﻿Name=PLC1
SRZ
MaxSigCnt=
DataFormat=Hex

[SigData]
0000		Error code (Z-COM module)
0000.0		SRAM error/Adjustment data error (Error code (Z-COM module))
0000.1		Data back-up error (Error code (Z-COM module))
0000.2		A/D conversion error (Error code (Z-COM module))
0000.5		Logic output data error (Error code (Z-COM module))
0000.6		Stack overflow (Error code (Z-COM module))
0001-0064	Error code (Function module)   CH1-CH100
0001.0-0064.0	Adjustment data error (Error code (Function module))   CH1-CH100
0001.1-0064.1	Data back-up error (Error code (Function module))   CH1-CH100
0001.2-0064.2	A/D conversion error (Error code (Function module))   CH1-CH100
0001.5-0064.5	Logic output data error (Error code (Function module))   CH1-CH100
0065		Backup memory state monitor (Z-COM module)
0066-00C9	Backup memory state monitor (Function module)   CH1-CH100
00CA		System communication state
00CA.0		Data collection condition
00CB		SRZ normal communication flag
00CC		PLC communication error code
00CC.0		PLC register read/write error (PLC communication error code)
00CC.1		Slave communication timeout (PLC communication error code)
00CC.3		Internal communication error (PLC communication error code)
00CC.4		Master communication timeout (PLC communication error code)
00CD		Unit recognition flag
00CD.0		SRZ unit 1 (Unit recognition flag)
00CD.1		SRZ unit 2 (Unit recognition flag)
00CD.2		SRZ unit 3 (Unit recognition flag)
00CD.3		SRZ unit 4 (Unit recognition flag)
0132		Monitor for the number of connected modules
0133		RUN/STOP transfer (Each unit)
0134-0197	RUN/STOP transfer (Each module)   CH1-CH100
0198-01FB	Control RUN/STOP holding setting (Each module)   CH1-CH100
01FC-023B	Measured value (PV)   CH1-CH64
023C-027B	Comprehensive event state   CH1-CH64
023C.0-027B.0	Event 1 (Comprehensive event state)   CH1-CH64
023C.1-027B.1	Event 2 (Comprehensive event state)   CH1-CH64
023C.2-027B.2	Event 3 (Comprehensive event state)   CH1-CH64
023C.3-027B.3	Event 4 (Comprehensive event state)   CH1-CH64
023C.4-027B.4	Heater break alarm (Comprehensive event state)   CH1-CH64
023C.5-027B.5	Temperature rise completion (Comprehensive event state)   CH1-CH64
023C.6-027B.6	Burnout (Comprehensive event state)   CH1-CH64
027C-02BB	Operation mode state monitor   CH1-CH64
027C.0-02BB.0	Control STOP (Operation mode state monitor)   CH1-CH64
027C.1-02BB.1	Control RUN (Operation mode state monitor)   CH1-CH64
027C.2-02BB.2	Manual mode (Operation mode state monitor)   CH1-CH64
027C.3-02BB.3	Remote mode (Operation mode state monitor)   CH1-CH64
02CC-030B	Manipulated output value (MV) monitor [heat-side]   CH1-CH64
030C-034B	Manipulated output value (MV) monitor [cool-side]   CH1-CH64
034C-038B	Current transformer (CT) input value monitor   CH1-CH64
038C-03CB	Set value (SV) monitor   CH1-CH64
03CC-040B	Remote setting (RS) input value monitor   CH1-CH64
040C-044B	Burnout state monitor   CH1-CH64
044C-048B	Event 1 state monitor   CH1-CH64
048C-04CB	Event 2 state monitor   CH1-CH64
04CC-050B	Event 3 state monitor   CH1-CH64
050C-054B	Event 4 state monitor   CH1-CH64
054C-058B	Heater break alarm (HBA) state monitor   CH1-CH64
