﻿﻿Name=Inverter
Varispeed L7
MaxSigCnt=0
DataFormat=Hex

[SigData]
0001	Frequency reference
0002	Frequency reference (Set units using constant o1-03)
0007	Analog output 1 setting (-11 V/-1540 to 11 V/1540)
0008	Analog output 2 setting (-11 V/-1540 to 11 V/1540)
0009	Multi-function contact output setting
000F	Reference selection settings
0020	Inverter status
0021	Error details
0022	Data link status
0023	Frequency reference (U1-01)
0024	Output frequency (U1-02)
0025	Output voltage reference (U1-06)
0026	Output current (U1-03) (Unit: 1/0.1A)
0027	Output power (U1-08)
0028	Torque reference (U1-09)
002B	Sequence input status
002C	Inverter status
002D	Multi-function contact output status
0031	Main circuit DC voltage
0032	Torque monitor (Unit: 1/0.1%)
0033	Output power (U1-08)
003B	CPU software number
003C	Flash software number
003D	Communications error details
003E	kVA setting
003F	Control method
0900	Write constant data to EEPROM
0910	Constant data is not written to EEPROM, but refreshed in RAM only.
0100	A1-00	Language selection for Digital Operator display
0101	A1-01	Constant access level
0102	A1-02	Control method selection
0103	A1-03	Initialize
0104	A1-04	Password
0105	A1-05	Password setting
0106	A2-01	User specified parameters
0107	A2-02	User specified parameters
0108	A2-03	User specified parameters
0109	A2-04	User specified parameters
010A	A2-05	User specified parameters
010B	A2-06	User specified parameters
010C	A2-07	User specified parameters
010D	A2-08	User specified parameters
010E	A2-09	User specified parameters
010F	A2-10	User specified parameters
0110	A2-11	User specified parameters
0111	A2-12	User specified parameters
0112	A2-13	User specified parameters
0113	A2-14	User specified parameters
0114	A2-15	User specified parameters
0115	A2-16	User specified parameters
0116	A2-17	User specified parameters
0117	A2-18	User specified parameters
0118	A2-19	User specified parameters
0119	A2-20	User specified parameters
011A	A2-21	User specified parameters
011B	A2-22	User specified parameters
011C	A2-23	User specified parameters
011D	A2-24	User specified parameters
011E	A2-25	User specified parameters
011F	A2-26	User specified parameters
0120	A2-27	User specified parameters
0121	A2-28	User specified parameters
0122	A2-29	User specified parameters
0123	A2-30	User specified parameters
0124	A2-31	User specified parameters
0125	A2-32	User specified parameters
0180	b1-01	Reference rource selection
0181	b1-02	Run Command source selection
0182	b1-03	Stopping method selection
0185	b1-06	Control input scan
0186	b1-07	Operation selection after switching to remote mode
0187	b1-08	Run Command selection in programming modes
0190	b2-08	Magnetic flux compensation volume
01A3	b4-01	Timer function ON-delay time
01A4	b4-02	Timer function OFF-delay time
01B6	b6-01	Dwell frequency at start
01B7	b6-02	Dwell time at start
01B8	b6-03	Dwell frequency at stop
01B9	b6-04	Dwell time at stop
01CA	b7-01	Droop control gain
01CB	b7-02	Droop control delay time
01CC	b8-01	Energy-saving mode selection
01F8	b8-16	Energy savings control parameter Ki
01F9	b8-17	Energy savings control parameter Kt
0200	C1-01	Acceleration time 1
0201	C1-02	Deceleration time 1
0202	C1-03	Acceleration time 2
0203	C1-04	Deceleration time 2
0204	C1-05	Acceleration time 3
0205	C1-06	Deceleration time 3
0206	C1-07	Acceleration time 4
0207	C1-08	Deceleration time 4
0208	C1-09	Fast stop time
0209	C1-10	Accel/decel time setting unit
020A	C1-11	Accel/decel time switching frequency
020B	C2-01	S-curve characteristic time at acceleration start
020C	C2-02	S-curve characteristic time at acceleration end
020D	C2-03	S-curve characteristic time at deceleration start
020E	C2-04	S-curve characteristic time at deceleration end
0232	C2-05	S character characteristic time below leveling speed
020F	C3-01	Slip compensation gain
0210	C3-02	Slip compensation primary delay time
0211	C3-03	Slip compensation limit
0212	C3-04	Slip compensation selection during regeneration
0213	C3-05	Output voltage limit operation selection
0215	C4-01	Torque compensation gain
0216	C4-02	Torque compensation delay time parameter
0217	C4-03	Starting torque compensation (FWD)
0218	C4-04	Starting torque compensation (REV)
0219	C4-05	Starting torque compensation time parameter
021A	C4-06	Torque compensation primary delay time 2
021B	C5-01	ASR proportional (P) gain 1
021C	C5-02	ASR integral (I) time 1
021D	C5-03	ASR proportional (P) gain 2
021E	C5-04	ASR integral (I) time 2
0220	C5-06	ASR primary delay time
0221	C5-07	ASR switching frequency
0222	C5-08	ASR integral (I) limit
022E	C5-09	ASR proportional (P) gain 3
0231	C5-10	ASR integral (I) time 3
0238	C5-15	ASR gain for encoder offset tuning
0224	C6-02	Carrier frequency selection
0225	C6-03	Carrier frequency upper limit
022B	C6-09	Carrier during rotational autotuning
022C	C6-10	Carrier during stationary autotuning
022D	C6-11	Carrier frequency selection 2
0280	d1-01	Frequency reference 1
0281	d1-02	Frequency reference 2
0282	d1-03	Frequency reference 3
0283	d1-04	Frequency reference 4
0284	d1-05	Frequency reference 5
0285	d1-06	Frequency reference 6
0286	d1-07	Frequency reference 7
0287	d1-08	Frequency reference 8
0288	d1-09	Nominal speed reference
028B	d1-10	Intermediate speed 1 reference
