﻿Name=PLC1
UT2000
MaxSigCnt=0
DataFormat=Dec

[D-SigData]
1D0001	STATUS
1D0002	1.ERROR [CH1]
1D0003	2.ERROR [CH2]
1D0004	3.ERROR [CH3]
1D0005	4.ERROR [CH4]
1D0006	1.PV (Process value) [CH1]
1D0007	2.PV (Process value) [CH2]
1D0008	3.PV (Process value) [CH3]
1D0009	4.PV (Process value) [CH4]
1D0010	1.CSP (Current target setpoint) [CH1]
1D0011	2.CSP (Current target setpoint) [CH2]
1D0012	3.CSP (Current target setpoint) [CH3]
1D0013	4.CSP (Current target setpoint) [CH4]
1D0014	1.OUT (Output value) [CH1]
1D0015	2.OUT (Output value) [CH2]
1D0016	3.OUT (Output value) [CH3]
1D0017	4.OUT (Output value) [CH4]
1D0018	1.MOD (Mode status) [CH1]
1D0019	2.MOD (Mode status) [CH2]
1D0020	3.MOD (Mode status) [CH3]
1D0021	4.MOD (Mode status) [CH4]
1D0022	1.DEV (Deviation) [CH1]
1D0023	2.DEV (Deviation) [CH2]
1D0024	3.DEV (Deviation) [CH3]
1D0025	4.DEV (Deviation) [CH4]
1D0026	1.SPNO (Set group number) [CH1]
1D0027	2.SPNO (Set group number) [CH2]
1D0028	3.SPNO (Set group number) [CH3]
1D0029	4.SPNO (Set group number) [CH4]
1D0030	1.HC (Heater current value) [CH1]
1D0031	2.HC (Heater current value) [CH2]
1D0032	3.HC (Heater current value) [CH3]
1D0033	4.HC (Heater current value) [CH4]
1D0090	(REG SL)
1D0091	(100%)
1D0092	(75%)
1D0093	(50%)
1D0094	(25%)
1D0095	(0%)
1D0110	1.SP (Target setpoint) [1CH Operation data]
1D0111	1.A1 (Alarm setpoints for alarm 1) [1CH Operation data]
1D0112	1.A2 (Alarm setpoints for alarm 2) [1CH Operation data]
1D0113	1.PB (Proportional band) [1CH Operation data]
1D0114	1.TI (Integral time) [1CH Operation data]
1D0115	1.TD (Derivative time) [1CH Operation data]
1D0116	1.MR (Manual reset) [1CH Operation data]
1D0117	1.HYS (Hysteresis) [1CH Operation data]
1D0118	1.DR (Direct/reverse action switching) [1CH Operation data]
1D0120	2.SP (Target setpoint) [1CH Operation data]
1D0121	2.A1 (Alarm setpoints for alarm 1) [1CH Operation data]
1D0122	2.A2 (Alarm setpoints for alarm 2) [1CH Operation data]
1D0123	2.PB (Proportional band) [1CH Operation data]
1D0124	2.TI (Integral time) [1CH Operation data]
1D0125	2.TD (Derivative time) [1CH Operation data]
1D0126	2.MR (Manual reset) [1CH Operation data]
1D0127	2.HYS (Hysteresis) [1CH Operation data]
1D0128	2.DR (Direct/reverse action switching) [1CH Operation data]
1D0130	3.SP (Target setpoint) [1CH Operation data]
1D0131	3.A1 (Alarm setpoints for alarm 1) [1CH Operation data]
1D0132	3.A2 (Alarm setpoints for alarm 2) [1CH Operation data]
1D0133	3.PB (Proportional band) [1CH Operation data]
1D0134	3.TI (Integral time) [1CH Operation data]
1D0135	3.TD (Derivative time) [1CH Operation data]
1D0136	3.MR (Manual reset) [1CH Operation data]
1D0137	3.HYS (Hysteresis) [1CH Operation data]
1D0138	3.DR (Direct/reverse action switching) [1CH Operation data]
1D0140	4.SP (Target setpoint) [1CH Operation data]
1D0141	4.A1 (Alarm setpoints for alarm 1) [1CH Operation data]
1D0142	4.A2 (Alarm setpoints for alarm 2) [1CH Operation data]
1D0143	4.PB (Proportional band) [1CH Operation data]
1D0144	4.TI (Integral time) [1CH Operation data]
1D0145	4.TD (Derivative time) [1CH Operation data]
1D0146	4.MR (Manual reset) [1CH Operation data]
1D0147	4.HYS (Hysteresis) [1CH Operation data]
1D0148	4.DR (Direct/reverse action switching) [1CH Operation data]
1D0150	5.SP (Target setpoint) [1CH Operation data]
1D0151	5.A1 (Alarm setpoints for alarm 1) [1CH Operation data]
1D0152	5.A2 (Alarm setpoints for alarm 2) [1CH Operation data]
1D0153	5.PB (Proportional band) [1CH Operation data]
1D0154	5.TI (Integral time) [1CH Operation data]
1D0155	5.TD (Derivative time) [1CH Operation data]
1D0156	5.MR (Manual reset) [1CH Operation data]
1D0157	5.HYS (Hysteresis) [1CH Operation data]
1D0158	5.DR (Direct/reverse action switching) [1CH Operation data]
1D0160	6.SP (Target setpoint) [1CH Operation data]
1D0161	6.A1 (Alarm setpoints for alarm 1) [1CH Operation data]
1D0162	6.A2 (Alarm setpoints for alarm 2) [1CH Operation data]
1D0163	6.PB (Proportional band) [1CH Operation data]
1D0164	6.TI (Integral time) [1CH Operation data]
1D0165	6.TD (Derivative time) [1CH Operation data]
1D0166	6.MR (Manual reset) [1CH Operation data]
1D0167	6.HYS (Hysteresis) [1CH Operation data]
1D0168	6.DR (Direct/reverse action switching) [1CH Operation data]
1D0170	7.SP (Target setpoint) [1CH Operation data]
1D0171	7.A1 (Alarm setpoints for alarm 1) [1CH Operation data]
1D0172	7.A2 (Alarm setpoints for alarm 2) [1CH Operation data]
1D0173	7.PB (Proportional band) [1CH Operation data]
1D0174	7.TI (Integral time) [1CH Operation data]
1D0175	7.TD (Derivative time) [1CH Operation data]
1D0176	7.MR (Manual reset) [1CH Operation data]
1D0177	7.HYS (Hysteresis) [1CH Operation data]
1D0178	7.DR (Direct/reverse action switching) [1CH Operation data]
1D0180	8.SP (Target setpoint) [1CH Operation data]
1D0181	8.A1 (Alarm setpoints for alarm 1) [1CH Operation data]
1D0182	8.A2 (Alarm setpoints for alarm 2) [1CH Operation data]
1D0183	8.PB (Proportional band) [1CH Operation data]
1D0184	8.TI (Integral time) [1CH Operation data]
1D0185	8.TD (Derivative time) [1CH Operation data]
1D0186	8.MR (Manual reset) [1CH Operation data]
1D0187	8.HYS (Hysteresis) [1CH Operation data]
1D0188	8.DR (Direct/reverse action switching) [1CH Operation data]
1D0210	1.SP (Target setpoint) [2CH Operation data]
1D0211	1.A1 (Alarm setpoints for alarm 1) [2CH Operation data]
1D0212	1.A2 (Alarm setpoints for alarm 2) [2CH Operation data]
1D0213	1.PB (Proportional band) [2CH Operation data]
1D0214	1.TI (Integral time) [2CH Operation data]
1D0215	1.TD (Derivative time) [2CH Operation data]
1D0216	1.MR (Manual reset) [2CH Operation data]
1D0217	1.HYS (Hysteresis) [2CH Operation data]
1D0218	1.DR (Direct/reverse action switching) [2CH Operation data]
1D0220	2.SP (Target setpoint) [2CH Operation data]
1D0221	2.A1 (Alarm setpoints for alarm 1) [2CH Operation data]
1D0222	2.A2 (Alarm setpoints for alarm 2) [2CH Operation data]
1D0223	2.PB (Proportional band) [2CH Operation data]
1D0224	2.TI (Integral time) [2CH Operation data]
1D0225	2.TD (Derivative time) [2CH Operation data]
1D0226	2.MR (Manual reset) [2CH Operation data]
1D0227	2.HYS (Hysteresis) [2CH Operation data]
1D0228	2.DR (Direct/reverse action switching) [2CH Operation data]
1D0230	3.SP (Target setpoint) [2CH Operation data]
1D0231	3.A1 (Alarm setpoints for alarm 1) [2CH Operation data]
1D0232	3.A2 (Alarm setpoints for alarm 2) [2CH Operation data]
1D0233	3.PB (Proportional band) [2CH Operation data]
1D0234	3.TI (Integral time) [2CH Operation data]
1D0235	3.TD (Derivative time) [2CH Operation data]