058C-059B	Output state monitor   CH1-CH16
058C.0-059B.0	OUT1 (Output state monitor)   CH1-CH16
058C.1-059B.1	OUT2 (Output state monitor)   CH1-CH16
058C.2-059B.2	OUT3 (Output state monitor)   CH1-CH16
058C.3-059B.3	OUT4 (Output state monitor)   CH1-CH16
059C-05DB	Memory area soak time monitor   CH1-CH64
05EC-062B	Holding peak value ambient temperature monitor   CH1-CH64
063C-064B	Logic output monitor 1   CH1-CH16
063C.0-064B.0	Logic output 1 (Logic output monitor 1)   CH1-CH16
063C.1-064B.1	Logic output 2 (Logic output monitor 1)   CH1-CH16
063C.2-064B.2	Logic output 3 (Logic output monitor 1)   CH1-CH16
063C.3-064B.3	Logic output 4 (Logic output monitor 1)   CH1-CH16
063C.4-064B.4	Logic output 5 (Logic output monitor 1)   CH1-CH16
063C.5-064B.5	Logic output 6 (Logic output monitor 1)   CH1-CH16
063C.6-064B.6	Logic output 7 (Logic output monitor 1)   CH1-CH16
063C.7-064B.7	Logic output 8 (Logic output monitor 1)   CH1-CH16
080C-084B	PID/AT transfer   CH1-CH64
084C-088B	Auto/Manual transfer   CH1-CH64
088C-08CB	Remote/Local transfer   CH1-CH64
08DC-091B	Memory area transfer   CH1-CH64
091C-095B	Interlock release   CH1-CH64
095C-099B	Event 1 set value (EV1)   CH1-CH64
099C-09DB	Event 2 set value (EV2)   CH1-CH64
09DC-0A1B	Event 3 set value (EV3)   CH1-CH64
0A1C-0A5B	Event 4 set value (EV4)   CH1-CH64
0A5C-0A9B	Control loop break alarm (LBA) time   CH1-CH64
0A9C-0ADB	LBA deadband   CH1-CH64
0ADC-0B1B	Set value (SV)   CH1-CH64
0B1C-0B5B	Proportional band [heat-side]   CH1-CH64
0B5C-0B9B	Integral time [heat-side]   CH1-CH64
0B9C-0BDB	Derivative time [heat-side]   CH1-CH64
0BDC-0C1B	Control response parameter   CH1-CH64
0C1C-0C5B	Proportional band [cool-side]   CH1-CH64
0C5C-0C9B	Integral time [cool-side]   CH1-CH64
0C9C-0CDB	Derivative time [cool-side]   CH1-CH64
0CDC-0D1B	Overlap/Deadband   CH1-CH64
0D1C-0D5B	Manual reset   CH1-CH64
0D5C-0D9B	Setting change rate limiter (up)   CH1-CH64
0D9C-0DDB	Setting change rate limiter (down)   CH1-CH64
0DDC-0E1B	Area soak time   CH1-CH64
0E1C-0E5B	Link area number   CH1-CH64
0E5C-0E9B	Heater break alarm (HBA) set value   CH1-CH64
0E9C-0EDB	Heater break determination point   CH1-CH64
0EDC-0F1B	Heater melting determination point   CH1-CH64
0F1C-0F5B	PV bias   CH1-CH64
0F5C-0F9B	PV digital filter   CH1-CH64
0F9C-0FDB	PV ratio   CH1-CH64
0FDC-101B	PV low input cut-off   CH1-CH64
101C-105B	RS bias   CH1-CH64
105C-109B	RS digital filter   CH1-CH64
109C-10DB	RS ratio   CH1-CH64
10DC-111B	Output distribution selection   CH1-CH64
111C-115B	Output distribution bias   CH1-CH64
115C-119B	Output distribution ratio   CH1-CH64
119C-11DB	Proportional cycle time   CH1-CH64
11DC-121B	Minimum ON/OFF time of proportioning cycle   CH1-CH64
121C-125B	Manual manipulated output value   CH1-CH64
125C-129B	Area soak time stop function   CH1-CH64
129C-12DB	EDS mode (for disturbance 1)   CH1-CH64
12DC-131B	EDS mode (for disturbance 2)   CH1-CH64
131C-135B	EDS value 1 (for disturbance 1)   CH1-CH64
135C-139B	EDS value 1 (for disturbance 2)   CH1-CH64
139C-13DB	EDS value 2 (for disturbance 1)   CH1-CH64
13DC-141B	EDS value 2 (for disturbance 2)   CH1-CH64