028C	d1-11	Intermediate speed 2 reference
028D	d1-12	Intermediate speed 3 reference
028E	d1-13	Releveling speed reference
028F	d1-14	Inspection speed reference
0292	d1-17	Leveling speed reference
02A7	d1-18	Speed priority selection
02A2	d6-03	Field forcing function selection
02A5	d6-06	Field forcing limit value
0300	E1-01	Input voltage setting
0302	E1-03	V/f pattern selection
0303	E1-04	Max. output frequency (FMAX)
0304	E1-05	Max. output voltage (VMAX)
0305	E1-06	Base frequency (FA)
0306	E1-07	Mid. output frequency (FB)
0307	E1-08	Mid. Output frequency voltage (VB)
0308	E1-09	Min. output frequency (FMIN)
0309	E1-10	Min. output frequency voltage (VMIN)
030C	E1-13	Base voltage (VBASE)
030E	E2-01	Motor rated current
030F	E2-02	Motor rated slip
0310	E2-03	Motor noload current
0311	E2-04	Number of motor poles
0312	E2-05	Motor line-to-line resistance
0313	E2-06	Motor leak inductance
0314	E2-07	Motor iron saturation coefficient 1
0315	E2-08	Motor iron saturation coefficient 2
0316	E2-09	Motor mechanical loss
0317	E2-10	Motor iron loss for torque compensation
0318	E2-11	Motor rated output power
0328	E2-12	Motor iron saturation coefficient 3
032A	E5-02	Motor rated power
032B	E5-03	Motor rated current
032C	E5-04	Number of motor poles
032D	E5-05	Motor line-to-line resistance
032E	E5-06	d-axis inductance
032F	E5-07	q-axis inductance
0331	E5-09	Motor voltage parameter
0333	E5-11	PG home position offset
0380	F1-01	PG constant
0381	F1-02	Operation selection at PG open circuit (PGO)
0382	F1-03	Operation selection at overspeed (OS)
0383	F1-04	Operation selection at deviation
0384	F1-05	PG rotation
0385	F1-06	PG division rate (PG pulse monitor)
0387	F1-08	Overspeed detection level
0388	F1-09	Overspeed detection delay time
0389	F1-10	Excessive speed deviation detection level
038A	F1-11	Excessive speed deviation detection delay time
038D	F1-14	PG open-circuit detection time
03AD	F1-18	DV3 fault detection selection
03AE	F1-19	DV4 fault detection selection
03B0	F1-21	Absolute encoder resolution
03B1	F1-22	Magnet position offset
03B4	F1-25	Encoder copy selection
03B5	F1-26	Encoder copy write permission selection
0391	F4-01	Channel 1 monitor selection
0392	F4-02	Channel 1 gain
0393	F4-03	Channel 2 monitor selection
0394	F4-04	Channel 2 gain
0395	F4-05	Channel 1 output monitor bias
0396	F4-06	Channel 2 output monitor bias
0397	F4-07	Analog output signal level for channel 1
0398	F4-08	Analog output signal level for channel 2
0399	F5-01	Channel 1 output selection
039A	F5-02	Channel 2 output selection
039B	F5-03	Channel 3 output selection
039C	F5-04	Channel 4 output selection
039D	F5-05	Channel 5 output selection
039E	F5-06	Channel 6 output selection
039F	F5-07	Channel 7 output selection
03A0	F5-08	Channel 8 output selection
03A1	F5-09	DO-08 output mode selection
03A2	F6-01	Operation selection after communications error
03A3	F6-02	Input level of external fault from communications option card
03A4	F6-03	Stopping method for external fault from communications option card
03A5	F6-04	Trace sampling from communications option card
03A6	F6-05	Current monitor unit selection
03A7	F6-06	Torque reference/torque limit selection from communications option card
0400	H1-01	Terminal S3 function selection
0401	H1-02	Terminal S4 function selection
0402	H1-03	Terminal S5 function selection
0403	H1-04	Terminal S6 function selection
0404	H1-05	Terminal S7 function selection
040B	H2-01	Terminal M1-M2 function selection
040C	H2-02	Terminal M3-M4 function selection
040D	H2-03	Terminal M5-M6 function selection
0410	H3-01	AI-14B Channel 1 signal level selection
0411	H3-02	AI-14B Channel 1 gain
0412	H3-03	AI-14B Channel 1 bias
0413	H3-04	AI-14B Channel 3 signal level selection
0414	H3-05	AI-14B Channel 3 function selection
0415	H3-06	AI-14B Channel 3 gain
0416	H3-07	AI-14B Channel 3 bias
0417	H3-08	AI-14B Channel 2 signal level selection
0418	H3-09	AI-14B Channel 2 function selection
0419	H3-10	AI-14B Channel 2 gain
041A	H3-11	AI-14B Channel 2 bias
041B	H3-12	Analog input filter time parameter
0434	H3-15	Terminal A1 function selection
0435	H3-16	Terminal A1 input gain
0436	H3-17	Terminal A1 input bias
0425	H5-01	Slave address
0426	H5-02	Communication speed selection
0427	H5-03	Communication parity selection
0428	H5-04	Stopping method after communication error
0429	H5-05	Communication error detection selection
042A	H5-06	Send wait time
042B	H5-07	RTS control ON/OFF
0480	L1-01	Motor protection selection
0481	L1-02	Motor protection time constant
0489	L2-05	Undervoltage detection level
04CB	L2-11	Battery Voltage
048F	L3-01	Stall prevention selection during accel
0490	L3-02	Stall prevention level during accel
0491	L3-03	Stall prevention limit during accel
0492	L3-04	Stall prevention selection during decel
0493	L3-05	Stall prevention selection during running
0494	L3-06	Stall prevention level during running
0499	L4-01	Speed agreement detection level
049A	L4-02	Speed agreement detection width
049B	L4-03	Speed agreement detection level (+/-)
049C	L4-04	Speed agreement detection width (+/-)
049D	L4-05	Operation when frequency reference is missing
04C2	L4-06	Frequency reference when frequency reference is lost
049E	L5-01	Number of auto restart attempts
049F	L5-02	Auto restart operation selection
04A0	L5-03	Abnormal retry interval time