1D0236	3.MR (Manual reset) [2CH Operation data]
1D0237	3.HYS (Hysteresis) [2CH Operation data]
1D0238	3.DR (Direct/reverse action switching) [2CH Operation data]
1D0240	4.SP (Target setpoint) [2CH Operation data]
1D0241	4.A1 (Alarm setpoints for alarm 1) [2CH Operation data]
1D0242	4.A2 (Alarm setpoints for alarm 2) [2CH Operation data]
1D0243	4.PB (Proportional band) [2CH Operation data]
1D0244	4.TI (Integral time) [2CH Operation data]
1D0245	4.TD (Derivative time) [2CH Operation data]
1D0246	4.MR (Manual reset) [2CH Operation data]
1D0247	4.HYS (Hysteresis) [2CH Operation data]
1D0248	4.DR (Direct/reverse action switching) [2CH Operation data]
1D0250	5.SP (Target setpoint) [2CH Operation data]
1D0251	5.A1 (Alarm setpoints for alarm 1) [2CH Operation data]
1D0252	5.A2 (Alarm setpoints for alarm 2) [2CH Operation data]
1D0253	5.PB (Proportional band) [2CH Operation data]
1D0254	5.TI (Integral time) [2CH Operation data]
1D0255	5.TD (Derivative time) [2CH Operation data]
1D0256	5.MR (Manual reset) [2CH Operation data]
1D0257	5.HYS (Hysteresis) [2CH Operation data]
1D0258	5.DR (Direct/reverse action switching) [2CH Operation data]
1D0260	6.SP (Target setpoint) [2CH Operation data]
1D0261	6.A1 (Alarm setpoints for alarm 1) [2CH Operation data]
1D0262	6.A2 (Alarm setpoints for alarm 2) [2CH Operation data]
1D0263	6.PB (Proportional band) [2CH Operation data]
1D0264	6.TI (Integral time) [2CH Operation data]
1D0265	6.TD (Derivative time) [2CH Operation data]
1D0266	6.MR (Manual reset) [2CH Operation data]
1D0267	6.HYS (Hysteresis) [2CH Operation data]
1D0268	6.DR (Direct/reverse action switching) [2CH Operation data]
1D0270	7.SP (Target setpoint) [2CH Operation data]
1D0271	7.A1 (Alarm setpoints for alarm 1) [2CH Operation data]
1D0272	7.A2 (Alarm setpoints for alarm 2) [2CH Operation data]
1D0273	7.PB (Proportional band) [2CH Operation data]
1D0274	7.TI (Integral time) [2CH Operation data]
1D0275	7.TD (Derivative time) [2CH Operation data]
1D0276	7.MR (Manual reset) [2CH Operation data]
1D0277	7.HYS (Hysteresis) [2CH Operation data]
1D0278	7.DR (Direct/reverse action switching) [2CH Operation data]
1D0280	8.SP (Target setpoint) [2CH Operation data]
1D0281	8.A1 (Alarm setpoints for alarm 1) [2CH Operation data]
1D0282	8.A2 (Alarm setpoints for alarm 2) [2CH Operation data]
1D0283	8.PB (Proportional band) [2CH Operation data]
1D0284	8.TI (Integral time) [2CH Operation data]
1D0285	8.TD (Derivative time) [2CH Operation data]
1D0286	8.MR (Manual reset) [2CH Operation data]
1D0287	8.HYS (Hysteresis) [2CH Operation data]
1D0288	8.DR (Direct/reverse action switching) [2CH Operation data]
1D0310	1.SP (Target setpoint) [3CH Operation data]
1D0311	1.A1 (Alarm setpoints for alarm 1) [3CH Operation data]
1D0312	1.A2 (Alarm setpoints for alarm 2) [3CH Operation data]
1D0313	1.PB (Proportional band) [3CH Operation data]
1D0314	1.TI (Integral time) [3CH Operation data]
1D0315	1.TD (Derivative time) [3CH Operation data]
1D0316	1.MR (Manual reset) [3CH Operation data]
1D0317	1.HYS (Hysteresis) [3CH Operation data]
1D0318	1.DR (Direct/reverse action switching) [3CH Operation data]
1D0320	2.SP (Target setpoint) [3CH Operation data]
1D0321	2.A1 (Alarm setpoints for alarm 1) [3CH Operation data]
1D0322	2.A2 (Alarm setpoints for alarm 2) [3CH Operation data]
1D0323	2.PB (Proportional band) [3CH Operation data]
1D0324	2.TI (Integral time) [3CH Operation data]
1D0325	2.TD (Derivative time) [3CH Operation data]
1D0326	2.MR (Manual reset) [3CH Operation data]
1D0327	2.HYS (Hysteresis) [3CH Operation data]
1D0328	2.DR (Direct/reverse action switching) [3CH Operation data]
1D0330	3.SP (Target setpoint) [3CH Operation data]
1D0331	3.A1 (Alarm setpoints for alarm 1) [3CH Operation data]
1D0332	3.A2 (Alarm setpoints for alarm 2) [3CH Operation data]
1D0333	3.PB (Proportional band) [3CH Operation data]
1D0334	3.TI (Integral time) [3CH Operation data]
1D0335	3.TD (Derivative time) [3CH Operation data]
1D0336	3.MR (Manual reset) [3CH Operation data]
1D0337	3.HYS (Hysteresis) [3CH Operation data]
1D0338	3.DR (Direct/reverse action switching) [3CH Operation data]
1D0340	4.SP (Target setpoint) [3CH Operation data]
1D0341	4.A1 (Alarm setpoints for alarm 1) [3CH Operation data]
1D0342	4.A2 (Alarm setpoints for alarm 2) [3CH Operation data]
1D0343	4.PB (Proportional band) [3CH Operation data]
1D0344	4.TI (Integral time) [3CH Operation data]
1D0345	4.TD (Derivative time) [3CH Operation data]
1D0346	4.MR (Manual reset) [3CH Operation data]
1D0347	4.HYS (Hysteresis) [3CH Operation data]
1D0348	4.DR (Direct/reverse action switching) [3CH Operation data]
1D0350	5.SP (Target setpoint) [3CH Operation data]
1D0351	5.A1 (Alarm setpoints for alarm 1) [3CH Operation data]
1D0352	5.A2 (Alarm setpoints for alarm 2) [3CH Operation data]
1D0353	5.PB (Proportional band) [3CH Operation data]
1D0354	5.TI (Integral time) [3CH Operation data]
1D0355	5.TD (Derivative time) [3CH Operation data]
1D0356	5.MR (Manual reset) [3CH Operation data]
1D0357	5.HYS (Hysteresis) [3CH Operation data]
1D0358	5.DR (Direct/reverse action switching) [3CH Operation data]
1D0360	6.SP (Target setpoint) [3CH Operation data]
1D0361	6.A1 (Alarm setpoints for alarm 1) [3CH Operation data]
1D0362	6.A2 (Alarm setpoints for alarm 2) [3CH Operation data]
1D0363	6.PB (Proportional band) [3CH Operation data]
1D0364	6.TI (Integral time) [3CH Operation data]
1D0365	6.TD (Derivative time) [3CH Operation data]
1D0366	6.MR (Manual reset) [3CH Operation data]
1D0367	6.HYS (Hysteresis) [3CH Operation data]
1D0368	6.DR (Direct/reverse action switching) [3CH Operation data]
1D0370	7.SP (Target setpoint) [3CH Operation data]
1D0371	7.A1 (Alarm setpoints for alarm 1) [3CH Operation data]
1D0372	7.A2 (Alarm setpoints for alarm 2) [3CH Operation data]
1D0373	7.PB (Proportional band) [3CH Operation data]
1D0374	7.TI (Integral time) [3CH Operation data]
1D0375	7.TD (Derivative time) [3CH Operation data]
1D0376	7.MR (Manual reset) [3CH Operation data]
1D0377	7.HYS (Hysteresis) [3CH Operation data]
1D0378	7.DR (Direct/reverse action switching) [3CH Operation data]
1D0380	8.SP (Target setpoint) [3CH Operation data]
1D0381	8.A1 (Alarm setpoints for alarm 1) [3CH Operation data]
1D0382	8.A2 (Alarm setpoints for alarm 2) [3CH Operation data]
1D0383	8.PB (Proportional band) [3CH Operation data]
1D0384	8.TI (Integral time) [3CH Operation data]
1D0385	8.TD (Derivative time) [3CH Operation data]
1D0386	8.MR (Manual reset) [3CH Operation data]
1D0387	8.HYS (Hysteresis) [3CH Operation data]