141C-145B	EDS transfer time (for disturbance 1)   CH1-CH64
145C-149B	EDS transfer time (for disturbance 2)   CH1-CH64
149C-14DB	EDS action time (for disturbance 1)   CH1-CH64
14DC-151B	EDS action time (for disturbance 2)   CH1-CH64
151C-155B	EDS action wait time (for disturbance 1)   CH1-CH64
155C-159B	EDS action wait time (for disturbance 2)   CH1-CH64
159C-15DB	EDS value learning times   CH1-CH64
15DC-161B	EDS start signal   CH1-CH64
161C-165B	Operation mode   CH1-CH64
165C-169B	Startup tuning (ST)   CH1-CH64
169C-16DB	Automatic temperature rise learning   CH1-CH64
16DC-16EB	Communication switch for logic   CH1-CH16
16DC.0-16EB.0	Communication switch 1 (Communication switch for logic)   CH1-CH16
16DC.1-16EB.1	Communication switch 2 (Communication switch for logic)   CH1-CH16
16DC.2-16EB.2	Communication switch 3 (Communication switch for logic)   CH1-CH16
16DC.3-16EB.3	Communication switch 4 (Communication switch for logic)   CH1-CH16
196C-19AB	Input type   CH1-CH64
19AC-19EB	Display unit   CH1-CH64
19EC-1A2B	Decimal point position   CH1-CH64
1A2C-1A6B	Input scale high   CH1-CH64
1A6C-1AAB	Input scale low   CH1-CH64
1AAC-1AEB	Input error determination point (high)   CH1-CH64
1AEC-1B2B	Input error determination point (low)   CH1-CH64
1B2C-1B6B	Burnout direction   CH1-CH64
1B6C-1BAB	Square root extraction   CH1-CH64
1BAC-1BEB	Output assignment (Logic output selection function)   CH1-CH64
1BEC-1C2B	Energized/ De-energized (Logic output selection function)   CH1-CH64
1C2C-1C6B	Event 1 type   CH1-CH64
1C6C-1CAB	Event 1 channel setting   CH1-CH64
1CAC-1CEB	Event 1 hold action   CH1-CH64
1CEC-1D2B	Event 1 interlock   CH1-CH64
1D2C-1D6B	Event 1 differential gap   CH1-CH64
1D6C-1DAB	Event 1 delay timer   CH1-CH64
1DAC-1DEB	Force ON of Event 1 action   CH1-CH64
1DAC.0-1DEB.0	Event output turned on at input error occurrence (Force ON of Event 1 action)   CH1-CH64
1DAC.1-1DEB.1	Event output turned on in manual mode (Force ON of Event 1 action)   CH1-CH64
1DAC.2-1DEB.2	Event output turned on during the autotuning (AT) function is being executed (Force ON of Event 1 action)   CH1-CH64
1DAC.3-1DEB.3	Event output turned on during the setting change rate limiter is being operated (Force ON of Event 1 action)   CH1-CH64
1DEC-1E2B	Event 2 type   CH1-CH64
1E2C-1E6B	Event 2 channel setting   CH1-CH64
1E6C-1EAB	Event 2 hold action   CH1-CH64
1EAC-1EEB	Event 2 interlock   CH1-CH64
1EEC-1F2B	Event 2 differential gap   CH1-CH64
1F2C-1F6B	Event 2 delay timer   CH1-CH64
1F6C-1FAB	Force ON of Event 2 action   CH1-CH64
1F6C.0-1FAB.0	Event output turned on at input error occurrence (Force ON of Event 2 action)   CH1-CH64
1F6C.1-1FAB.1	Event output turned on in manual mode (Force ON of Event 2 action)   CH1-CH64
1F6C.2-1FAB.2	Event output turned on during the autotuning (AT) function is being executed (Force ON of Event 2 action)   CH1-CH64
1F6C.3-1FAB.3	Event output turned on during the setting change rate limiter is being operated (Force ON of Event 2 action)   CH1-CH64
1FAC-1FEB	Event 3 type   CH1-CH64
1FEC-202B	Event 3 channel setting   CH1-CH64
202C-206B	Event 3 hold action   CH1-CH64
206C-20AB	Event 3 interlock   CH1-CH64