04CC	L5-05	Under voltage fault restart selection
04A1	L6-01	Torque detection selection 1
04A2	L6-02	Torque detection level 1
04A3	L6-03	Torque detection time 1
04A4	L6-04	Torque detection selection 2
04A5	L6-05	Torque detection level 2
04A6	L6-06	Torque detection time 2
04A7	L7-01	Forward drive torque limit
04A8	L7-02	Reverse drive torque limit
04A9	L7-03	Forward regenerative torque limit
04AA	L7-04	Reverse regenerative torque limit
04AC	L7-06	Torque limit time parameter
04C9	L7-07	Torque Limit Operation during accel/decel
04AE	L8-02	Overheat pre-alarm level
04AF	L8-03	Operation selection after overheat prealarm
04B1	L8-05	Input openphase protection selection
04B3	L8-07	Output open-phase protection selection
04B5	L8-09	Ground fault detection selection
04B6	L8-10	Cooling fan control selection
04B7	L8-11	Cooling fan control delay time
04B8	L8-12	Ambient temperature
04BE	L8-18	Soft CLA selection
04C0	L8-20	Output phase loss detection time
04E2	L8-32	OH1 detection during cooling fan failure
0584	N2-01	Speed feedback detection control (AFR) gain
0585	N2-02	Speed feedback detection control (AFR) time constant
0586	N2-03	Speed feedback detection control (AFR) time constant 2
05B0	N5-01	Feed forward control selection
05B1	N5-02	Motor acceleration time
05B2	N5-03	Feed forward proportional gain
0540	N8-01	Initial magnetic polarity estimation current
0562	N8-35	Magnet position detection method
0563	N8-36	Magnet position detection method 2 frequency
0564	N8-37	Magnet position detection method 2 current level
0566	N8-39	Low pass filter cut-off frequency for magnet position detection method 2
056D	N8-46	Inductance measurement current level
064D	N9-60	A/D conversion start delay time
065B	N9-74	Leakage current reduction selection
0500	o1-01	Monitor selection
0501	o1-02	Monitor selection after power up
0502	o1-03	Frequency units of reference setting and monitor
0503	o1-04	Setting unit for frequency constants related to V/f characteristics
0504	o1-05	LCD Display contrast adjustment
0505	o2-01	LOCAL/REMOTE key enable/disable
0506	o2-02	STOP key during control circuit terminal operation
0507	o2-03	Parameter initial value
0508	o2-04	kVA selection
0509	o2-05	Frequency reference setting method selection
050A	o2-06	Operation selection when digital operator is disconnected
050B	o2-07	Cumulative operation time setting
050C	o2-08	Cumulative operation time selection
050D	o2-09	Initialization mode
050E	o2-10	Fan operation time setting
0510	o2-12	Fault trace initialize
0513	o2-15	Number of Travels counter initialize
0515	o3-01	Copy function selection
0516	o3-02	Read permitted selection
0680	S1-01	Zero speed level at stop
0681	S1-02	DC injection braking current at start
0682	S1-03	DC injection braking current at stop
0683	S1-04	DC injection braking/zerospeed time at start
0684	S1-05	DC injection braking/zerospeed time at stop
0685	S1-06	Brake release delay time
0686	S1-07	Brake close delay time
068D	S1-14	SE2 detection delay time
068E	S1-15	SE3 detection delay time
068F	S1-16	Run delay time
0690	S1-17	DC injection current gain at regenerative operation
0691	S1-18	DC injection current gain at motoring operation
0692	S1-19	Magnetic contactor open delay time
0693	S1-20	Zero servo gain
0694	S1-21	Zero-servo completion width
0695	S1-22	Starting torque compensation increase time
0696	S1-23	Torque compensation gain during lowering
0697	S1-24	Torque compensation bias during raising
0698	S1-25	Torque compensation bias during lowering
0699	S1-26	Torque compensation gain during lowering
069A	S1-27	Door zone speed level
069B	S1-28	SE1 selection
069E	S1-31	Torque limit time at stop
06AE	S2-01	Motor rated speed
06AF	S2-02	Slip compensation gain in motoring mode
06B0	S2-03	Slip compensation gain in regenerative mode
06B4	S2-07	Slip compensation delay time
06BC	S2-15	Slip compensation selection during regeneration
06BD	S3-01	Short floor function selection
06C4	S3-08	Output phase order
06C5	S3-09	Frequency reference loss fault detection
06C9	S3-13	Traction sheave diameter
06CA	S3-14	Roping
06CC	S3-16	Over acceleration detection level
06CD	S3-17	Over acceleration detection filter time
06CE	S3-18	Over acceleration detection selection
06D3	S3-23	Distance calculation deceleration time gain
0701	T1-01	Autotuning mode selection
0702	T1-02	Motor output power
0703	T1-03	Motor rated voltage
0704	T1-04	Motor rated current
0705	T1-05	Motor base frequency
0706	T1-06	Number of motor poles
0707	T1-07	Motor base speed
0708	T1-08	Number of PG pulses
0709	T1-09	Motor noload current
0730	T2-01	Motor output power
0731	T2-02	Motor base frequency
0732	T2-03	Motor rated voltage
0733	T2-04	Motor rated current
0734	T2-05	Number of motor poles
0735	T2-06	Motor d axis inductance
0737	T2-08	Motor voltage parameter
0738	T2-09	Number of PG pulses
072F	T2-10	Motor voltage parameter calculation selection
0040	U1-01	Frequency reference
0041	U1-02	Output frequency
0042	U1-03	Output current
0043	U1-04	Control method
0044	U1-05	Motor speed
0045	U1-06	Output voltage
0046	U1-07	DC bus voltage
0047	U1-08	Output power
0048	U1-09	Torque reference
0049	U1-10	Input terminal status
004A	U1-11	Output terminal status
004B	U1-12	Operation status
004C	U1-13	Cumulative operation time
004D	U1-14	Software No. (flash memory)