1D0388	8.DR (Direct/reverse action switching) [3CH Operation data]
1D0410	1.SP (Target setpoint) [4CH Operation data]
1D0411	1.A1 (Alarm setpoints for alarm 1) [4CH Operation data]
1D0412	1.A2 (Alarm setpoints for alarm 2) [4CH Operation data]
1D0413	1.PB (Proportional band) [4CH Operation data]
1D0414	1.TI (Integral time) [4CH Operation data]
1D0415	1.TD (Derivative time) [4CH Operation data]
1D0416	1.MR (Manual reset) [4CH Operation data]
1D0417	1.HYS (Hysteresis) [4CH Operation data]
1D0418	1.DR (Direct/reverse action switching) [4CH Operation data]
1D0420	2.SP (Target setpoint) [4CH Operation data]
1D0421	2.A1 (Alarm setpoints for alarm 1) [4CH Operation data]
1D0422	2.A2 (Alarm setpoints for alarm 2) [4CH Operation data]
1D0423	2.PB (Proportional band) [4CH Operation data]
1D0424	2.TI (Integral time) [4CH Operation data]
1D0425	2.TD (Derivative time) [4CH Operation data]
1D0426	2.MR (Manual reset) [4CH Operation data]
1D0427	2.HYS (Hysteresis) [4CH Operation data]
1D0428	2.DR (Direct/reverse action switching) [4CH Operation data]
1D0430	3.SP (Target setpoint) [4CH Operation data]
1D0431	3.A1 (Alarm setpoints for alarm 1) [4CH Operation data]
1D0432	3.A2 (Alarm setpoints for alarm 2) [4CH Operation data]
1D0433	3.PB (Proportional band) [4CH Operation data]
1D0434	3.TI (Integral time) [4CH Operation data]
1D0435	3.TD (Derivative time) [4CH Operation data]
1D0436	3.MR (Manual reset) [4CH Operation data]
1D0437	3.HYS (Hysteresis) [4CH Operation data]
1D0438	3.DR (Direct/reverse action switching) [4CH Operation data]
1D0440	4.SP (Target setpoint) [4CH Operation data]
1D0441	4.A1 (Alarm setpoints for alarm 1) [4CH Operation data]
1D0442	4.A2 (Alarm setpoints for alarm 2) [4CH Operation data]
1D0443	4.PB (Proportional band) [4CH Operation data]
1D0444	4.TI (Integral time) [4CH Operation data]
1D0445	4.TD (Derivative time) [4CH Operation data]
1D0446	4.MR (Manual reset) [4CH Operation data]
1D0447	4.HYS (Hysteresis) [4CH Operation data]
1D0448	4.DR (Direct/reverse action switching) [4CH Operation data]
1D0450	5.SP (Target setpoint) [4CH Operation data]
1D0451	5.A1 (Alarm setpoints for alarm 1) [4CH Operation data]
1D0452	5.A2 (Alarm setpoints for alarm 2) [4CH Operation data]
1D0453	5.PB (Proportional band) [4CH Operation data]
1D0454	5.TI (Integral time) [4CH Operation data]
1D0455	5.TD (Derivative time) [4CH Operation data]
1D0456	5.MR (Manual reset) [4CH Operation data]
1D0457	5.HYS (Hysteresis) [4CH Operation data]
1D0458	5.DR (Direct/reverse action switching) [4CH Operation data]
1D0460	6.SP (Target setpoint) [4CH Operation data]
1D0461	6.A1 (Alarm setpoints for alarm 1) [4CH Operation data]
1D0462	6.A2 (Alarm setpoints for alarm 2) [4CH Operation data]
1D0463	6.PB (Proportional band) [4CH Operation data]
1D0464	6.TI (Integral time) [4CH Operation data]
1D0465	6.TD (Derivative time) [4CH Operation data]
1D0466	6.MR (Manual reset) [4CH Operation data]
1D0467	6.HYS (Hysteresis) [4CH Operation data]
1D0468	6.DR (Direct/reverse action switching) [4CH Operation data]
1D0470	7.SP (Target setpoint) [4CH Operation data]
1D0471	7.A1 (Alarm setpoints for alarm 1) [4CH Operation data]
1D0472	7.A2 (Alarm setpoints for alarm 2) [4CH Operation data]
1D0473	7.PB (Proportional band) [4CH Operation data]
1D0474	7.TI (Integral time) [4CH Operation data]
1D0475	7.TD (Derivative time) [4CH Operation data]
1D0476	7.MR (Manual reset) [4CH Operation data]
1D0477	7.HYS (Hysteresis) [4CH Operation data]
1D0478	7.DR (Direct/reverse action switching) [4CH Operation data]
1D0480	8.SP (Target setpoint) [4CH Operation data]
1D0481	8.A1 (Alarm setpoints for alarm 1) [4CH Operation data]
1D0482	8.A2 (Alarm setpoints for alarm 2) [4CH Operation data]
1D0483	8.PB (Proportional band) [4CH Operation data]
1D0484	8.TI (Integral time) [4CH Operation data]
1D0485	8.TD (Derivative time) [4CH Operation data]
1D0486	8.MR (Manual reset) [4CH Operation data]
1D0487	8.HYS (Hysteresis) [4CH Operation data]
1D0488	8.DR (Direct/reverse action switching) [4CH Operation data]
1D0510	1.SP (Target setpoint) [All CH1~CH4 setting]
1D0511	1.A1 (Alarm setpoints for alarm 1) [All CH1~CH4 setting]
1D0512	1.A2 (Alarm setpoints for alarm 2) [All CH1~CH4 setting]
1D0513	1.PB (Proportional band) [All CH1~CH4 setting]
1D0514	1.TI (Integral time) [All CH1~CH4 setting]
1D0515	1.TD (Derivative time) [All CH1~CH4 setting]
1D0516	1.MR (Manual reset) [All CH1~CH4 setting]
1D0517	1.HYS (Hysteresis) [All CH1~CH4 setting]
1D0518	1.DR (Direct/reverse action switching) [All CH1~CH4 setting]
1D0520	2.SP (Target setpoint) [All CH1~CH4 setting]
1D0521	2.A1 (Alarm setpoints for alarm 1) [All CH1~CH4 setting]
1D0522	2.A2 (Alarm setpoints for alarm 2) [All CH1~CH4 setting]
1D0523	2.PB (Proportional band) [All CH1~CH4 setting]
1D0524	2.TI (Integral time) [All CH1~CH4 setting]
1D0525	2.TD (Derivative time) [All CH1~CH4 setting]
1D0526	2.MR (Manual reset) [All CH1~CH4 setting]
1D0527	2.HYS (Hysteresis) [All CH1~CH4 setting]
1D0528	2.DR (Direct/reverse action switching) [All CH1~CH4 setting]
1D0530	3.SP (Target setpoint) [All CH1~CH4 setting]
1D0531	3.A1 (Alarm setpoints for alarm 1) [All CH1~CH4 setting]
1D0532	3.A2 (Alarm setpoints for alarm 2) [All CH1~CH4 setting]
1D0533	3.PB (Proportional band) [All CH1~CH4 setting]
1D0534	3.TI (Integral time) [All CH1~CH4 setting]
1D0535	3.TD (Derivative time) [All CH1~CH4 setting]
1D0536	3.MR (Manual reset) [All CH1~CH4 setting]
1D0537	3.HYS (Hysteresis) [All CH1~CH4 setting]
1D0538	3.DR (Direct/reverse action switching) [All CH1~CH4 setting]
1D0540	4.SP (Target setpoint) [All CH1~CH4 setting]
1D0541	4.A1 (Alarm setpoints for alarm 1) [All CH1~CH4 setting]
1D0542	4.A2 (Alarm setpoints for alarm 2) [All CH1~CH4 setting]
1D0543	4.PB (Proportional band) [All CH1~CH4 setting]
1D0544	4.TI (Integral time) [All CH1~CH4 setting]
1D0545	4.TD (Derivative time) [All CH1~CH4 setting]
1D0546	4.MR (Manual reset) [All CH1~CH4 setting]
1D0547	4.HYS (Hysteresis) [All CH1~CH4 setting]
1D0548	4.DR (Direct/reverse action switching) [All CH1~CH4 setting]
1D0550	5.SP (Target setpoint) [All CH1~CH4 setting]
1D0551	5.A1 (Alarm setpoints for alarm 1) [All CH1~CH4 setting]
1D0552	5.A2 (Alarm setpoints for alarm 2) [All CH1~CH4 setting]
1D0553	5.PB (Proportional band) [All CH1~CH4 setting]
1D0554	5.TI (Integral time) [All CH1~CH4 setting]
1D0555	5.TD (Derivative time) [All CH1~CH4 setting]
1D0556	5.MR (Manual reset) [All CH1~CH4 setting]
1D0557	5.HYS (Hysteresis) [All CH1~CH4 setting]
1D0558	5.DR (Direct/reverse action switching) [All CH1~CH4 setting]
1D0560	6.SP (Target setpoint) [All CH1~CH4 setting]