20AC-20EB	Event 3 differential gap   CH1-CH64
20EC-212B	Event 3 delay timer   CH1-CH64
212C-216B	Force ON of Event 3 action   CH1-CH64
212C.0-216B.0	Event output turned on at input error occurrence (Force ON of Event 3 action)   CH1-CH64
212C.1-216B.1	Event output turned on in manual mode (Force ON of Event 3 action)   CH1-CH64
212C.2-216B.2	Event output turned on during the autotuning (AT) function is being executed (Force ON of Event 3 action)   CH1-CH64
212C.3-216B.3	Event output turned on during the setting change rate limiter is being operated (Force ON of Event 3 action)   CH1-CH64
216C-21AB	Event 4 type   CH1-CH64
21AC-21EB	Event 4 channel setting   CH1-CH64
21EC-222B	Event 4 hold action   CH1-CH64
222C-226B	Event 4 interlock   CH1-CH64
226C-22AB	Event 4 differential gap   CH1-CH64
22AC-22EB	Event 4 delay timer   CH1-CH64
22EC-232B	Force ON of Event 4 action   CH1-CH64
22EC.0-232B.0	Event output turned on at input error occurrence (Force ON of Event 4 action)   CH1-CH64
22EC.1-232B.1	Event output turned on in manual mode (Force ON of Event 4 action)   CH1-CH64
22EC.2-232B.2	Event output turned on during the autotuning (AT) function is being executed (Force ON of Event 4 action)   CH1-CH64
22EC.3-232B.3	Event output turned on during the setting change rate limiter is being operated (Force ON of Event 4 action)   CH1-CH64
232C-236B	CT ratio   CH1-CH64
236C-23AB	CT assignment   CH1-CH64
23AC-23EB	Heater break alarm (HBA) type   CH1-CH64
23EC-242B	Number of heater break alarm (HBA) delay times   CH1-CH64
242C-246B	Hot/Cold start   CH1-CH64
246C-24AB	Start determination point   CH1-CH64
24AC-24EB	SV tracking   CH1-CH64
24EC-252B	MV transfer function [Action taken when changed to Manual mode from Auto mode]   CH1-CH64
252C-256B	Control action   CH1-CH64
256C-25AB	Integral/derivative time decimal point position   CH1-CH64
25AC-25EB	Derivative action   CH1-CH64
25EC-262B	Undershoot suppression factor   CH1-CH64
262C-266B	Derivative gain   CH1-CH64
266C-26AB	ON/OFF action differential gap (upper)   CH1-CH64
26AC-26EB	ON/OFF action differential gap (lower)   CH1-CH64
26EC-272B	Action (high) at input error   CH1-CH64
272C-276B	Action (low) at input error   CH1-CH64
276C-27AB	Manipulated output value at input error   CH1-CH64
27AC-27EB	Manipulated output value at STOP mode [heat-side]   CH1-CH64
27EC-282B	Manipulated output value at STOP mode [cool-side]   CH1-CH64
282C-286B	Output change rate limiter (up) [heat-side]   CH1-CH64
286C-28AB	Output change rate limiter (down) [heat-side]   CH1-CH64
28AC-28EB	Output limiter (high) [heat-side]   CH1-CH64
28EC-292B	Output limiter (low) [heat-side]   CH1-CH64
292C-296B	Output change rate limiter (up) [cool-side]   CH1-CH64
296C-29AB	Output change rate limiter (down) [cool-side]   CH1-CH64
29AC-29EB	Output limiter (high) [cool-side]   CH1-CH64
29EC-2A2B	Output limiter (low) [cool-side]   CH1-CH64
2A2C-2A6B	AT bias   CH1-CH64
2A6C-2AAB	AT cycles   CH1-CH64
2AAC-2AEB	Output value with AT turned on   CH1-CH64
2AEC-2B2B	Output value with AT turned off   CH1-CH64
2B2C-2B6B	AT differential gap time   CH1-CH64
2B6C-2BAB	Proportional band adjusting factor [heat-side]   CH1-CH64
