﻿Name=PLC1
SRZ
MaxSigCnt=208
DataFormat=Hex

[SigData]
00	VR	ROM version (1-4 character)
01	VR	ROM version (5-8 character)
02	M1	Measured value (PV)
03	AJ	Comprehensive event state
04	L0	Operation mode state monitor
05	ER	Error code
05.00	ER	Adjustment data error (Error code)
05.01	ER	Data back-up error (Error code)
05.02	ER	A/D conversion error (Error code)
05.05	ER	Logic output data error (Error code)
06	O1	Manipulated output value (MV) monitor [heat-side]
07	O2	Manipulated output value (MV) monitor [cool-side]
08	M3	Current transformer (CT) input value monitor
09	MS	Set value (SV) monitor
0A	S2	Remote setting (RS) input value monitor
0B	B1	Burnout state monitor
0C	AA	Event 1 state monitor
0D	AB	Event 2 state monitor
0E	AC	Event 3 state monitor
0F	AD	Event 4 state monitor
10	AE	Heater break alarm (HBA) state monitor
11	Q1	Output state monitor
12	TR	Memory area soak time monitor
13	UT	Integrated operating time monitor
14	Hp	Holding peak value ambient temperature monitor
15	EM	Backup memory state monitor
16	ED	Logic output monitor 1
17	EE	Logic output monitor 2
18	G1	PID/AT transfer
19	J1	Auto/Manual transfer
1A	C1	Remote/Local transfer
1B	SR	RUN/STOP transfer
1C	ZA	Memory area transfer
1D	AR	Interlock release
1E	A1	Event 1 set value (EV1)
1F	A2	Event 2 set value (EV2)
20	A3	Event 3 set value (EV3)
21	A4	Event 4 set value (EV4)
22	A5	Control loop break alarm (LBA) time
23	N1	LBA deadband
24	S1	Set value (SV)
25	P1	Proportional band [heat-side]
26	I1	Integral time [heat-side]
27	D1	Derivative time [heat-side]
28	CA	Control response parameter
29	P2	Proportional band [cool-side]
2A	I2	Integral time [cool-side]
2B	D2	Derivative time [cool-side]
2C	V1	Overlap/Deadband
2D	MR	Manual reset
2E	HH	Setting change rate limiter (up)
2F	HL	Setting change rate limiter (down)
30	TM	Area soak time
31	LP	Link area number
32	A7	Heater break alarm (HBA) set value
33	NE	Heater break determination point
34	NF	Heater melting determination point
35	PB	PV bias
36	F1	PV digital filter
37	PR	PV ratio
38	DP	PV low input cut-off
39	RB	RS bias
3A	F2	RS digital filter
3B	RR	RS ratio
3C	DV	Output distribution selection
3D	DW	Output distribution bias
3E	DQ	Output distribution ratio
3F	T0	Proportional cycle time
40	VI	Minimum ON/OFF time of proportioning cycle
41	ON	Manual manipulated output value
42	RV	Area soak time stop function
43	NG	EDS mode (for disturbance 1)
44	NX	EDS mode 2 (for disturbance 2)
45	NI	EDS value 1 (for disturbance 1)
46	NJ	EDS value 1 (for disturbance 2)
47	NK	EDS value 2 (for disturbance 1)
48	NM	EDS value 2 (for disturbance 2)
49	NN	EDS transfer time (for disturbance 1)
4A	NO	EDS transfer time (for disturbance 2)
4B	NQ	EDS action time (for disturbance 1)
4C	NL	EDS action time (for disturbance 2)
4D	NR	EDS action wait time (for disturbance 1)
4E	NY	EDS action wait time (for disturbance 2)
4F	NT	EDS value learning times
50	NU	EDS start signal
51	EI	Operation mode
52	ST	Startup tuning (ST)
53	Y8	Automatic temperature rise learning
54	EF	Communication switch for logic
55	XI	Input type
56	PU	Display unit
57	XU	Decimal point position
58	XV	Input scale high
59	XW	Input scale low
5A	AV	Input error determination point (high)
5B	AW	Input error determination point (low)
5C	BS	Burnout direction
5D	XH	Square root extraction
5E	E0	Output assignment (Logic output selection function)
5F	NA	Energized/De-energized (Logic output selection function)
60	XA	Event 1 type
61	FA	Event 1 channel setting
62	WA	Event 1 hold action
63	LF	Event 1 interlock
64	HA	Event 1 differential gap
65	TD	Event 1 delay timer
66	OA	Force ON of Event 1 action
67	XB	Event 2 type
68	FB	Event 2 channel setting
69	WB	Event 2 hold action
6A	LG	Event 2 interlock
6B	HB	Event 2 differential gap
6C	TG	Event 2 delay timer
6D	OB	Force ON of Event 2 action
6E	XC	Event 3 type
6F	FC	Event 3 channel setting
70	WC	Event 3 hold action