1D0561	6.A1 (Alarm setpoints for alarm 1) [All CH1~CH4 setting]
1D0562	6.A2 (Alarm setpoints for alarm 2) [All CH1~CH4 setting]
1D0563	6.PB (Proportional band) [All CH1~CH4 setting]
1D0564	6.TI (Integral time) [All CH1~CH4 setting]
1D0565	6.TD (Derivative time) [All CH1~CH4 setting]
1D0566	6.MR (Manual reset) [All CH1~CH4 setting]
1D0567	6.HYS (Hysteresis) [All CH1~CH4 setting]
1D0568	6.DR (Direct/reverse action switching) [All CH1~CH4 setting]
1D0570	7.SP (Target setpoint) [All CH1~CH4 setting]
1D0571	7.A1 (Alarm setpoints for alarm 1) [All CH1~CH4 setting]
1D0572	7.A2 (Alarm setpoints for alarm 2) [All CH1~CH4 setting]
1D0573	7.PB (Proportional band) [All CH1~CH4 setting]
1D0574	7.TI (Integral time) [All CH1~CH4 setting]
1D0575	7.TD (Derivative time) [All CH1~CH4 setting]
1D0576	7.MR (Manual reset) [All CH1~CH4 setting]
1D0577	7.HYS (Hysteresis) [All CH1~CH4 setting]
1D0578	7.DR (Direct/reverse action switching) [All CH1~CH4 setting]
1D0580	8.SP (Target setpoint) [All CH1~CH4 setting]
1D0581	8.A1 (Alarm setpoints for alarm 1) [All CH1~CH4 setting]
1D0582	8.A2 (Alarm setpoints for alarm 2) [All CH1~CH4 setting]
1D0583	8.PB (Proportional band) [All CH1~CH4 setting]
1D0584	8.TI (Integral time) [All CH1~CH4 setting]
1D0585	8.TD (Derivative time) [All CH1~CH4 setting]
1D0586	8.MR (Manual reset) [All CH1~CH4 setting]
1D0587	8.HYS (Hysteresis) [All CH1~CH4 setting]
1D0588	8.DR (Direct/reverse action switching) [All CH1~CH4 setting]
1D0600	SC (SUPER function selection) [1CH Setup data]
1D0601	AT (Auto-tuning selection) [1CH Setup data]
1D0602	SP.UP (Setpoint ramp-up rate setting) [1CH Setup data]
1D0603	SP.DN (Setpoint ramp-down rate setting) [1CH Setup data]
1D0604	SP.R (Ramp-rate time unit setting) [1CH Setup data]
1D0605	FL (Filter) [1CH Setup data]
1D0606	BS (Input compensation bias) [1CH Setup data]
1D0607	A/M (AUTO/MAN modes) [1CH Setup data]
1D0608	R/S (STOP/RUN modes) [1CH Setup data]
1D0609	MANOUT (Manual output value) [1CH Setup data]
1D0610	PROUT (Preset output value) [1CH Setup data]
1D0611	SPNO (Group SP number) [1CH Setup data]
1D0612	HB (Heater current measurement) [1CH Setup data]
1D0613	AL1 (Alarm-1 type) [1CH Setup data]
1D0614	AL2 (Alarm-2 type) [1CH Setup data]
1D0615	HY1 (Alarm-1 hysteresis) [1CH Setup data]
1D0616	HY2 (Alarm-2 hysteresis) [1CH Setup data]
1D0617	CT (Cycle time) [1CH Setup data]
1D0618	OH (Upper limit of output) [1CH Setup data]
1D0619	OL (Lower limit of output) [1CH Setup data]
1D0620	RST (Restart mode) [1CH Setup data]
1D0621	ORBND (ON/OFF rate detection width) [1CH Setup data]
1D0622	ORHI (ON/OFF rate upper limit) [1CH Setup data]
1D0623	ORLO (ON/OFF rate lower limit) [1CH Setup data]
1D0624	USE (use/unuse) [1CH Setup data]
1D0625	A3 (Alarm-3 setpoint) [1CH Setup data]
1D0626	AL3 (Alarm-3 type) [1CH Setup data]
1D0627	HY3 (Alarm-3 hysteresis) [1CH Setup data]
1D0650	PD (Decimal point position) [1CH Setup data]
1D0651	RH (Instrument range upper limit) [1CH Setup data]
1D0652	RL (Instrument range lower limit) [1CH Setup data]
1D0653	ARSL (ARM action mode) [1CH Setup data]
1D0654	MD (Channel action mode) [1CH Setup data]
1D0700	SC (SUPER function selection) [2CH Setup data]
1D0701	AT (Auto-tuning selection) [2CH Setup data]
1D0702	SP.UP (Setpoint ramp-up rate setting) [2CH Setup data]
1D0703	SP.DN (Setpoint ramp-down rate setting) [2CH Setup data]
1D0704	SP.R (Rate time unit) [2CH Setup data]
1D0705	FL (Filter) [2CH Setup data]
1D0706	BS (Input compensation bias) [2CH Setup data]
1D0707	A/M (AUTO/MAN modes) [2CH Setup data]
1D0708	R/S (STOP/RUN modes) [2CH Setup data]
1D0709	MANOUT (ManualOutput value) [2CH Setup data]
1D0710	PROUT (PresetOutput value) [2CH Setup data]
1D0711	SPNO (Group SP number) [2CH Setup data]
1D0712	HB (Heater current measurement) [2CH Setup data]
1D0713	AL1 (Alarm-1 type) [2CH Setup data]
1D0714	AL2 (Alarm-2 type) [2CH Setup data]
1D0715	HY1 (Alarm-1 hysteresis) [2CH Setup data]
1D0716	HY2 (Alarm-2 hysteresis) [2CH Setup data]
1D0717	CT (Cycle time) [2CH Setup data]
1D0718	OH (Upper limit of output) [2CH Setup data]
1D0719	OL (Lower limit of output) [2CH Setup data]
1D0720	RST (Restart mode) [2CH Setup data]
1D0721	ORBND (ON/OFF rate detection width) [2CH Setup data]
1D0722	ORHI (ON/OFF rate upper limit) [2CH Setup data]
1D0723	ORLO (ON/OFF rate lower limit) [2CH Setup data]
1D0724	USE (use/unuse) [2CH Setup data]
1D0725	A3 (Alarm-3 setpoint) [2CH Setup data]
1D0726	AL3 (Alarm-3 type) [2CH Setup data]
1D0727	HY3 (Alarm-3 hysteresis) [2CH Setup data]
1D0750	PD (Decimal point position) [2CH Setup data]
1D0751	RH (Instrument range upper limit) [2CH Setup data]
1D0752	RL (Instrument range lower limit) [2CH Setup data]
1D0753	ARSL (ARM action mode) [2CH Setup data]
1D0754	MD (Channel action mode) [2CH Setup data]
1D0800	SC (SUPER function selection) [3CH Setup data]
1D0801	AT (Auto-tuning selection) [3CH Setup data]
1D0802	SP.UP (Setpoint ramp-up rate setting) [3CH Setup data]
1D0803	SP.DN (Setpoint ramp-down rate setting) [3CH Setup data]
1D0804	SP.R (Rate time unit) [3CH Setup data]
1D0805	FL (Filter) [3CH Setup data]
1D0806	BS (Input compensation bias) [3CH Setup data]
1D0807	A/M (AUTO/MAN modes) [3CH Setup data]
1D0808	R/S (STOP/RUN modes) [3CH Setup data]
1D0809	MANOUT (ManualOutput value) [3CH Setup data]
1D0810	PROUT (PresetOutput value) [3CH Setup data]
1D0811	SPNO (Group SP number) [3CH Setup data]
1D0812	HB (Heater current measurement) [3CH Setup data]
1D0813	AL1 (Alarm-1 type) [3CH Setup data]
1D0814	AL2 (Alarm-2 type) [3CH Setup data]
1D0815	HY1 (Alarm-1 hysteresis) [3CH Setup data]
1D0816	HY2 (Alarm-2 hysteresis) [3CH Setup data]
1D0817	CT (Cycle time) [3CH Setup data]
1D0818	OH (Upper limit of output) [3CH Setup data]
1D0819	OL (Lower limit of output) [3CH Setup data]
1D0820	RST (Restart mode) [3CH Setup data]
1D0821	ORBND (ON/OFF rate detection width) [3CH Setup data]
1D0822	ORHI (ON/OFF rate upper limit) [3CH Setup data]
1D0823	ORLO (ON/OFF rate lower limit) [3CH Setup data]
1D0824	USE (use/unuse) [3CH Setup data]
1D0825	A3 (Alarm-3 setpoint) [3CH Setup data]
1D0826	AL3 (Alarm-3 type) [3CH Setup data]
1D0827	HY3 (Alarm-3 hysteresis) [3CH Setup data]
1D0850	PD (Decimal point position) [3CH Setup data]
1D0851	RH (Instrument range upper limit) [3CH Setup data]
1D0852	RL (Instrument range lower limit) [3CH Setup data]
1D0853	ARSL (ARM action mode) [3CH Setup data]
1D0854	MD (Channel action mode) [3CH Setup data]
1D0900	SC (SUPER function selection) [4CH Setup data]
1D0901	AT (Auto-tuning selection) [4CH Setup data]