2BAC-2BEB	Integral time adjusting factor [heat-side]   CH1-CH64
2BEC-2C2B	Derivative time adjusting factor [heat-side]   CH1-CH64
2C2C-2C6B	Proportional band adjusting factor [cool-side]   CH1-CH64
2C6C-2CAB	Integral time adjusting factor [cool-side]   CH1-CH64
2CAC-2CEB	Derivative time adjusting factor [cool-side]   CH1-CH64
2CEC-2D2B	Proportional band limiter (high) [heat-side]   CH1-CH64
2D2C-2D6B	Proportional band limiter (low) [heat-side]   CH1-CH64
2D6C-2DAB	Integral time limiter (high) [heat-side]   CH1-CH64
2DAC-2DEB	Integral time limiter (low) [heat-side]   CH1-CH64
2DEC-2E2B	Derivative time limiter (high) [heat-side]   CH1-CH64
2E2C-2E6B	Derivative time limiter (low) [heat-side]   CH1-CH64
2E6C-2EAB	Proportional band limiter (high) [cool-side]   CH1-CH64
2EAC-2EEB	Proportional band limiter (low) [cool-side]   CH1-CH64
2EEC-2F2B	Integral time limiter (high) [cool-side]   CH1-CH64
2F2C-2F6B	Integral time limiter (low) [cool-side]   CH1-CH64
2F6C-2FAB	Derivative time limiter (high) [cool-side]   CH1-CH64
2FAC-2FEB	Derivative time limiter (low) [cool-side]   CH1-CH64
2FEC-302B	Open/Close output neutral zone   CH1-CH64
302C-306B	Action at feedback resistance (FBR) input error   CH1-CH64
306C-30AB	Feedback adjustment   CH1-CH64
30AC-30EB	Control motor time   CH1-CH64
30EC-312B	Integrated output limiter   CH1-CH64
312C-316B	Valve action at STOP   CH1-CH64
316C-31AB	ST proportional band adjusting factor   CH1-CH64
31AC-31EB	ST integral time adjusting factor   CH1-CH64
31EC-322B	ST derivative time adjusting factor   CH1-CH64
322C-326B	ST start condition   CH1-CH64
326C-32AB	Automatic temperature rise group   CH1-CH64
32AC-32EB	Automatic temperature rise dead time   CH1-CH64
32EC-332B	Automatic temperature rise gradient data   CH1-CH64
332C-336B	EDS transfer time decimal point position   CH1-CH64
336C-33AB	Output average processing time for EDS   CH1-CH64
33AC-33EB	Responsive action trigger point for EDS   CH1-CH64
33EC-342B	Setting change rate limiter unit time   CH1-CH64
342C-346B	Soak time unit   CH1-CH64
346C-34AB	Setting limiter (high)   CH1-CH64
34AC-34EB	Setting limiter (low)   CH1-CH64
34EC-352B	PV transfer function   CH1-CH64
352C-356B	Operation mode assignment 1 (Logic output selection function) Logic output 1 to 4   CH1-CH64
356C-35AB	Operation mode assignment 2 (Logic output selection function) Logic output 5 to 8   CH1-CH64
35AC-35EB	SV select function   CH1-CH64
35EC-362B	Remote SV function master channel module address   CH1-CH64
362C-366B	Remote SV function master channel selection   CH1-CH64
366C-36AB	Output distribution master channel module address   CH1-CH64
36AC-36EB	Output distribution master channel selection   CH1-CH64
36EC-372B	Address of interacting modules   CH1-CH64
372C-376B	Channel selection of interacting modules   CH1-CH64
376C-37AB	Selection switch of interacting modules   CH1-CH64
376C.0-37AB.0	Memory area number (Selection switch of interacting modules)   CH1-CH64
376C.1-37AB.1	Operation mode (Selection switch of interacting modules)   CH1-CH64
376C.2-37AB.2	Auto/Manual (Selection switch of interacting modules)   CH1-CH64
