating time carrying-over times
571	Holding time at a start
575	Output interruption detection time
576	Output interruption detection level
577	Output interruption cancel level
611	Acceleration time at a restart
867	AM output filter
872	Input phase failure protection selection
882	Regeneration avoidance operation selection
883	Regeneration avoidance operation level
884	Regeneration avoidance at deceleration detection sensitivity
885	Regeneration avoidance compensation frequency limit value
886	Regeneration avoidance voltage gain
888	Free parameter 1
889	Free parameter 2
891	Cumulative power monitor digit shifted times
892	Load factor
893	Energy saving monitor reference (motor capacity)
894	Control selection during commercial power-supply operation
895	Power saving rate reference value
896	Power unit cost
897	Power saving monitor average time
898	Power saving cumulative monitor clear
899	Operation time rate (estimated value)
900	(C0)FM terminal calibration
901	(C1)AM terminal calibration
902	(C2)Terminal 2 frequency setting bias frequency/(C3)Terminal 2 frequency setting bias
903	(125)Terminal 2 frequency setting gain frequency/(C4)Terminal 2 frequency setting gain
904	(C5)Terminal 4 frequency setting bias frequency/(C6)Terminal 4 frequency setting bias
905	(126)Terminal 4 frequency setting gain frequency/(C7)Terminal 4 frequency setting gain
989	Parameter copy alarm release
990	PU buzzer control
991	PU contrast adjustment
[P-SigDataEnd]

[S-SigData]
S00	Operation mode
S01	Output frequency/speed
S02	Output current
S03	Output voltage
S04	Special monitor
S05	Special monitor selection No.
S06	Output frequency
S07	Output current
S08	Output voltage
S09	Frequency setting
S10	Running speed
S12	Converter output voltage
S13	Regenerative brake duty
S14	Electronic thermal relay function load factor
S15	Output current peak value
S16	Converter output voltage peak value
S17	Input power
S18	Output power
S19	Input terminal status
S19.00	STF
S19.01	STR
S19.02	AU
S19.03	RT
S19.04	RL
S19.05	RM
S19.06	RH
S19.07	JOG
S19.08	MRS
S19.09	STOP
S19.10	RES
S19.11	CS
S20	Output terminal status
S20.00	RUN
S20.01	SU
S20.02	IPF
S20.03	OL
S20.04	FU
S20.05	ABC1
S20.06	ABC2
S21	Load meter
S24	Cumulative energization time
S26	Actual operation time
S27	Motor load factor
S28	Cumulative power
S33	Power saving effect
S34	Cumulative saving power
S35	PID set point
S36	PID measured value
S37	PID deviation value
S43	Alarm definition (Latest Nos. 1&2)
S44	Alarm definition (Latest Nos. 3&4)
S45	Alarm definition (Latest Nos. 5&6)
S46	Alarm definition (Latest Nos. 7&8)
S47	Run command (extended)
S47.00	AU (current input selection)
S47.01	Forward rotation command
S47.02	Reverse rotation command
S47.03	RL (low speed operation command)
S47.04	RM (middle speed operation command)
S47.05	RH (high speed operation command)
S47.06	RT (second function selection)
S47.07	MRS (output stop)
S47.08	JOG (Jog operation)
S47.09	CS (selection of automatic restart after instantaneous power failure)
S47.10	STOP (start self-holding)
S47.11	RES (reset)
S48	Run command
S48.00	AU (current input selection)
S48.01	Forward rotation command
S48.02	Reverse rotation command
S48.03	RL (low speed operation command)
S48.04	RM (middle speed operation command)
S48.05	RH (high speed operation command)
S48.06	RT (second function selection)
S48.07	MRS (output stop)
S49	Inverter status monitor (extended)
S49.00	RUN (inverter running)
S49.01	Forward rotation
S49.02	Reverse rotation
S49.03	SU (up to frequency)
S49.04	OL (overload)
S49.05	IPF (instantaneous power failure)
S49.06	FU (frequency detection)
S49.07	ABC1 (alarm) 
S49.08	ABC2
S49.15	Alarm occurrence
S50	Inverter status monitor
S50.00	RUN (inverter running)
S50.01	Forward rotation
S50.02	Reverse rotation
S50.03	SU (up to frequency)
S50.04	OL (overload)
S50.05	IPF (instantaneous power failure)
S50.06	FU (frequency detection)
S50.07	ABC1 (alarm)
S51	Set frequency read (RAM)
S52	Set frequency read (EEPROM)
S53	Set frequency write (RAM)
S54	Set frequency write (RAM, EEPROM)
S55	Inverter reset
S56	Alarm definition all clear
S57	All parameter clear
S58	Link parameter extended setting
S59	Second parameter changing
[S-SigDataEnd]