71	LH	Event 3 interlock
72	HC	Event 3 differential gap
73	TE	Event 3 delay timer
74	OC	Force ON of Event 3 action
75	XD	Event 4 type
76	FD	Event 4 channel setting
77	WD	Event 4 hold action
78	LI	Event 4 interlock
79	HD	Event 4 differential gap
7A	TF	Event 4 delay timer
7B	OD	Force ON of Event 4 action
7C	XS	CT ratio
7D	ZF	CT assignment
7E	ND	Heater break alarm (HBA) type
7F	DH	Number of heater break alarm (HBA) delay times
80	XN	Hot/Cold start
81	SX	Start determination point
82	XL	SV tracking
83	OT	MV transfer function [Action taken when changed to Manual mode from Auto mode]
84	XE	Control action
85	PK	Integral/derivative time decimal point position
86	KA	Derivative action
87	KB	Undershoot suppression factor
88	DG	Derivative gain
89	IV	ON/OFF action differential gap (upper)
8A	IW	ON/OFF action differential gap (lower)
8B	WH	Action (high) at input error
8C	WL	Action (low) at input error
8D	OE	Manipulated output value at input error
8E	OF	Manipulated output value at STOP mode [heat-side]
8F	OG	Manipulated output value at STOP mode [cool-side]
90	PH	Output change rate limiter (up) [heat-side]
91	PL	Output change rate limiter (down) [heat-side]
92	OH	Output limiter (high) [heat-side]
93	OL	Output limiter (low) [heat-side]
94	PX	Output change rate limiter (up) [cool-side]
95	PY	Output change rate limiter (down) [cool-side]
96	OX	Output limiter (high) [cool-side]
97	OY	Output limiter (low) [cool-side]
98	GB	AT bias
99	G3	AT cycles
9A	OP	Output value with AT turned on
9B	OQ	Output value with AT turned off
9C	GH	AT differential gap time
9D	KC	Proportional band adjusting factor [heat-side]
9E	KD	Integral time adjusting factor [heat-side]
9F	KE	Derivative time adjusting factor [heat-side]
A0	KF	Proportional band adjusting factor [cool-side]
A1	KG	Integral time adjusting factor [cool-side]
A2	KH	Derivative time adjusting factor [cool-side]
A3	P6	Proportional band limiter (high) [heat-side]
A4	P7	Proportional band limiter (low) [heat-side]
A5	I6	Integral time limiter (high) [heat-side]
A6	I7	Integral time limiter (low) [heat-side]
A7	D6	Derivative time limiter (high) [heat-side]
A8	D7	Derivative time limiter (low) [heat-side]
A9	P8	Proportional band limiter (high) [cool-side]
AA	P9	Proportional band limiter (low) [cool-side]
AB	I8	Integral time limiter (high) [cool-side]
AC	I9	Integral time limiter (low) [cool-side]
AD	D8	Derivative time limiter (high) [cool-side]
AE	D9	Derivative time limiter (low) [cool-side]
AF	V2	Open/Close output neutral zone
B0	SY	Action at feedback resistance (FBR) input error
B1	FV	Feedback adjustment
B2	TN	Control motor time
B3	OI	Integrated output limiter
B4	VS	Valve action at STOP
B5	KI	ST proportional band adjusting factor
B6	KJ	ST integral time adjusting factor
B7	KK	ST derivative time adjusting factor
B8	SU	ST start condition
B9	Y7	Automatic temperature rise group
BA	RT	Automatic temperature rise dead time
BB	R2	Automatic temperature rise gradient data
BC	NS	EDS transfer time decimal point position
BD	NV	Output average processing time for EDS
BE	NW	Responsive action trigger point for EDS
BF	HU	Setting change rate limiter unit time
C0	RU	Soak time unit
C1	SH	Setting limiter (high)
C2	SL	Setting limiter (low)
C3	TS	PV transfer function
C4	EA	Operation mode assignment 1 (Logic output selection function) Logic output 1 to 4
C5	EB	Operation mode assignment 2 (Logic output selection function) Logic output 5 to 8
C6	KM	SV select function
C7	MC	Remote SV function master channel module address
C8	MN	Remote SV function master channel selection
C9	DY	Output distribution master channel module address
CA	DZ	Output distribution master channel selection
CB	RL	Address of interacting modules
CC	RM	Channel selection of interacting modules
CD	RN	Selection switch of interacting modules
CE	X1	Control RUN/STOP holding setting
CF	ZX	Interval time
[SigDataEnd]