376C.3-37AB.3	Remote/Local (Selection switch of interacting modules)   CH1-CH64
376C.4-37AB.4	EDS start signal (Selection switch of interacting modules)   CH1-CH64
376C.5-37AB.5	Interlock release (Selection switch of interacting modules)   CH1-CH64
376C.6-37AB.6	Suspension of area soak time (Selection switch of interacting modules)   CH1-CH64
37AC-37BB	TIO Interval time   CH1-CH16
386C-38AB	Setting memory area number   CH1-CH64
38AC-38EB	Event 1 set value (EV1)   CH1-CH64
38EC-392B	Event 2 set value (EV2)   CH1-CH64
392C-396B	Event 3 set value (EV3)   CH1-CH64
396C-39AB	Event 4 set value (EV4)   CH1-CH64
39AC-39EB	Control loop break alarm (LBA) time   CH1-CH64
39EC-3A2B	LBA deadband   CH1-CH64
3A2C-3A6B	Set value (SV)   CH1-CH64
3A6C-3AAB	Proportional band [heat-side]   CH1-CH64
3AAC-3AEB	Integral time [heat-side]   CH1-CH64
3AEC-3B2B	Derivative time [heat-side]   CH1-CH64
3B2C-3B6B	Control response parameter   CH1-CH64
3B6C-3BAB	Proportional band [cool-side]   CH1-CH64
3BAC-3BEB	Integral time [cool-side]   CH1-CH64
3BEC-3C2B	Derivative time [cool-side]   CH1-CH64
3C2C-3C6B	Overlap/Deadband   CH1-CH64
3C6C-3CAB	Manual reset   CH1-CH64
3CAC-3CEB	Setting change rate limiter (up)   CH1-CH64
3CEC-3D2B	Setting change rate limiter (down)   CH1-CH64
3D2C-3D6B	Area soak time   CH1-CH64
3D6C-3DAB	Link area number   CH1-CH64
3E6C-3E7B	Digital input (DI) state 1   CH1-CH16
3E6C.0-3E7B.0	DI1 (Digital input (DI) state 1)   CH1-CH16
3E6C.1-3E7B.1	DI2 (Digital input (DI) state 1)   CH1-CH16
3E6C.2-3E7B.2	DI3 (Digital input (DI) state 1)   CH1-CH16
3E6C.3-3E7B.3	DI4 (Digital input (DI) state 1)   CH1-CH16
3E6C.4-3E7B.4	DI5 (Digital input (DI) state 1)   CH1-CH16
3E6C.5-3E7B.5	DI6 (Digital input (DI) state 1)   CH1-CH16
3E6C.6-3E7B.6	DI7 (Digital input (DI) state 1)   CH1-CH16
3E6C.7-3E7B.7	DI8 (Digital input (DI) state 1)   CH1-CH16
3E7C-3E8B	Digital output (DO) state 1   CH1-CH16
3E7C.0-3E8B.0	DO1 (Digital output (DO) state 1)   CH1-CH16
3E7C.1-3E8B.1	DO2 (Digital output (DO) state 1)   CH1-CH16
3E7C.2-3E8B.2	DO3 (Digital output (DO) state 1)   CH1-CH16
3E7C.3-3E8B.3	DO4 (Digital output (DO) state 1)   CH1-CH16
3E7C.4-3E8B.4	DO5 (Digital output (DO) state 1)   CH1-CH16
3E7C.5-3E8B.5	DO6 (Digital output (DO) state 1)   CH1-CH16
3E7C.6-3E8B.6	DO7 (Digital output (DO) state 1)   CH1-CH16
3E7C.7-3E8B.7	DO8 (Digital output (DO) state 1)   CH1-CH16
3FDC-3FEB	DO manual output 1   CH1-CH16
3FDC.0-3FEB.0	DO1 manual output (DO manual output 1)   CH1-CH16
3FDC.1-3FEB.1	DO2 manual output (DO manual output 1)   CH1-CH16
3FDC.2-3FEB.2	DO3 manual output (DO manual output 1)   CH1-CH16
3FDC.3-3FEB.3	DO4 manual output (DO manual output 1)   CH1-CH16
3FDC.4-3FEB.4	DO5 manual output (DO manual output 1)   CH1-CH16
3FDC.5-3FEB.5	DO6 manual output (DO manual output 1)   CH1-CH16
3FDC.6-3FEB.6	DO7 manual output (DO manual output 1)   CH1-CH16
3FDC.7-3FEB.7	DO8 manual output (DO manual output 1)   CH1-CH16
3FEC-406B	DO output distribution selection   CH1-CH128
406C-40EB	DO output distribution bias   CH1-CH128
40EC-416B	DO output distribution ratio   CH1-CH128
416C-41EB	DO proportional cycle time   CH1-CH128