1D0902	SP.UP (Setpoint ramp-up rate setting) [4CH Setup data]
1D0903	SP.DN (Setpoint ramp-down rate setting) [4CH Setup data]
1D0904	SP.R (Rate time unit) [4CH Setup data]
1D0905	FL (Filter) [4CH Setup data]
1D0906	BS (Input compensation bias) [4CH Setup data]
1D0907	A/M (AUTO/MAN modes) [4CH Setup data]
1D0908	R/S (STOP/RUN modes) [4CH Setup data]
1D0909	MANOUT (Manual output value) [4CH Setup data]
1D0910	PROUT (Preset output value) [4CH Setup data]
1D0911	SPNO (Group SP number) [4CH Setup data]
1D0912	HB (Heater current measurement) [4CH Setup data]
1D0913	AL1 (Alarm-1 type) [4CH Setup data]
1D0914	AL2 (Alarm-2 type) [4CH Setup data]
1D0915	HY1 (Alarm-1 hysteresis) [4CH Setup data]
1D0916	HY2 (Alarm-2 hysteresis) [4CH Setup data]
1D0917	CT (Cycle time) [4CH Setup data]
1D0918	OH (Upper limit of output) [4CH Setup data]
1D0919	OL (Lower limit of output) [4CH Setup data]
1D0920	RST (Restart mode) [4CH Setup data]
1D0921	ORBND (ON/OFF rate detection width) [4CH Setup data]
1D0922	ORHI (ON/OFF rate upper limit) [4CH Setup data]
1D0923	ORLO (ON/OFF rate lower limit) [4CH Setup data]
1D0924	USE (use/unuse) [4CH Setup data]
1D0925	A3 (Alarm-3 setpoint) [4CH Setup data]
1D0926	AL3 (Alarm-3 type) [4CH Setup data]
1D0927	HY3 (Alarm-3 hysteresis) [4CH Setup data]
1D0950	PD (Decimal point position) [4CH Setup data]
1D0951	RH (Instrument range upper limit) [4CH Setup data]
1D0952	RL (Instrument range lower limit) [4CH Setup data]
1D0953	ARSL (ARM action mode) [4CH Setup data]
1D0954	MD (Channel action mode) [4CH Setup data]
1D0955	STEUP (Setup mode) [All CH Setup data]
1D0956	IN (Input type) [All CH Setup data]
1D1000	SC (SUPER function selection) [All CH1~CH4 setting]
1D1001	AT (Auto-tuning selection) [All CH1~CH4 setting]
1D1002	SP.UP (Setpoint ramp-up rate setting) [All CH1~CH4 setting]
1D1003	SP.DN (Setpoint ramp-down rate setting) [All CH1~CH4 setting]
1D1004	SP.R (Rate time unit) [All CH1~CH4 setting]
1D1005	FL (Filter) [All CH1~CH4 setting]
1D1006	BS (Input compensation bias) [All CH1~CH4 setting]
1D1007	A/M (AUTO/MAN modes) [All CH1~CH4 setting]
1D1008	R/S (STOP/RUN modes) [All CH1~CH4 setting]
1D1009	MANOUT (ManualOutput value) [All CH1~CH4 setting]
1D1010	PROUT (PresetOutput value) [All CH1~CH4 setting]
1D1011	SPNO (Group SP number) [All CH1~CH4 setting]
1D1012	HB (Heater current measurement) [All CH1~CH4 setting]
1D1013	AL1 (Alarm-1 type) [All CH1~CH4 setting]
1D1014	AL2 (Alarm-2 type) [All CH1~CH4 setting]
1D1015	HY1 (Alarm-1 hysteresis) [All CH1~CH4 setting]
1D1016	HY2 (Alarm-2 hysteresis) [All CH1~CH4 setting]
1D1017	CT (Cycle time) [All CH1~CH4 setting]
1D1018	OH (Upper limit of output) [All CH1~CH4 setting]
1D1019	OL (Lower limit of output) [All CH1~CH4 setting]
1D1020	RST (Restart mode) [All CH1~CH4 setting]
1D1021	ORBND (ON/OFF rate detection width) [All CH1~CH4 setting]
1D1022	ORHI (ON/OFF rate upper limit) [All CH1~CH4 setting]
1D1023	ORLO (ON/OFF rate lower limit) [All CH1~CH4 setting]
1D1024	USE (use/unuse) [All CH1~CH4 setting]
[D-SigDataEnd]

[D-SigData-2]
2D0001	STATUS
2D0002	5.ERROR [CH5]
2D0003	6.ERROR [CH6]
2D0004	7.ERROR [CH7]
2D0005	8.ERROR [CH8]
2D0006	5.PV (Process value) [CH5]
2D0007	6.PV (Process value) [CH6]
2D0008	7.PV (Process value) [CH7]
2D0009	8.PV (Process value) [CH8]
2D0010	5.CSP (Current target setpoint) [CH5]
2D0011	6.CSP (Current target setpoint) [CH6]
2D0012	7.CSP (Current target setpoint) [CH7]
2D0013	8.CSP (Current target setpoint) [CH8]
2D0014	5.OUT (Output value) [CH5]
2D0015	6.OUT (Output value) [CH6]
2D0016	7.OUT (Output value) [CH7]
2D0017	8.OUT (Output value) [CH8]
2D0018	5.MOD (Mode status) [CH5]
2D0019	6.MOD (Mode status) [CH6]
2D0020	7.MOD (Mode status) [CH7]
2D0021	8.MOD (Mode status) [CH8]
2D0022	5.DEV (Deviation) [CH5]
2D0023	6.DEV (Deviation) [CH6]
2D0024	7.DEV (Deviation) [CH7]
2D0025	8.DEV (Deviation) [CH8]
2D0026	5.SPNO (Set group number) [CH5]
2D0027	6.SPNO (Set group number) [CH6]
2D0028	7.SPNO (Set group number) [CH7]
2D0029	8.SPNO (Set group number) [CH8]
2D0030	5.HC (Heater current value) [CH5]
2D0031	6.HC (Heater current value) [CH6]
2D0032	7.HC (Heater current value) [CH7]
2D0033	8.HC (Heater current value) [CH8]
2D0090	(REG SL)
2D0091	(100%)
2D0092	(75%)
2D0093	(50%)
2D0094	(25%)
2D0095	(0%)
2D0110	1.SP (Target setpoint) [5CH Operation data]
2D0111	1.A1 (Alarm setpoints for alarm 1) [5CH Operation data]
2D0112	1.A2 (Alarm setpoints for alarm 2) [5CH Operation data]
2D0113	1.PB (Proportional band) [5CH Operation data]
2D0114	1.TI (Integral time) [5CH Operation data]
2D0115	1.TD (Derivative time) [5CH Operation data]
2D0116	1.MR (Manual reset) [5CH Operation data]
2D0117	1.HYS (Hysteresis) [5CH Operation data]
2D0118	1.DR (Direct/reverse action switching) [5CH Operation data]
2D0120	2.SP (Target setpoint) [5CH Operation data]
2D0121	2.A1 (Alarm setpoints for alarm 1) [5CH Operation data]
2D0122	2.A2 (Alarm setpoints for alarm 2) [5CH Operation data]
2D0123	2.PB (Proportional band) [5CH Operation data]
2D0124	2.TI (Integral time) [5CH Operation data]
2D0125	2.TD (Derivative time) [5CH Operation data]
2D0126	2.MR (Manual reset) [5CH Operation data]
2D0127	2.HYS (Hysteresis) [5CH Operation data]
2D0128	2.DR (Direct/reverse action switching) [5CH Operation data]
2D0130	3.SP (Target setpoint) [5CH Operation data]
2D0131	3.A1 (Alarm setpoints for alarm 1) [5CH Operation data]
2D0132	3.A2 (Alarm setpoints for alarm 2) [5CH Operation data]
2D0133	3.PB (Proportional band) [5CH Operation data]
2D0134	3.TI (Integral time) [5CH Operation data]
2D0135	3.TD (Derivative time) [5CH Operation data]
2D0136	3.MR (Manual reset) [5CH Operation data]
2D0137	3.HYS (Hysteresis) [5CH Operation data]
2D0138	3.DR (Direct/reverse action switching) [5CH Operation data]
2D0140	4.SP (Target setpoint) [5CH Operation data]
2D0141	4.A1 (Alarm setpoints for alarm 1) [5CH Operation data]
2D0142	4.A2 (Alarm setpoints for alarm 2) [5CH Operation data]
2D0143	4.PB (Proportional band) [5CH Operation data]
2D0144	4.TI (Integral time) [5CH Operation data]
2D0145	4.TD (Derivative time) [5CH Operation data]
2D0146	4.MR (Manual reset) [5CH Operation data]
2D0147	4.HYS (Hysteresis) [5CH Operation data]
2D0148	4.DR (Direct/reverse action switching) [5CH Operation data]
2D0150	5.SP (Target setpoint) [5CH Operation data]
2D0151	5.A1 (Alarm setpoints for alarm 1) [5CH Operation data]
2D0152	5.A2 (Alarm setpoints for alarm 2) [5CH Operation data]
2D0153	5.PB (Proportional band) [5CH Operation data]
2D0154	5.TI (Integral time) [5CH Operation data]
2D0155	5.TD (Derivative time) [5CH Operation data]
