﻿Name=PLC1
SRX
MaxSigCnt=141
DataFormat=Hex

[SigData]
00	M1(ch1)	Measured-value (PV)
01	M1(ch2)	Measured-value (PV)
02	AJ(ch1)	Overall event status
02.00	AJ(ch1)	Burnout
02.01	AJ(ch1)	Event 1
02.02	AJ(ch1)	Event 2
02.03	AJ(ch1)	Heater break alarm
02.04	AJ(ch1)	Control loop break alarm
03	AJ(ch2)	Overall event status
03.00	AJ(ch2)	Burnout
03.01	AJ(ch2)	Event 1
03.02	AJ(ch2)	Event 2
03.03	AJ(ch2)	Heater break alarm
03.04	AJ(ch2)	Control loop break alarm
04	B1(ch1)	Burnout state
05	B1(ch2)	Burnout state
06	AA(ch1)	Event 1 state
07	AA(ch2)	Event 1 state
08	AB(ch1)	Event 2 state
09	AB(ch2)	Event 2 state
0A	AC(ch1)	Heater break alarm (HBA) state
0B	AC(ch2)	Heater break alarm (HBA) state
0C	AP(ch1)	Control loop break alarm (LBA) state
0D	AP(ch2)	Control loop break alarm (LBA) state
0E	O1(ch1)	Manipulated output value
0F	O1(ch2)	Manipulated output value
10	M3(ch1)	CT input measured value
11	M3(ch2)	CT input measured value
12	MS(ch1)	Set-value monitoring
13	MS(ch2)	Set-value monitoring
14	ER	Error code 
14.00	ER	Memory backup error
14.02	ER	Internal communication error
14.03	ER	Adjustment data error
14.04	ER	Input A/D error
14.05	ER	CT input A/D error
14.06	ER	Temperature compensation A/D error
15	S1(ch1)	Set value (SV)
16	S1(ch2)	Set value (SV)
17	P1(ch1)	Proportional band
18	P1(ch2)	Proportional band
19	I1(ch1)	Integral time
1A	I1(ch2)	Integral time
1B	D1(ch1)	Derivative time
1C	D1(ch2)	Derivative time
1D	CA(ch1)	Control response designation parameter
1E	CA(ch2)	Control response designation parameter
1F	PB(ch1)	PV bias
20	PB(ch2)	PV bias
21	A1(ch1)	Event 1 setting value
22	A1(ch2)	Event 1 setting value
23	A2(ch1)	Event 2 setting value
24	A2(ch2)	Event 2 setting value
25	EI(ch1)	Operation mode
26	EI(ch2)	Operation mode
27	G1(ch1)	PID/AT transfer
28	G1(ch2)	PID/AT transfer
29	J1(ch1)	Auto/Manual transfer
2A	J1(ch2)	Auto/Manual transfer
2B	ON(ch1)	Manual output value
2C	ON(ch2)	Manual output value
2D	OH(ch1)	Output limiter (high)
2E	OH(ch2)	Output limiter (high)
2F	OL(ch1)	Output limiter (low)
30	OL(ch2)	Output limiter (low)
31	T0(ch1)	Proportioning cycle
32	T0(ch2)	Proportioning cycle
33	F1(ch1)	digital filter
34	F1(ch2)	digital filter
35	A3(ch1)	Heater break alarm (HBA) set value
36	A3(ch2)	Heater break alarm (HBA) set value
37	DH(ch1)	Number of heater break alarm (HBA) delay times
38	DH(ch2)	Number of heater break alarm (HBA) delay times
39	XN(ch1)	Hot/Cold start selection
3A	XN(ch2)	Hot/Cold start selection
3B	SX(ch1)	Start determination point
3C	SX(ch2)	Start determination point
3D	SR	Control RUN/STOP transfer 
3E	AV(ch1)	Input error determination point (high)
3F	AV(ch2)	Input error determination point (high)
40	AW(ch1)	Input error determination point (low)
41	AW(ch2)	Input error determination point (low)
42	WH(ch1)	Action (high) at input error
43	WH(ch2)	Action (high) at input error