004E	U1-15	Terminal A1 or A1-14B channel 1 input voltage level
004F	U1-16	AI-14B channel 2 input voltage level
0050	U1-17	AI-14B channel 3 input voltage level
0051	U1-18	Motor secondary current (Iq)
0052	U1-19	Motor exciting current (Id)
0053	U1-20	Frequency reference after softstarter
0054	U1-21	ASR input
0055	U1-22	ASR output
0058	U1-25	DI-16H2 input status
0059	U1-26	Output voltage reference (Vq)
005A	U1-27	Output voltage reference (Vd)
005B	U1-28	Software No. (CPU)
005F	U1-32	ACR output of q axis
0060	U1-33	ACR output of d axis
0061	U1-34	OPE fault constant
0062	U1-35	Zero-servo movement pulses
0066	U1-39	MEMOBUS communications error code
0067	U1-40	Cooling fan operating time
0068	U1-41	Heatsink Temperature
006B	U1-44	ASR output without filter
006C	U1-45 	Feed forward control output
0071	U1-50	Slip compensation value
0072	U1-51	Max Current during acceleration
0073	U1-52	Max Current during deceleration
0074	U1-53	Max Current during Top speed
0075	U1-54	Max Current during leveling speed
0076	U1-55	Operation counter
0077	U1-56	AI-14B channel 1 input voltage level
0078	U1-57	Car acceleration rate
07C6	U1-74	q-axis motor current reference
07C7	U1-75	d-axis motor current reference
0080	U2-01	Current fault
0081	U2-02	Last fault
0082	U2-03	Reference frequency at fault
0083	U2-04	Output frequency at fault
0084	U2-05	Output current at fault
0085	U2-06	Motor speed at fault
0086	U2-07	Output voltage reference at fault
0087	U2-08	DC bus voltage at fault
0088	U2-09	Output power at fault
0089	U2-10	Torque reference at fault
008A	U2-11	Input terminal status at fault
008B	U2-12	Output terminal status at fault
008C	U2-13	Operation status at fault
008D	U2-14	Cumulative operation time at fault
07E0	U2-15	Soft Starter Speed Reference at Fault
07E1	U2-16	q-Axis Current at Fault
07E2	U2-17	d-Axis Current at Fault
0090	U3-01	Last fault
0091	U3-02	Second last fault
0092	U3-03	Third last fault
0093	U3-04	Fourth last fault
0094	U3-05	Cumulative operation time at fault
0095	U3-06	Accumulated time of second fault
0096	U3-07	Accumulated time of third fault
0097	U3-08	Accumulated time of fourth fault
0804	U3-09	Fifth last fault
0805	U3-10	Sixth last fault
0806	U3-11	Seventh last fault
0807	U3-12	Eighth last fault
0808	U3-13	Ninth last fault
0809	U3-14	Tenth last fault
080E	U3-15	Accumulated time of fifth fault
080F	U3-16	Accumulated time of sixth fault
0810	U3-17	Accumulated time of secenth fault
0811	U3-18	Accumulated time of eighth fault
0812	U3-19	Accumulated time of ninth fault
0813	U3-20	Accumulated time of tenth fault
0800	U3-01	Last fault
0801	U3-02	Second last fault
0802	U3-03	Third last fault
0803	U3-04	Fourth last fault
080A	U3-05	Cumulative operation time at fault
080B	U3-06	Accumulated time of second fault
080C	U3-07	Accumulated time of third fault
080D	U3-08	Accumulated time of fourth fault
[SigDataEnd]

[SigData]-B
0001.0	Forward Run/Stop Command 1: Forward run 0: Stop
0001.1	Reverse Run/Stop Command 1: Reverse run 0: Stop
0001.2	External fault 1: Error (EFO)
0001.3	Fault reset 1: Reset command
0001.4	ComNet
0001.5	ComCtrl
0001.6	Multi-function input command 3
0001.7	Multi-function input command 4
0001.8	Multi-function input command 5
0001.9	Multi-function input command 6
0001.A	Multi-function input command 7
0002	Frequency reference (Set units using constant o1-03)
0007	Analog output 1 setting (-11 V/-1540 to 11 V/1540)
0008	Analog output 2 setting (-11 V/-1540 to 11 V/1540)
0009.0	Contact output (Terminal M1-M2) 1: ON 0: OFF
0009.1	Contact output (Terminal M3-M4) 1: ON 0: OFF
0009.2	Contact output (Terminal M5-M6) 1: ON 0: OFF
0009.6	Set error contact (terminal MA-MC) output using bit 7. 1: ON 0: OFF
0009.7	Error contact (terminal MA-MC) 1: ON 0: OFF
000F.C	Broadcast data terminal S5 input 1: Enabled 0: Disabled
000F.D	Broadcast data terminal S6 input 1: Enabled 0: Disabled
000F.E	Broadcast data terminal S7 input 1: Enabled 0: Disabled
0020.0	Operation 1: Operating 0: Stopped
0020.1	Reverse operation 1: Reverse operation 0: Forward operation
0020.2	Inverter startup complete 1: Completed 2: Not completed
0020.3	Error 1: Error
0020.4	Data setting error 1: Error
0020.5	Multi-function contact output (terminal M1 - M2) 1: ON 0: OFF
0020.6	Multi-function contact output1 (terminal M3 - M4) 1: ON 0: OFF
0020.7	Multi-function contact output2 (terminal M5 - M6) 1: ON 0: OFF
0021.0	Overcurrent (OC) Ground fault (GF)
0021.1	Main circuit overvoltage (OV) 
0021.2	Inverter overload (OL2) 
0021.3	Inverter overheat (OH1, OH2) 
0021.4	Injection brake transistor resistance overheat (rr, rH) 
0021.5	Fuse blown (PUF) 
0021.6	PID feedback reference lost (FbL) 
0021.7	External fault (EF, EFO) 
0021.8	Hardware error (CPF) 
0021.9	Motor overload (OL1), overtorque 1 (OL3) detected, or overtorque 2 (OL4) detected 
0021.A	PG broken wire detected (PGO), Overspeed (OS), Speed deviation (DEV) 
0021.B	Main circuit undervoltage (UV) detected 
0021.C	Main circuit undervoltage (UV1), control power supply error (UV2), inrush prevention circuit error (UV3), power loss
0021.D	Main Circuit Voltage Fault (PF), Output Open-phase (LF) 
0021.E	MEMOBUS communications error (CE)
0021.F	Operator disconnected (OPR) 
0022.0	Writing data
0022.3	Upper and lower limit errors
0022.4	Data integrity error