2D0156	5.MR (Manual reset) [5CH Operation data]
2D0157	5.HYS (Hysteresis) [5CH Operation data]
2D0158	5.DR (Direct/reverse action switching) [5CH Operation data]
2D0160	6.SP (Target setpoint) [5CH Operation data]
2D0161	6.A1 (Alarm setpoints for alarm 1) [5CH Operation data]
2D0162	6.A2 (Alarm setpoints for alarm 2) [5CH Operation data]
2D0163	6.PB (Proportional band) [5CH Operation data]
2D0164	6.TI (Integral time) [5CH Operation data]
2D0165	6.TD (Derivative time) [5CH Operation data]
2D0166	6.MR (Manual reset) [5CH Operation data]
2D0167	6.HYS (Hysteresis) [5CH Operation data]
2D0168	6.DR (Direct/reverse action switching) [5CH Operation data]
2D0170	7.SP (Target setpoint) [5CH Operation data]
2D0171	7.A1 (Alarm setpoints for alarm 1) [5CH Operation data]
2D0172	7.A2 (Alarm setpoints for alarm 2) [5CH Operation data]
2D0173	7.PB (Proportional band) [5CH Operation data]
2D0174	7.TI (Integral time) [5CH Operation data]
2D0175	7.TD (Derivative time) [5CH Operation data]
2D0176	7.MR (Manual reset) [5CH Operation data]
2D0177	7.HYS (Hysteresis) [5CH Operation data]
2D0178	7.DR (Direct/reverse action switching) [5CH Operation data]
2D0180	8.SP (Target setpoint) [5CH Operation data]
2D0181	8.A1 (Alarm setpoints for alarm 1) [5CH Operation data]
2D0182	8.A2 (Alarm setpoints for alarm 2) [5CH Operation data]
2D0183	8.PB (Proportional band) [5CH Operation data]
2D0184	8.TI (Integral time) [5CH Operation data]
2D0185	8.TD (Derivative time) [5CH Operation data]
2D0186	8.MR (Manual reset) [5CH Operation data]
2D0187	8.HYS (Hysteresis) [5CH Operation data]
2D0188	8.DR (Direct/reverse action switching) [5CH Operation data]
2D0210	1.SP (Target setpoint) [6CH Operation data]
2D0211	1.A1 (Alarm setpoints for alarm 1) [6CH Operation data]
2D0212	1.A2 (Alarm setpoints for alarm 2) [6CH Operation data]
2D0213	1.PB (Proportional band) [6CH Operation data]
2D0214	1.TI (Integral time) [6CH Operation data]
2D0215	1.TD (Derivative time) [6CH Operation data]
2D0216	1.MR (Manual reset) [6CH Operation data]
2D0217	1.HYS (Hysteresis) [6CH Operation data]
2D0218	1.DR (Direct/reverse action switching) [6CH Operation data]
2D0220	2.SP (Target setpoint) [6CH Operation data]
2D0221	2.A1 (Alarm setpoints for alarm 1) [6CH Operation data]
2D0222	2.A2 (Alarm setpoints for alarm 2) [6CH Operation data]
2D0223	2.PB (Proportional band) [6CH Operation data]
2D0224	2.TI (Integral time) [6CH Operation data]
2D0225	2.TD (Derivative time) [6CH Operation data]
2D0226	2.MR (Manual reset) [6CH Operation data]
2D0227	2.HYS (Hysteresis) [6CH Operation data]
2D0228	2.DR (Direct/reverse action switching) [6CH Operation data]
2D0230	3.SP (Target setpoint) [6CH Operation data]
2D0231	3.A1 (Alarm setpoints for alarm 1) [6CH Operation data]
2D0232	3.A2 (Alarm setpoints for alarm 2) [6CH Operation data]
2D0233	3.PB (Proportional band) [6CH Operation data]
2D0234	3.TI (Integral time) [6CH Operation data]
2D0235	3.TD (Derivative time) [6CH Operation data]
2D0236	3.MR (Manual reset) [6CH Operation data]
2D0237	3.HYS (Hysteresis) [6CH Operation data]
2D0238	3.DR (Direct/reverse action switching) [6CH Operation data]
2D0240	4.SP (Target setpoint) [6CH Operation data]
2D0241	4.A1 (Alarm setpoints for alarm 1) [6CH Operation data]
2D0242	4.A2 (Alarm setpoints for alarm 2) [6CH Operation data]
2D0243	4.PB (Proportional band) [6CH Operation data]
2D0244	4.TI (Integral time) [6CH Operation data]
2D0245	4.TD (Derivative time) [6CH Operation data]
2D0246	4.MR (Manual reset) [6CH Operation data]
2D0247	4.HYS (Hysteresis) [6CH Operation data]
2D0248	4.DR (Direct/reverse action switching) [6CH Operation data]
2D0250	5.SP (Target setpoint) [6CH Operation data]
2D0251	5.A1 (Alarm setpoints for alarm 1) [6CH Operation data]
2D0252	5.A2 (Alarm setpoints for alarm 2) [6CH Operation data]
2D0253	5.PB (Proportional band) [6CH Operation data]
2D0254	5.TI (Integral time) [6CH Operation data]
2D0255	5.TD (Derivative time) [6CH Operation data]
2D0256	5.MR (Manual reset) [6CH Operation data]
2D0257	5.HYS (Hysteresis) [6CH Operation data]
2D0258	5.DR (Direct/reverse action switching) [6CH Operation data]
2D0260	6.SP (Target setpoint) [6CH Operation data]
2D0261	6.A1 (Alarm setpoints for alarm 1) [6CH Operation data]
2D0262	6.A2 (Alarm setpoints for alarm 2) [6CH Operation data]
2D0263	6.PB (Proportional band) [6CH Operation data]
2D0264	6.TI (Integral time) [6CH Operation data]
2D0265	6.TD (Derivative time) [6CH Operation data]
2D0266	6.MR (Manual reset) [6CH Operation data]
2D0267	6.HYS (Hysteresis) [6CH Operation data]
2D0268	6.DR (Direct/reverse action switching) [6CH Operation data]
2D0270	7.SP (Target setpoint) [6CH Operation data]
2D0271	7.A1 (Alarm setpoints for alarm 1) [6CH Operation data]
2D0272	7.A2 (Alarm setpoints for alarm 2) [6CH Operation data]
2D0273	7.PB (Proportional band) [6CH Operation data]
2D0274	7.TI (Integral time) [6CH Operation data]
2D0275	7.TD (Derivative time) [6CH Operation data]
2D0276	7.MR (Manual reset) [6CH Operation data]
2D0277	7.HYS (Hysteresis) [6CH Operation data]
2D0278	7.DR (Direct/reverse action switching) [6CH Operation data]
2D0280	8.SP (Target setpoint) [6CH Operation data]
2D0281	8.A1 (Alarm setpoints for alarm 1) [6CH Operation data]
2D0282	8.A2 (Alarm setpoints for alarm 2) [6CH Operation data]
2D0283	8.PB (Proportional band) [6CH Operation data]
2D0284	8.TI (Integral time) [6CH Operation data]
2D0285	8.TD (Derivative time) [6CH Operation data]
2D0286	8.MR (Manual reset) [6CH Operation data]
2D0287	8.HYS (Hysteresis) [6CH Operation data]
2D0288	8.DR (Direct/reverse action switching) [6CH Operation data]
2D0310	1.SP (Target setpoint) [7CH Operation data]
2D0311	1.A1 (Alarm setpoints for alarm 1) [7CH Operation data]
2D0312	1.A2 (Alarm setpoints for alarm 2) [7CH Operation data]
2D0313	1.PB (Proportional band) [7CH Operation data]
2D0314	1.TI (Integral time) [7CH Operation data]
2D0315	1.TD (Derivative time) [7CH Operation data]
2D0316	1.MR (Manual reset) [7CH Operation data]
2D0317	1.HYS (Hysteresis) [7CH Operation data]
2D0318	1.DR (Direct/reverse action switching) [7CH Operation data]
2D0320	2.SP (Target setpoint) [7CH Operation data]
2D0321	2.A1 (Alarm setpoints for alarm 1) [7CH Operation data]
2D0322	2.A2 (Alarm setpoints for alarm 2) [7CH Operation data]
2D0323	2.PB (Proportional band) [7CH Operation data]
2D0324	2.TI (Integral time) [7CH Operation data]
2D0325	2.TD (Derivative time) [7CH Operation data]
2D0326	2.MR (Manual reset) [7CH Operation data]
2D0327	2.HYS (Hysteresis) [7CH Operation data]