44	WL(ch1)	Action (low) at input error
45	WL(ch2)	Action (low) at input error
46	OE(ch1)	Manipulated output value at input error
47	OE(ch2)	Manipulated output value at input error
48	GH(ch1)	AT differential gap time
49	GH(ch2)	AT differential gap time
4A	GB(ch1)	AT bias
4B	GB(ch2)	AT bias
4C	C1	Remote/Local transfer 
4D	XH	Event LED mode set
4E	E1(ch1)	Digital input setting 1 (RESET)
4F	E1(ch2)	Digital input setting 1 (RESET)
50	E2(ch1)	Digital input setting 2 (RUN)
51	E2(ch2)	Digital input setting 2 (RUN)
52	E3(ch1)	Digital input setting 3 (FIX)
53	E3(ch2)	Digital input setting 3 (FIX)
54	E4(ch1)	Digital input setting 4 (MAN)
55	E4(ch2)	Digital input setting 4 (MAN)
56	E5(ch1)	Digital input setting 5 (HOLD)
57	E5(ch2)	Digital input setting 5 (HOLD)
58	E6(ch1)	Digital input setting 6 (STEP)
59	E6(ch2)	Digital input setting 6 (STEP)
5A	E7(ch1)	Digital input setting 7 (Program pattern selection)
5B	E7(ch2)	Digital input setting 7 (Program pattern selection)
5C	E8(ch1)	Digital input setting 8 (AT/PID)
5D	E8(ch2)	Digital input setting 8 (AT/PID)
5E	HP(ch1)	Control loop break alarm (LBA) usage selection
5F	HP(ch2)	Control loop break alarm (LBA) usage selection
60	C6(ch1)	Control loop break alarm (LBA) time
61	C6(ch2)	Control loop break alarm (LBA) time
62	V2(ch1)	Control loop break alarm (LBA) deadband
63	V2(ch2)	Control loop break alarm (LBA) deadband
64	PK(ch1)	Integral/Derivative time decimal point position
65	PK(ch2)	Integral/Derivative time decimal point position
66	IN	Initial set mode
67	XI(ch1)	Input range number
68	XI(ch2)	Input range number
69	XV(ch1)	Input scale high
6A	XV(ch2)	Input scale high
6B	XW(ch1)	Input scale low
6C	XW(ch2)	Input scale low
6D	XU(ch1)	Input range decimal point position
6E	XU(ch2)	Input range decimal point position
6F	PU(ch1)	Temperature unit selection
70	PU(ch2)	Temperature unit selection
71	XE(ch1)	Control type
72	XE(ch2)	Control type
73	IV(ch1)	ON/OFF action differential gap (upper)
74	IV(ch2)	ON/OFF action differential gap (upper)
75	IW(ch1)	ON/OFF action differential gap (lower)
76	IW(ch2)	ON/OFF action differential gap (lower)
77	HA(ch1)	Event 1 differential gap
78	HA(ch2)	Event 1 differential gap
79	HB(ch1)	Event 2 differential gap
7A	HB(ch2)	Event 2 differential gap
7B	XA(ch1)	Event 1 type
7C	XA(ch2)	Event 1 type
7D	XB(ch1)	Event 2 type
7E	XB(ch2)	Event 2 type
7F	WA(ch1)	Event 1 action
80	WA(ch2)	Event 1 action
81	WB(ch1)	Event 2 action
82	WB(ch2)	Event 2 action
83	DF(ch1)	Event delay frequency
84	DF(ch2)	Event delay frequency
85	ZX	Transmission transfer time setting
86	XP(ch1)	Segment time unit setting
87	XP(ch2)	Segment time unit setting
88	X2	Transfer mode hold setting
89	PH(ch1)	Change rate limiter(up) of output
8A	PH(ch2)	Change rate limiter(up) of output
8B	PL(ch1)	Change rate limiter(down) of output
8C	PL(ch2)	Change rate limiter(down) of output
[SigDataEnd]