0023	Frequency reference (U1-01)
0024	Output frequency (U1-02)
0025	Output voltage reference (U1-06)
0026	Output current (U1-03) (Unit: 1/0.1A)
0027	Output power (U1-08)
0028	Torque reference (U1-09)
002B.0	Multi-function contact input terminal S1 1: ON, 0: OFF
002B.1	Multi-function contact input terminal S2 1: ON, 0: OFF
002B.2	Multi-function contact input terminal S3 1: ON, 0: OFF
002B.3	Multi-function contact input terminal S4 1: ON, 0: OFF
002B.4	Multi-function contact input terminal S5 1: ON, 0: OFF
002B.5	Multi-function contact input terminal S6 1: ON, 0: OFF
002B.6	Multi-function contact input terminal S7 1: ON, 0: OFF
002C.0	Operation 1: Operating
002C.1	Zero-speed 1: Zero-speed
002C.2	Frequency matching 1: Matched
002C.3	User-defined speed matching 1: Matched
002C.4	Frequency detection 1 1: Output frequency ≤ L4-01
002C.5	Frequency detection 2 1: Output frequency ≥ L4-01
002C.6	Inverter startup completed 1: Startup completed
002C.7	Low voltage detection 1: Detected
002C.8	Baseblock 1: Inverter output baseblock
002C.9	Speed (frequency) reference mode 1: Not communications 0: Communications
002C.A	Run Command mode 1: Not communications 0: Communications
002C.B	Overtorque detection 1: Detected
002C.C	Speed (frequency) reference lost 1: Lost
002C.D	Retrying error 1: Retrying
002C.E	Error (including MEMOBUS communications time-out) 1:Error occurred
002C.F	MEMOBUS communications time-out 1: Timed out
002D.0	Multi-function contact output (terminal M1-M2) 1: ON 0: OFF
002D.1	Multi-function contact output1 (terminal M3-M4) 1: ON 0: OFF
002D.2	Multi-function contact output2 (terminal M5-M6) 1: ON 0: OFF
0031	Main circuit DC voltage
0032	Torque monitor (Unit: 1/0.1%)
0033	Output power (U1-08)
003B	CPU software number
003C	Flash software number
003D.0	CRC error
003D.1	Invalid data length
003D.3	Parity error
003D.4	Overrun error
003D.5	Framing error
003D.6	Time-out
003E	kVA setting
003F	Control method
0900	Write constant data to EEPROM
0910	Constant data is not written to EEPROM, but refreshed in RAM only.
0100	A1-00	Language selection for Digital Operator display
0101	A1-01	Constant access level
0102	A1-02	Control method selection
0103	A1-03	Initialize
0104	A1-04	Password
0105	A1-05	Password setting
0106	A2-01	User specified parameters
0107	A2-02	User specified parameters
0108	A2-03	User specified parameters
0109	A2-04	User specified parameters
010A	A2-05	User specified parameters
010B	A2-06	User specified parameters
010C	A2-07	User specified parameters
010D	A2-08	User specified parameters
010E	A2-09	User specified parameters
010F	A2-10	User specified parameters
0110	A2-11	User specified parameters
0111	A2-12	User specified parameters
0112	A2-13	User specified parameters
0113	A2-14	User specified parameters
0114	A2-15	User specified parameters
0115	A2-16	User specified parameters
0116	A2-17	User specified parameters
0117	A2-18	User specified parameters
0118	A2-19	User specified parameters
0119	A2-20	User specified parameters
011A	A2-21	User specified parameters
011B	A2-22	User specified parameters
011C	A2-23	User specified parameters
011D	A2-24	User specified parameters
011E	A2-25	User specified parameters
011F	A2-26	User specified parameters
0120	A2-27	User specified parameters
0121	A2-28	User specified parameters
0122	A2-29	User specified parameters
0123	A2-30	User specified parameters
0124	A2-31	User specified parameters
0125	A2-32	User specified parameters
0180	b1-01	Reference rource selection
0181	b1-02	Run Command source selection
0182	b1-03	Stopping method selection
0185	b1-06	Control input scan
0186	b1-07	Operation selection after switching to remote mode
0187	b1-08	Run Command selection in programming modes
0190	b2-08	Magnetic flux compensation volume
01A3	b4-01	Timer function ON-delay time
01A4	b4-02	Timer function OFF-delay time
01B6	b6-01	Dwell frequency at start
01B7	b6-02	Dwell time at start
01B8	b6-03	Dwell frequency at stop
01B9	b6-04	Dwell time at stop
01CA	b7-01	Droop control gain
01CB	b7-02	Droop control delay time
01CC	b8-01	Energy-saving mode selection
01F8	b8-16	Energy savings control parameter Ki
01F9	b8-17	Energy savings control parameter Kt
0200	C1-01	Acceleration time 1
0201	C1-02	Deceleration time 1
0202	C1-03	Acceleration time 2
0203	C1-04	Deceleration time 2
0204	C1-05	Acceleration time 3
0205	C1-06	Deceleration time 3
0206	C1-07	Acceleration time 4
0207	C1-08	Deceleration time 4
0208	C1-09	Fast stop time
0209	C1-10	Accel/decel time setting unit
020A	C1-11	Accel/decel time switching frequency
020B	C2-01	S-curve characteristic time at acceleration start
020C	C2-02	S-curve characteristic time at acceleration end
020D	C2-03	S-curve characteristic time at deceleration start
020E	C2-04	S-curve characteristic time at deceleration end
0232	C2-05	S character characteristic time below leveling speed
020F	C3-01	Slip compensation gain
0210	C3-02	Slip compensation primary delay time
0211	C3-03	Slip compensation limit
0212	C3-04	Slip compensation selection during regeneration
0213	C3-05	Output voltage limit operation selection
0215	C4-01	Torque compensation gain
0216	C4-02	Torque compensation delay time parameter
0217	C4-03	Starting torque compensation (FWD)
0218	C4-04	Starting torque compensation (REV)
