﻿Series: FR-S500
DataFormat=Dec

[P-SigData]
000	Torque boost
001	Maximum frequency
002	Minimum frequency
003	Base frequency
004	Multi-speed setting (high speed)
005	Multi-speed setting (middle speed)
006	Multi-speed setting (low speed)
007	Acceleration time
008	Deceleration time
009	Electronic thermal O/L relay
010	DC injection brake operation frequency
011	DC injection brake operation time
012	DC injection brake voltage
013	Starting frequency
014	Load pattern selection
015	Jog frequency
016	Jog acceleration/deceleration time
017	RUN key rotation direction selection
019	Base frequency voltage
020	Acceleration/deceleration reference frequency
021	Stall prevention function selection
022	Stall prevention operation level
023	Stall prevention operation level compensation factor at double speed
024	Multi-speed setting (speed 4)
025	Multi-speed setting (speed 5)
026	Multi-speed setting (speed 6)
027	Multi-speed setting (speed 7)
028	Stall prevention operation reduction starting frequency
029	Acceleration/deceleration pattern
030	Extended function display selection
031	Frequency jump 1A
032	Frequency jump 1B
033	Frequency jump 2A
034	Frequency jump 2B
035	Frequency jump 3A
036	Frequency jump 3B
037	Speed display
038	Frequency setting voltage gain frequency
039	Frequency setting current gain frequency
040	Start-time ground fault detection selection
041	Up-to-frequency sensitivity
042	Output frequency detection
043	Output frequency detection for reverse rotation
044	Second acceleration/deceleration time
045	Second deceleration time
046	Second torque boost
047	Second V/F (base frequency)
048	Output current detection level
049	Output current detection signal delay time
050	Zero current detection level
051	Zero current detection time
052	Control panel display data selection
053	Frequency setting operation selection
054	FM (AM) terminal function selection
055	Frequency monitoring reference
056	Current monitoring reference
057	Restart coasting time
058	Restart cushion time
059	Remote setting function selection/Frequency setting storage function selection
060	RL terminal function selection
061	RM terminal function selection
062	RH terminal function selection
063	STR terminal function selection
064	RUN terminal function selection
065	A, B, C terminal function selection
066	Retry selection
067	Number of retries at alarm occurrence
068	Retry waiting time
069	Retry count display erase
070	Soft-PWM setting
071	Applied motor
072	PWM frequency selection
073	0-5V/0-10V selection
074	Input filter time constant
075	Reset selection/PU stop selection
076	Cooling fan operation selection
077	Parameter write disable selection
078	Reverse rotation prevention selection
079	Operation mode selection
080	Multi-speed setting (speed 8)
081	Multi-speed setting (speed 9)
082	Multi-speed setting (speed 10)
083	Multi-speed setting (speed 11)
084	Multi-speed setting (speed 12)
085	Multi-speed setting (speed 13)
086	Multi-speed setting (speed 14)
087	Multi-speed setting (speed 15)
088	PID action selection
089	PID proportional band
090	PID integral time
091	PID upper limit
092	PID lower limit
093	PID action set point for PU operation
094	PID differential time
095	Rated motor slip
096	Slip compensation time constant
097	Constant-output region slip compensation selection
098	Automatic torque boost selection (Motor capacity)
099	Motor primary resistance
145	(n13)PU display language
162	(H6)Automatic restart after instantaneous power failure selection
331	(n1)Communication station number
332	(n2)Communication speed
333	(n3)Stop bit length
334	(n4)Parity check presence/absence
335	(n5)Number of communication retries
336	(n6)Communication check time interval
337	(n7)Wait time setting
338	(n8)Operation command write
339	(n9)Speed command write
340	(n10)Link start mode selection
341	(n11)CR/LF selection
342	(n12)EEPROM write selection
343	(n18)Communication error count
344	(n19)Protocol selection
345	(n20)Communication error check time
346	(n21)Communication reset selection
503	(H1)Maintenance timer
504	(H2)Maintenance timer alarm output set time
555	(H3)Current average time
556	(H4)Data output mask time
557	(H5)Current average value monitor signal output reference current
559	(H7)Second electronic thermal O/L relay
560	(b1)Regenerative function selection
561	(b2)Special regenerative brake duty
562	(H9)Multi-speed reference frequency
900	(C1)FM terminal calibration
901	(C1)AM terminal calibration
902	(C2)Frequency setting voltage bias frequency/(C3)Frequency setting voltage bias
903	(C4)Frequency setting voltage gain
904	(C5)Frequency setting current bias frequency/(C6)Frequency setting current bias
905	(C7)Frequency setting current gain
990	(n14)PU buzzer sound control
991	(n15)PU contrast adjustment
992	(n16)PU main display screen data selection
993	(n17)PU disconnection detection/PU setting lock
[P-SigDataEnd]

[S-SigData]
S00	Operation mode
S01	Output frequency[speed]
S02	Output current
S43	Alarm definition (Latest Nos. 1&2)
S44	Alarm definition (Latest Nos. 3&4)
S48	Run command
S48.01	Forward rotation (STF)
S48.02	Reverse rotation (STR)
S48.03	Low speed (RL)
S48.04	Middle speed (RM)
S48.05	High speed (RH)
S50	Inverter status monitor
S50.00	Inverter running (RUN)
S50.01	Forward rotation
S50.02	Reverse rotation
S50.03	Up to frequency (SU)
S50.04	Overload (OL)
S50.06	Frequency detection (FU)
S50.07	Alarm occurrence
S51	Set frequency read (RAM)
S52	Set frequency read (EEPROM)
S53	Set frequency write (RAM)
S54	Set frequency write (RAM,EEPROM)
S55	Inverter reset
S56	Alarm definition batch clear
S57	All parameter clear
S58	Link parameter expansion setting
S59	Second parameter changing
[S-SigDataEnd]

[SL-SigData]
SL01	Output frequency[speed]
SL51	Set frequency read (RAM)
SL52	Set frequency read (EEPROM)
SL53	Set frequency write (RAM)
SL54	Set frequency write (RAM,EEPROM)
[SL-SigDataEnd]