2D0328	2.DR (Direct/reverse action switching) [7CH Operation data]
2D0330	3.SP (Target setpoint) [7CH Operation data]
2D0331	3.A1 (Alarm setpoints for alarm 1) [7CH Operation data]
2D0332	3.A2 (Alarm setpoints for alarm 2) [7CH Operation data]
2D0333	3.PB (Proportional band) [7CH Operation data]
2D0334	3.TI (Integral time) [7CH Operation data]
2D0335	3.TD (Derivative time) [7CH Operation data]
2D0336	3.MR (Manual reset) [7CH Operation data]
2D0337	3.HYS (Hysteresis) [7CH Operation data]
2D0338	3.DR (Direct/reverse action switching) [7CH Operation data]
2D0340	4.SP (Target setpoint) [7CH Operation data]
2D0341	4.A1 (Alarm setpoints for alarm 1) [7CH Operation data]
2D0342	4.A2 (Alarm setpoints for alarm 2) [7CH Operation data]
2D0343	4.PB (Proportional band) [7CH Operation data]
2D0344	4.TI (Integral time) [7CH Operation data]
2D0345	4.TD (Derivative time) [7CH Operation data]
2D0346	4.MR (Manual reset) [7CH Operation data]
2D0347	4.HYS (Hysteresis) [7CH Operation data]
2D0348	4.DR (Direct/reverse action switching) [7CH Operation data]
2D0350	5.SP (Target setpoint) [7CH Operation data]
2D0351	5.A1 (Alarm setpoints for alarm 1) [7CH Operation data]
2D0352	5.A2 (Alarm setpoints for alarm 2) [7CH Operation data]
2D0353	5.PB (Proportional band) [7CH Operation data]
2D0354	5.TI (Integral time) [7CH Operation data]
2D0355	5.TD (Derivative time) [7CH Operation data]
2D0356	5.MR (Manual reset) [7CH Operation data]
2D0357	5.HYS (Hysteresis) [7CH Operation data]
2D0358	5.DR (Direct/reverse action switching) [7CH Operation data]
2D0360	6.SP (Target setpoint) [7CH Operation data]
2D0361	6.A1 (Alarm setpoints for alarm 1) [7CH Operation data]
2D0362	6.A2 (Alarm setpoints for alarm 2) [7CH Operation data]
2D0363	6.PB (Proportional band) [7CH Operation data]
2D0364	6.TI (Integral time) [7CH Operation data]
2D0365	6.TD (Derivative time) [7CH Operation data]
2D0366	6.MR (Manual reset) [7CH Operation data]
2D0367	6.HYS (Hysteresis) [7CH Operation data]
2D0368	6.DR (Direct/reverse action switching) [7CH Operation data]
2D0370	7.SP (Target setpoint) [7CH Operation data]
2D0371	7.A1 (Alarm setpoints for alarm 1) [7CH Operation data]
2D0372	7.A2 (Alarm setpoints for alarm 2) [7CH Operation data]
2D0373	7.PB (Proportional band) [7CH Operation data]
2D0374	7.TI (Integral time) [7CH Operation data]
2D0375	7.TD (Derivative time) [7CH Operation data]
2D0376	7.MR (Manual reset) [7CH Operation data]
2D0377	7.HYS (Hysteresis) [7CH Operation data]
2D0378	7.DR (Direct/reverse action switching) [7CH Operation data]
2D0380	8.SP (Target setpoint) [7CH Operation data]
2D0381	8.A1 (Alarm setpoints for alarm 1) [7CH Operation data]
2D0382	8.A2 (Alarm setpoints for alarm 2) [7CH Operation data]
2D0383	8.PB (Proportional band) [7CH Operation data]
2D0384	8.TI (Integral time) [7CH Operation data]
2D0385	8.TD (Derivative time) [7CH Operation data]
2D0386	8.MR (Manual reset) [7CH Operation data]
2D0387	8.HYS (Hysteresis) [7CH Operation data]
2D0388	8.DR (Direct/reverse action switching) [7CH Operation data]
2D0410	1.SP (Target setpoint) [8CH Operation data]
2D0411	1.A1 (Alarm setpoints for alarm 1) [8CH Operation data]
2D0412	1.A2 (Alarm setpoints for alarm 2) [8CH Operation data]
2D0413	1.PB (Proportional band) [8CH Operation data]
2D0414	1.TI (Integral time) [8CH Operation data]
2D0415	1.TD (Derivative time) [8CH Operation data]
2D0416	1.MR (Manual reset) [8CH Operation data]
2D0417	1.HYS (Hysteresis) [8CH Operation data]
2D0418	1.DR (Direct/reverse action switching) [8CH Operation data]
2D0420	2.SP (Target setpoint) [8CH Operation data]
2D0421	2.A1 (Alarm setpoints for alarm 1) [8CH Operation data]
2D0422	2.A2 (Alarm setpoints for alarm 2) [8CH Operation data]
2D0423	2.PB (Proportional band) [8CH Operation data]
2D0424	2.TI (Integral time) [8CH Operation data]
2D0425	2.TD (Derivative time) [8CH Operation data]
2D0426	2.MR (Manual reset) [8CH Operation data]
2D0427	2.HYS (Hysteresis) [8CH Operation data]
2D0428	2.DR (Direct/reverse action switching) [8CH Operation data]
2D0430	3.SP (Target setpoint) [8CH Operation data]
2D0431	3.A1 (Alarm setpoints for alarm 1) [8CH Operation data]
2D0432	3.A2 (Alarm setpoints for alarm 2) [8CH Operation data]
2D0433	3.PB (Proportional band) [8CH Operation data]
2D0434	3.TI (Integral time) [8CH Operation data]
2D0435	3.TD (Derivative time) [8CH Operation data]
2D0436	3.MR (Manual reset) [8CH Operation data]
2D0437	3.HYS (Hysteresis) [8CH Operation data]
2D0438	3.DR (Direct/reverse action switching) [8CH Operation data]
2D0440	4.SP (Target setpoint) [8CH Operation data]
2D0441	4.A1 (Alarm setpoints for alarm 1) [8CH Operation data]
2D0442	4.A2 (Alarm setpoints for alarm 2) [8CH Operation data]
2D0443	4.PB (Proportional band) [8CH Operation data]
2D0444	4.TI (Integral time) [8CH Operation data]
2D0445	4.TD (Derivative time) [8CH Operation data]
2D0446	4.MR (Manual reset) [8CH Operation data]
2D0447	4.HYS (Hysteresis) [8CH Operation data]
2D0448	4.DR (Direct/reverse action switching) [8CH Operation data]
2D0450	5.SP (Target setpoint) [8CH Operation data]
2D0451	5.A1 (Alarm setpoints for alarm 1) [8CH Operation data]
2D0452	5.A2 (Alarm setpoints for alarm 2) [8CH Operation data]
2D0453	5.PB (Proportional band) [8CH Operation data]
2D0454	5.TI (Integral time) [8CH Operation data]
2D0455	5.TD (Derivative time) [8CH Operation data]
2D0456	5.MR (Manual reset) [8CH Operation data]
2D0457	5.HYS (Hysteresis) [8CH Operation data]
2D0458	5.DR (Direct/reverse action switching) [8CH Operation data]
2D0460	6.SP (Target setpoint) [8CH Operation data]
2D0461	6.A1 (Alarm setpoints for alarm 1) [8CH Operation data]
2D0462	6.A2 (Alarm setpoints for alarm 2) [8CH Operation data]
2D0463	6.PB (Proportional band) [8CH Operation data]
2D0464	6.TI (Integral time) [8CH Operation data]
2D0465	6.TD (Derivative time) [8CH Operation data]
2D0466	6.MR (Manual reset) [8CH Operation data]
2D0467	6.HYS (Hysteresis) [8CH Operation data]
2D0468	6.DR (Direct/reverse action switching) [8CH Operation data]
2D0470	7.SP (Target setpoint) [8CH Operation data]
2D0471	7.A1 (Alarm setpoints for alarm 1) [8CH Operation data]
2D0472	7.A2 (Alarm setpoints for alarm 2) [8CH Operation data]
2D0473	7.PB (Proportional band) [8CH Operation data]
2D0474	7.TI (Integral time) [8CH Operation data]
2D0475	7.TD (Derivative time) [8CH Operation data]
2D0476	7.MR (Manual reset) [8CH Operation data]
2D0477	7.HYS (Hysteresis) [8CH Operation data]
2D0478	7.DR (Direct/reverse action switching) [8CH Operation data]
2D0480	8.SP (Target setpoint) [8CH Operation data]