0219	C4-05	Starting torque compensation time parameter
021A	C4-06	Torque compensation primary delay time 2
021B	C5-01	ASR proportional (P) gain 1
021C	C5-02	ASR integral (I) time 1
021D	C5-03	ASR proportional (P) gain 2
021E	C5-04	ASR integral (I) time 2
0220	C5-06	ASR primary delay time
0221	C5-07	ASR switching frequency
0222	C5-08	ASR integral (I) limit
022E	C5-09	ASR proportional (P) gain 3
0231	C5-10	ASR integral (I) time 3
0238	C5-15	ASR gain for encoder offset tuning
0224	C6-02	Carrier frequency selection
0225	C6-03	Carrier frequency upper limit
022B	C6-09	Carrier during rotational autotuning
022C	C6-10	Carrier during stationary autotuning
022D	C6-11	Carrier frequency selection 2
0280	d1-01	Frequency reference 1
0281	d1-02	Frequency reference 2
0282	d1-03	Frequency reference 3
0283	d1-04	Frequency reference 4
0284	d1-05	Frequency reference 5
0285	d1-06	Frequency reference 6
0286	d1-07	Frequency reference 7
0287	d1-08	Frequency reference 8
0288	d1-09	Nominal speed reference
028B	d1-10	Intermediate speed 1 reference
028C	d1-11	Intermediate speed 2 reference
028D	d1-12	Intermediate speed 3 reference
028E	d1-13	Releveling speed reference
028F	d1-14	Inspection speed reference
0292	d1-17	Leveling speed reference
02A7	d1-18	Speed priority selection
02A2	d6-03	Field forcing function selection
02A5	d6-06	Field forcing limit value
0300	E1-01	Input voltage setting
0302	E1-03	V/f pattern selection
0303	E1-04	Max. output frequency (FMAX)
0304	E1-05	Max. output voltage (VMAX)
0305	E1-06	Base frequency (FA)
0306	E1-07	Mid. output frequency (FB)
0307	E1-08	Mid. Output frequency voltage (VB)
0308	E1-09	Min. output frequency (FMIN)
0309	E1-10	Min. output frequency voltage (VMIN)
030C	E1-13	Base voltage (VBASE)
030E	E2-01	Motor rated current
030F	E2-02	Motor rated slip
0310	E2-03	Motor noload current
0311	E2-04	Number of motor poles
0312	E2-05	Motor line-to-line resistance
0313	E2-06	Motor leak inductance
0314	E2-07	Motor iron saturation coefficient 1
0315	E2-08	Motor iron saturation coefficient 2
0316	E2-09	Motor mechanical loss
0317	E2-10	Motor iron loss for torque compensation
0318	E2-11	Motor rated output power
0328	E2-12	Motor iron saturation coefficient 3
032A	E5-02	Motor rated power
032B	E5-03	Motor rated current
032C	E5-04	Number of motor poles
032D	E5-05	Motor line-to-line resistance
032E	E5-06	d-axis inductance
032F	E5-07	q-axis inductance
0331	E5-09	Motor voltage parameter
0333	E5-11	PG home position offset
0380	F1-01	PG constant
0381	F1-02	Operation selection at PG open circuit (PGO)
0382	F1-03	Operation selection at overspeed (OS)
0383	F1-04	Operation selection at deviation
0384	F1-05	PG rotation
0385	F1-06	PG division rate (PG pulse monitor)
0387	F1-08	Overspeed detection level
0388	F1-09	Overspeed detection delay time
0389	F1-10	Excessive speed deviation detection level
038A	F1-11	Excessive speed deviation detection delay time
038D	F1-14	PG open-circuit detection time
03AD	F1-18	DV3 fault detection selection
03AE	F1-19	DV4 fault detection selection
03B0	F1-21	Absolute encoder resolution
03B1	F1-22	Magnet position offset
03B4	F1-25	Encoder copy selection
03B5	F1-26	Encoder copy write permission selection
0391	F4-01	Channel 1 monitor selection
0392	F4-02	Channel 1 gain
0393	F4-03	Channel 2 monitor selection
0394	F4-04	Channel 2 gain
0395	F4-05	Channel 1 output monitor bias
0396	F4-06	Channel 2 output monitor bias
0397	F4-07	Analog output signal level for channel 1
0398	F4-08	Analog output signal level for channel 2
0399	F5-01	Channel 1 output selection
039A	F5-02	Channel 2 output selection
039B	F5-03	Channel 3 output selection
039C	F5-04	Channel 4 output selection
039D	F5-05	Channel 5 output selection
039E	F5-06	Channel 6 output selection
039F	F5-07	Channel 7 output selection
03A0	F5-08	Channel 8 output selection
03A1	F5-09	DO-08 output mode selection
03A2	F6-01	Operation selection after communications error
03A3	F6-02	Input level of external fault from communications option card
03A4	F6-03	Stopping method for external fault from communications option card
03A5	F6-04	Trace sampling from communications option card
03A6	F6-05	Current monitor unit selection
03A7	F6-06	Torque reference/torque limit selection from communications option card
0400	H1-01	Terminal S3 function selection
0401	H1-02	Terminal S4 function selection
0402	H1-03	Terminal S5 function selection
0403	H1-04	Terminal S6 function selection
0404	H1-05	Terminal S7 function selection
040B	H2-01	Terminal M1-M2 function selection
040C	H2-02	Terminal M3-M4 function selection
040D	H2-03	Terminal M5-M6 function selection
0410	H3-01	AI-14B Channel 1 signal level selection
0411	H3-02	AI-14B Channel 1 gain
0412	H3-03	AI-14B Channel 1 bias
0413	H3-04	AI-14B Channel 3 signal level selection
0414	H3-05	AI-14B Channel 3 function selection
0415	H3-06	AI-14B Channel 3 gain
0416	H3-07	AI-14B Channel 3 bias
0417	H3-08	AI-14B Channel 2 signal level selection
0418	H3-09	AI-14B Channel 2 function selection
0419	H3-10	AI-14B Channel 2 gain
041A	H3-11	AI-14B Channel 2 bias
041B	H3-12	Analog input filter time parameter
0434	H3-15	Terminal A1 function selection
0435	H3-16	Terminal A1 input gain
0436	H3-17	Terminal A1 input bias
0425	H5-01	Slave address
0426	H5-02	Communication speed selection
0427	H5-03	Communication parity selection
