﻿//E5_N
MaxSigCnt=148
DataFormat=Hex

[C0-SigData]
C00000	PV
C00001	Status
C00002	Internal set point
C00003	Heater current 1 value monitor
C00004	MV monitor (heating)
C00005	MV monitor (cooling)
C00006	Heater current value 2 monitor
C00007	Leakage current value 1 monitor
C00008	Leakage current value 2 monitor
C00009	Soak time remain monitor
[C0-SigDataEnd]

[C1-SigData]
C10000	Operation/adjustment protect
C10001	Initial setting/communications protect
C10002	Setup change protection
C10003	Set point
C10004	Alarm value 1
C10005	Upper-limit alarm 1
C10006	Lower-limit alarm 1
C10007	Alarm value 2
C10008	Upper-limit alarm 2
C10009	Lower-limit alarm 2
C1000A	Alarm value 3
C1000B	Upper-limit alarm value 3
C1000C	Lower-limit alarm value 3
C1000D	Heater burnout 1 detection
C1000E	Set point 0
C1000F	Set point 1
C10010	Set point 2
C10011	Set point 3
C10012	Temperature input shift value
C10013	Upper-limit temperature input shift value
C10014	Lower-limit temperature input shift value
C10015	Proportional band
C10016	Integral time
C10017	Derivative time
C10018	Cooling coefficient
C10019	Dead band
C1001A	Manual reset value
C1001B	Hysteresis (heating)
C1001C	Hysteresis (cooling)
C1001D	Heater burnout 2 detection
C1001E	HS alarm 1
C1001F	HS alarm 2
C10020	Soak time
C10021	Wait band
C10022	MV at stop
C10023	MV at PV error
C10024	Manual manipulated variable
C10025	SP ramp set value
C10026	MV upper limit
C10027	MV lower limit
C10028	Move protect level
C10029	Password to move to protect level
C1002A	Parameter mask enable
[C1-SigDataEnd]

[C3-SigData]
C30000	Input type
C30001	Scaling upper limit
C30002	Scaling lower limit
C30003	Decimal point position
C30004	Temperature unit
C30005	SP upper limit
C30006	SP lower limit
C30007	PID/OnOff
C30008	Standard or heating and cooling
C30009	ST
C3000A	Control period (heat)
C3000B	Control period (cool)
C3000C	Direct/reverse operation
C3000D	Alarm 1 type
C3000E	Alarm 2 type
C3000F	Alarm 3 type
C30010	Communications unit number
C30011	Communications baud rate
C30012	Communications data length
C30013	Communications stop bits
C30014	Communications parity
C30015	Number of multi-SP uses
C30016	Event input assignment 1
C30017	Event input assignment 2
C3001A	Multi-SP usage
C3001B	SP ramp time unit
C3001C	SP ramp set value
C3001D	Standby sequence reset
C3001E	Alarm 1 open in alarm
C3001F	Alarm 1 hysteresis
C30020	Alarm 2 open in alarm
C30021	Alarm 2 hysteresis
C30022	Alarm 3 open in alarm
C30023	Alarm 3 hysteresis
C30024	HB ON/OFF
C30025	Heater burnout latch
C30026	Heater burnout hysteresis
C30027	ST stable range
C30028	Alpha
C30029	MV upper limit
C3002A	MV lower limit
C3002B	Input digital filter
C3002C	Additional PV display
C3002D	MV display
C3002E	Automatic display return time
C3002F	Alarm 1 latch
C30030	Alarm 2 latch
C30031	Alarm 3 latch
C30032	Protect level move time
C30033	Input error output
C30034	Cold junction compensation method
C30035	MB command logic switching
C30036	PV change color
C30037	PV stable band
C30038	Alarm 1 ON delay
C30039	Alarm 2 ON delay
C3003A	Alarm 3 ON delay
C3003B	Alarm 1 OFF delay
C3003C	Alarm 2 OFF delay
C3003D	Alarm 3 OFF delay
C3003E	Transfer output type
C3003F	Transfer output upper limit
C30040	Transfer output lower limit
C30041	Linear current output
C30042	Input shift type
C30043	MV at stop and error addition
C30044	Auto/manual switching display addition
C30045	RT
C30046	HS alarm
C30047	HS alarm latch
C30048	HS alarm hysteresis
C30049	LBA detection time
C3004A	LBA level
C3004B	LBA band
C3004C	Protocol Setting
C3004D	Send data wait time
C3004E	Control output 1 assignment
C3004F	Control output 2 assignment
C30050	Alarm 1 assignment
C30051	Alarm 2 assignment
C30052	Display character switch
C30053	Program pattern
C30054	Soak time units
C30055	Alarm SP selection
C30056	Alarm 3 assignment
[C3-SigDataEnd]

[A-SigData]
A0000	Communications writing
A0001	RUN/STOP
A0002	Multi-SP
A0003	AT execute/cancel
A0004	Write mode
A0005	Save RAM data
A0006	Software reset
A0007	Move to setup area 1
A0008	Move to protect level
A0009	Auto/manual switch
A000B	Parameter initialization
A0011	Program start
[A-SigDataEnd]

[C0-SigData]-B
C00000	    PV
C00001.00  Heater overcurrent (CT1)
C00001.01  Heater current hold (CT1)
C00001.02  HB (heater burnout) error
C00001.03  HS alarm output (CT1)
C00001.05  Display range exceeded
C00001.06  Input error
C00001.08  Control output (heating)
C00001.09  Control output (cooling)
C00001.10  HB (heater burnout) alarm output (CT1)
C00001.11  HB (heater burnout) alarm output (CT2)
C00001.12  Alarm output 1
C00001.13  Alarm output 2
C00001.14  Alarm output 3
C00001.15  Program end output
C00001.16  Event input 1
C00001.17  Event input 2
C00001.20  Write mode
C00001.21  EEPROM
C00001.22  Setup area
C00001.23  AT execute/cancel
C00001.24  RUN/STOP
C00001.25  Communications writing
C00001.26  Auto/manual switch
C00001.28  Heater overcurrent (CT2)
C00001.29  Heater current hold (CT2)
C00001.31  HS alarm output (CT2)
C00002	    Internal set point
C00003	    Heater current 1 value monitor
C00004	    MV monitor (heating)
C00005	    MV monitor (cooling)
C00006	    Heater current value 2 monitor
C00007	    Leakage current value 1 monitor
C00008	    Leakage current value 2 monitor
C00009	    Soak time remain monitor
[C0-SigDataEnd]-B