41EC-426B	DO minimum ON/OFF time of proportioning cycle   CH1-CH128
433C-434B	DI function assignment   CH1-CH16
434C-435B	Memory area setting signal   CH1-CH16
435C-436B	DO signal assignment module address 1   CH1-CH16
436C-437B	DO signal assignment module address 2   CH1-CH16
437C-438B	DO output assignment 1 [DO1 to DO4]   CH1-CH16
438C-439B	DO output assignment 2 [DO5 to DO8]   CH1-CH16
439C-441B	DO energized/de-energized   CH1-CH128
441C-449B	DO output distribution  master channel module address   CH1-CH128
449C-451B	DO output distribution  master channel selection   CH1-CH128
451C-459B	DO manipulated output value (MV) at STOP mode   CH1-CH128
459C-461B	DO output limiter (high)   CH1-CH128
461C-469B	DO output limiter (low)   CH1-CH128
469C-46AB	Z-DIO Interval time   CH1-CH16
46BC-477B	Current transformer (CT) input value monitor   CH1-CH192
477C-483B	Load factor conversion  CT monitor   CH1-CH192
483C-48FB	Heater break alarm (HBA) state monitor   CH1-CH192
48FC-49BB	Heater overcurrent alarm state monitor   CH1-CH192
49BC-49CB	Automatic setting state monitor   CH1-CH16
4FCC-508B	Heater break/Heater overcurrent alarm automatic setting selection   CH1-CH192
508C-514B	Automatic setting transfer   CH1-CH192
514C-520B	Heater break alarm (HBA) set value   CH1-CH192
520C-52CB	Heater break alarm (HBA) selection   CH1-CH192
52CC-538B	Heater overcurrent alarm set value   CH1-CH192
538C-544B	Heater overcurrent alarm selection   CH1-CH192
544C-550B	Heater break alarm (HBA) interlock release   CH1-CH192
550C-55CB	Heater overcurrent alarm interlock release   CH1-CH192
5E0C-5E1B	Set lock   CH1-CH16
5E1C-5EDB	CT type   CH1-CH192
5EDC-5F9B	CT ratio (CT number of winds)   CH1-CH192
5F9C-605B	Number of heater break alarm (HBA) delay times   CH1-CH192
605C-611B	Automatic setting factor for heater break alarm (HBA)   CH1-CH192
611C-61DB	Automatic setting factor for heater overcurrent alarm   CH1-CH192
61DC-629B	Determination current value for automatic setting   CH1-CH192
629C-635B	Automatic setting time   CH1-CH192
635C-641B	Module address assignments for CT input   CH1-CH192
641C-64DB	Module channel assignments for CT input   CH1-CH192
64DC-659B	Load factor conversion method 2   CH1-CH192
659C-65AB	CT Interval time   CH1-CH16
8000		Communication 1 protocol
8001		Communication 1 communication speed
8002		Communication 1 data bit configuration
8003		Communication 1 interval time
8004		Communication 2 protocol
8005		Communication 2 communication speed
8006		Communication 2 data bit configuration
8007		Communication 2 interval time
8008		Station number
8009		PC number (CPU No.)
800A		Register type
800B		Register start number (High-order 4-bit)
800C		Register start number (Low-order 16 bit)
800D		System data address bias
800E		COM module link recognition time
800F		PLC scanning time
8010		PLC communication start time
8011		Method for setting the number of connected modules
8012		Slave mapping method
8013		Number of connected modules (Z-TIO module)
8014		Number of connected modules (Z-DIO module)
8015		Number of connected modules (Z-CT module)
801A		Number of valid groups
801B		Control RUN/STOP holding setting (Each unit)
[SigDataEnd]