0428	H5-04	Stopping method after communication error
0429	H5-05	Communication error detection selection
042A	H5-06	Send wait time
042B	H5-07	RTS control ON/OFF
0480	L1-01	Motor protection selection
0481	L1-02	Motor protection time constant
0489	L2-05	Undervoltage detection level
04CB	L2-11	Battery Voltage
048F	L3-01	Stall prevention selection during accel
0490	L3-02	Stall prevention level during accel
0491	L3-03	Stall prevention limit during accel
0492	L3-04	Stall prevention selection during decel
0493	L3-05	Stall prevention selection during running
0494	L3-06	Stall prevention level during running
0499	L4-01	Speed agreement detection level
049A	L4-02	Speed agreement detection width
049B	L4-03	Speed agreement detection level (+/-)
049C	L4-04	Speed agreement detection width (+/-)
049D	L4-05	Operation when frequency reference is missing
04C2	L4-06	Frequency reference when frequency reference is lost
049E	L5-01	Number of auto restart attempts
049F	L5-02	Auto restart operation selection
04A0	L5-03	Abnormal retry interval time
04CC	L5-05	Under voltage fault restart selection
04A1	L6-01	Torque detection selection 1
04A2	L6-02	Torque detection level 1
04A3	L6-03	Torque detection time 1
04A4	L6-04	Torque detection selection 2
04A5	L6-05	Torque detection level 2
04A6	L6-06	Torque detection time 2
04A7	L7-01	Forward drive torque limit
04A8	L7-02	Reverse drive torque limit
04A9	L7-03	Forward regenerative torque limit
04AA	L7-04	Reverse regenerative torque limit
04AC	L7-06	Torque limit time parameter
04C9	L7-07	Torque Limit Operation during accel/decel
04AE	L8-02	Overheat pre-alarm level
04AF	L8-03	Operation selection after overheat prealarm
04B1	L8-05	Input openphase protection selection
04B3	L8-07	Output open-phase protection selection
04B5	L8-09	Ground fault detection selection
04B6	L8-10	Cooling fan control selection
04B7	L8-11	Cooling fan control delay time
04B8	L8-12	Ambient temperature
04BE	L8-18	Soft CLA selection
04C0	L8-20	Output phase loss detection time
04E2	L8-32	OH1 detection during cooling fan failure
0584	N2-01	Speed feedback detection control (AFR) gain
0585	N2-02	Speed feedback detection control (AFR) time constant
0586	N2-03	Speed feedback detection control (AFR) time constant 2
05B0	N5-01	Feed forward control selection
05B1	N5-02	Motor acceleration time
05B2	N5-03	Feed forward proportional gain
0540	N8-01	Initial magnetic polarity estimation current
0562	N8-35	Magnet position detection method
0563	N8-36	Magnet position detection method 2 frequency
0564	N8-37	Magnet position detection method 2 current level
0566	N8-39	Low pass filter cut-off frequency for magnet position detection method 2
056D	N8-46	Inductance measurement current level
064D	N9-60	A/D conversion start delay time
065B	N9-74	Leakage current reduction selection
0500	o1-01	Monitor selection
0501	o1-02	Monitor selection after power up
0502	o1-03	Frequency units of reference setting and monitor
0503	o1-04	Setting unit for frequency constants related to V/f characteristics
0504	o1-05	LCD Display contrast adjustment
0505	o2-01	LOCAL/REMOTE key enable/disable
0506	o2-02	STOP key during control circuit terminal operation
0507	o2-03	Parameter initial value
0508	o2-04	kVA selection
0509	o2-05	Frequency reference setting method selection
050A	o2-06	Operation selection when digital operator is disconnected
050B	o2-07	Cumulative operation time setting
050C	o2-08	Cumulative operation time selection
050D	o2-09	Initialization mode
050E	o2-10	Fan operation time setting
0510	o2-12	Fault trace initialize
0513	o2-15	Number of Travels counter initialize
0515	o3-01	Copy function selection
0516	o3-02	Read permitted selection
0680	S1-01	Zero speed level at stop
0681	S1-02	DC injection braking current at start
0682	S1-03	DC injection braking current at stop
0683	S1-04	DC injection braking/zerospeed time at start
0684	S1-05	DC injection braking/zerospeed time at stop
0685	S1-06	Brake release delay time
0686	S1-07	Brake close delay time
068D	S1-14	SE2 detection delay time
068E	S1-15	SE3 detection delay time
068F	S1-16	Run delay time
0690	S1-17	DC injection current gain at regenerative operation
0691	S1-18	DC injection current gain at motoring operation
0692	S1-19	Magnetic contactor open delay time
0693	S1-20	Zero servo gain
0694	S1-21	Zero-servo completion width
0695	S1-22	Starting torque compensation increase time
0696	S1-23	Torque compensation gain during lowering
0697	S1-24	Torque compensation bias during raising
0698	S1-25	Torque compensation bias during lowering
0699	S1-26	Torque compensation gain during lowering
069A	S1-27	Door zone speed level
069B	S1-28	SE1 selection
069E	S1-31	Torque limit time at stop
06AE	S2-01	Motor rated speed
06AF	S2-02	Slip compensation gain in motoring mode
06B0	S2-03	Slip compensation gain in regenerative mode
06B4	S2-07	Slip compensation delay time
06BC	S2-15	Slip compensation selection during regeneration
06BD	S3-01	Short floor function selection
06C4	S3-08	Output phase order
06C5	S3-09	Frequency reference loss fault detection
06C9	S3-13	Traction sheave diameter
06CA	S3-14	Roping
06CC	S3-16	Over acceleration detection level
06CD	S3-17	Over acceleration detection filter time
06CE	S3-18	Over acceleration detection selection
06D3	S3-23	Distance calculation deceleration time gain
0701	T1-01	Autotuning mode selection
0702	T1-02	Motor output power
0703	T1-03	Motor rated voltage
0704	T1-04	Motor rated current
0705	T1-05	Motor base frequency
0706	T1-06	Number of motor poles
0707	T1-07	Motor base speed
0708	T1-08	Number of PG pulses
0709	T1-09	Motor noload current
0730	T2-01	Motor output power
0731	T2-02	Motor base frequency
0732	T2-03	Motor rated voltage
0733	T2-04	Motor rated current
0734	T2-05	Number of motor poles
0735	T2-06	Motor d axis inductance
0737	T2-08	Motor voltage parameter
0738	T2-09	Number of PG pulses
072F	T2-10	Motor voltage parameter calculation selection
0040	U1-01	Frequency reference
0041	U1-02	Output frequency
0042	U1-03	Output current
0043	U1-04	Control method
0044	U1-05	Motor speed
0045	U1-06	Output voltage
0046	U1-07	DC bus voltage
0047	U1-08	Output power
0048	U1-09	Torque reference
0049.0	U1-10	1:FWD command(S1) is ON (Input terminal status)
0049.1	U1-10	1:REV command(S2) is ON (Input terminal status)
0049.2	U1-10	1:Multi input 1(S3) is ON (Input terminal status)
0049.3	U1-10	1:Multi input 2(S4) is ON (Input terminal status)
0049.4	U1-10	1:Multi input 3(S5) is ON (Input terminal status)
0049.5	U1-10	1:Multi input 4(S6) is ON (Input terminal status)
0049.6	U1-10	1:Multi input 5(S7) is ON (Input terminal status)
004A.0	U1-11	1:Multi-function contact output 1(M1-M2) is ON (Output terminal status)
004A.1	U1-11	1:Multi-function contact output 2(M3-M4) is ON (Output terminal status)
004A.2	U1-11	1:Multi-function contact output 3(M5-M6) is ON (Output terminal status)
004A.8	U1-11	1:Error output(MA/MB-MC) (Output terminal status)
004B.0	U1-12	1:Run (Operation status)
004B.1	U1-12	1:Zero speed (Operation status)
004B.2	U1-12	1:Reverse (Operation status)
004B.3	U1-12	1:Reset signal input (Operation status)
004B.4	U1-12	1:Speed agree (Operation status)
004B.5	U1-12	1:Inverter ready (Operation status)
004B.6	U1-12	1:Minor fault (Operation status)
004B.7	U1-12	1:Major fault (Operation status)
004C	U1-13	Cumulative operation time
004D	U1-14	Software No. (flash memory)
004E	U1-15	Terminal A1 or A1-14B channel 1 input voltage level
004F	U1-16	AI-14B channel 2 input voltage level
0050	U1-17	AI-14B channel 3 input voltage level
0051	U1-18	Motor secondary current (Iq)
0052	U1-19	Motor exciting current (Id)
0053	U1-20	Frequency reference after softstarter
0054	U1-21	ASR input
0055	U1-22	ASR output
0058	U1-25	DI-16H2 input status
0059	U1-26	Output voltage reference (Vq)
005A	U1-27	Output voltage reference (Vd)
005B	U1-28	Software No. (CPU)
005F	U1-32	ACR output of q axis
0060	U1-33	ACR output of d axis
0061	U1-34	OPE fault constant
0062	U1-35	Zero-servo movement pulses
0066.0	U1-39	1:CRC error (MEMOBUS communications error code)
0066.1	U1-39	1:Data length error (MEMOBUS communications error code)
0066.3	U1-39	1:Parity error (MEMOBUS communications error code)
0066.4	U1-39	1:Overrun error (MEMOBUS communications error code)
0066.5	U1-39	1:Framing error (MEMOBUS communications error code)
0066.6	U1-39	1:Timeout (MEMOBUS communications error code)
0067	U1-40	Cooling fan operating time
0068	U1-41	Heatsink Temperature
006B	U1-44	ASR output without filter
006C	U1-45 	Feed forward control output
0071	U1-50	Slip compensation value
0072	U1-51	Max Current during acceleration
0073	U1-52	Max Current during deceleration
0074	U1-53	Max Current during Top speed
0075	U1-54	Max Current during leveling speed
0076	U1-55	Operation counter
0077	U1-56	AI-14B channel 1 input voltage level
0078	U1-57	Car acceleration rate
07C6	U1-74	q-axis motor current reference
07C7	U1-75	d-axis motor current reference
0080	U2-01	Current fault
0081	U2-02	Last fault
0082	U2-03	Reference frequency at fault
0083	U2-04	Output frequency at fault
0084	U2-05	Output current at fault
0085	U2-06	Motor speed at fault
0086	U2-07	Output voltage reference at fault
0087	U2-08	DC bus voltage at fault
0088	U2-09	Output power at fault
0089	U2-10	Torque reference at fault
008A	U2-11	Input terminal status at fault
008B	U2-12	Output terminal status at fault
008C	U2-13	Operation status at fault
008D	U2-14	Cumulative operation time at fault
07E0	U2-15	Soft Starter Speed Reference at Fault
07E1	U2-16	q-Axis Current at Fault
07E2	U2-17	d-Axis Current at Fault
0090	U3-01	Last fault
0091	U3-02	Second last fault
0092	U3-03	Third last fault
0093	U3-04	Fourth last fault
0094	U3-05	Cumulative operation time at fault
0095	U3-06	Accumulated time of second fault
0096	U3-07	Accumulated time of third fault
0097	U3-08	Accumulated time of fourth fault
0804	U3-09	Fifth last fault
0805	U3-10	Sixth last fault
0806	U3-11	Seventh last fault
0807	U3-12	Eighth last fault
0808	U3-13	Ninth last fault
0809	U3-14	Tenth last fault
080E	U3-15	Accumulated time of fifth fault
080F	U3-16	Accumulated time of sixth fault
0810	U3-17	Accumulated time of secenth fault
0811	U3-18	Accumulated time of eighth fault
0812	U3-19	Accumulated time of ninth fault
0813	U3-20	Accumulated time of tenth fault
0800	U3-01	Last fault
0801	U3-02	Second last fault
0802	U3-03	Third last fault
0803	U3-04	Fourth last fault
080A	U3-05	Cumulative operation time at fault
080B	U3-06	Accumulated time of second fault
080C	U3-07	Accumulated time of third fault
080D	U3-08	Accumulated time of fourth fault
[SigDataEnd]-B