2D0481	8.A1 (Alarm setpoints for alarm 1) [8CH Operation data]
2D0482	8.A2 (Alarm setpoints for alarm 2) [8CH Operation data]
2D0483	8.PB (Proportional band) [8CH Operation data]
2D0484	8.TI (Integral time) [8CH Operation data]
2D0485	8.TD (Derivative time) [8CH Operation data]
2D0486	8.MR (Manual reset) [8CH Operation data]
2D0487	8.HYS (Hysteresis) [8CH Operation data]
2D0488	8.DR (Direct/reverse action switching) [8CH Operation data]
2D0510	1.SP (Target setpoint) [All CH5~CH8 setting]
2D0511	1.A1 (Alarm setpoints for alarm 1) [All CH5~CH8 setting]
2D0512	1.A2 (Alarm setpoints for alarm 2) [All CH5~CH8 setting]
2D0513	1.PB (Proportional band) [All CH5~CH8 setting]
2D0514	1.TI (Integral time) [All CH5~CH8 setting]
2D0515	1.TD (Derivative time) [All CH5~CH8 setting]
2D0516	1.MR (Manual reset) [All CH5~CH8 setting]
2D0517	1.HYS (Hysteresis) [All CH5~CH8 setting]
2D0518	1.DR (Direct/reverse action switching) [All CH5~CH8 setting]
2D0520	2.SP (Target setpoint) [All CH5~CH8 setting]
2D0521	2.A1 (Alarm setpoints for alarm 1) [All CH5~CH8 setting]
2D0522	2.A2 (Alarm setpoints for alarm 2) [All CH5~CH8 setting]
2D0523	2.PB (Proportional band) [All CH5~CH8 setting]
2D0524	2.TI (Integral time) [All CH5~CH8 setting]
2D0525	2.TD (Derivative time) [All CH5~CH8 setting]
2D0526	2.MR (Manual reset) [All CH5~CH8 setting]
2D0527	2.HYS (Hysteresis) [All CH5~CH8 setting]
2D0528	2.DR (Direct/reverse action switching) [All CH5~CH8 setting]
2D0530	3.SP (Target setpoint) [All CH5~CH8 setting]
2D0531	3.A1 (Alarm setpoints for alarm 1) [All CH5~CH8 setting]
2D0532	3.A2 (Alarm setpoints for alarm 2) [All CH5~CH8 setting]
2D0533	3.PB (Proportional band) [All CH5~CH8 setting]
2D0534	3.TI (Integral time) [All CH5~CH8 setting]
2D0535	3.TD (Derivative time) [All CH5~CH8 setting]
2D0536	3.MR (Manual reset) [All CH5~CH8 setting]
2D0537	3.HYS (Hysteresis) [All CH5~CH8 setting]
2D0538	3.DR (Direct/reverse action switching) [All CH5~CH8 setting]
2D0540	4.SP (Target setpoint) [All CH5~CH8 setting]
2D0541	4.A1 (Alarm setpoints for alarm 1) [All CH5~CH8 setting]
2D0542	4.A2 (Alarm setpoints for alarm 2) [All CH5~CH8 setting]
2D0543	4.PB (Proportional band) [All CH5~CH8 setting]
2D0544	4.TI (Integral time) [All CH5~CH8 setting]
2D0545	4.TD (Derivative time) [All CH5~CH8 setting]
2D0546	4.MR (Manual reset) [All CH5~CH8 setting]
2D0547	4.HYS (Hysteresis) [All CH5~CH8 setting]
2D0548	4.DR (Direct/reverse action switching) [All CH5~CH8 setting]
2D0550	5.SP (Target setpoint) [All CH5~CH8 setting]
2D0551	5.A1 (Alarm setpoints for alarm 1) [All CH5~CH8 setting]
2D0552	5.A2 (Alarm setpoints for alarm 2) [All CH5~CH8 setting]
2D0553	5.PB (Proportional band) [All CH5~CH8 setting]
2D0554	5.TI (Integral time) [All CH5~CH8 setting]
2D0555	5.TD (Derivative time) [All CH5~CH8 setting]
2D0556	5.MR (Manual reset) [All CH5~CH8 setting]
2D0557	5.HYS (Hysteresis) [All CH5~CH8 setting]
2D0558	5.DR (Direct/reverse action switching) [All CH5~CH8 setting]
2D0560	6.SP (Target setpoint) [All CH5~CH8 setting]
2D0561	6.A1 (Alarm setpoints for alarm 1) [All CH5~CH8 setting]
2D0562	6.A2 (Alarm setpoints for alarm 2) [All CH5~CH8 setting]
2D0563	6.PB (Proportional band) [All CH5~CH8 setting]
2D0564	6.TI (Integral time) [All CH5~CH8 setting]
2D0565	6.TD (Derivative time) [All CH5~CH8 setting]
2D0566	6.MR (Manual reset) [All CH5~CH8 setting]
2D0567	6.HYS (Hysteresis) [All CH5~CH8 setting]
2D0568	6.DR (Direct/reverse action switching) [All CH5~CH8 setting]
2D0570	7.SP (Target setpoint) [All CH5~CH8 setting]
2D0571	7.A1 (Alarm setpoints for alarm 1) [All CH5~CH8 setting]
2D0572	7.A2 (Alarm setpoints for alarm 2) [All CH5~CH8 setting]
2D0573	7.PB (Proportional band) [All CH5~CH8 setting]
2D0574	7.TI (Integral time) [All CH5~CH8 setting]
2D0575	7.TD (Derivative time) [All CH5~CH8 setting]
2D0576	7.MR (Manual reset) [All CH5~CH8 setting]
2D0577	7.HYS (Hysteresis) [All CH5~CH8 setting]
2D0578	7.DR (Direct/reverse action switching) [All CH5~CH8 setting]
2D0580	8.SP (Target setpoint) [All CH5~CH8 setting]
2D0581	8.A1 (Alarm setpoints for alarm 1) [All CH5~CH8 setting]
2D0582	8.A2 (Alarm setpoints for alarm 2) [All CH5~CH8 setting]
2D0583	8.PB (Proportional band) [All CH5~CH8 setting]
2D0584	8.TI (Integral time) [All CH5~CH8 setting]
2D0585	8.TD (Derivative time) [All CH5~CH8 setting]
2D0586	8.MR (Manual reset) [All CH5~CH8 setting]
2D0587	8.HYS (Hysteresis) [All CH5~CH8 setting]
2D0588	8.DR (Direct/reverse action switching) [All CH5~CH8 setting]
2D0600	SC (SUPER function selection) [5CH Setup data]
2D0601	AT (Auto-tuning selection) [5CH Setup data]
2D0602	SP.UP (Setpoint ramp-up rate setting) [5CH Setup data]
2D0603	SP.DN (Setpoint ramp-down rate setting) [5CH Setup data]
2D0604	SP.R (Ramp-rate time unit setting) [5CH Setup data]
2D0605	FL (Filter) [5CH Setup data]
2D0606	BS (Input compensation bias) [5CH Setup data]
2D0607	A/M (AUTO/MAN modes) [5CH Setup data]
2D0608	R/S (STOP/RUN modes) [5CH Setup data]
2D0609	MANOUT (Manual output value) [5CH Setup data]
2D0610	PROUT (Preset output value) [5CH Setup data]
2D0611	SPNO (Group SP number) [5CH Setup data]
2D0612	HB (Heater current measurement) [5CH Setup data]
2D0613	AL1 (Alarm-1 type) [5CH Setup data]
2D0614	AL2 (Alarm-2 type) [5CH Setup data]
2D0615	HY1 (Alarm-1 hysteresis) [5CH Setup data]
2D0616	HY2 (Alarm-2 hysteresis) [5CH Setup data]
2D0617	CT (Cycle time) [5CH Setup data]
2D0618	OH (Upper limit of output) [5CH Setup data]
2D0619	OL (Lower limit of output) [5CH Setup data]
2D0620	RST (Restart mode) [5CH Setup data]
2D0621	ORBND (ON/OFF rate detection width) [5CH Setup data]
2D0622	ORHI (ON/OFF rate upper limit) [5CH Setup data]
2D0623	ORLO (ON/OFF rate lower limit) [5CH Setup data]
2D0624	USE (use/unuse) [5CH Setup data]
2D0625	A3 (Alarm-3 setpoint) [5CH Setup data]
2D0626	AL3 (Alarm-3 type) [5CH Setup data]
2D0627	HY3 (Alarm-3 hysteresis) [5CH Setup data]
2D0650	PD (Decimal point position) [5CH Setup data]
2D0651	RH (Instrument range upper limit) [5CH Setup data]
2D0652	RL (Instrument range lower limit) [5CH Setup data]
2D0653	ARSL (ARM action mode) [5CH Setup data]
2D0654	MD (Channel action mode) [5CH Setup data]
2D0700	SC (SUPER function selection) [6CH Setup data]
2D0701	AT (Auto-tuning selection) [6CH Setup data]
2D0702	SP.UP (Setpoint ramp-up rate setting) [6CH Setup data]
2D0703	SP.DN (Setpoint ramp-down rate setting) [6CH Setup data]
2D0704	SP.R (Rate time unit) [6CH Setup data]
2D0705	FL (Filter) [6CH Setup data]
2D0706	BS (Input compensation bias) [6CH Setup data]
2D0707	A/M (AUTO/MAN modes) [6CH Setup data]
2D0708	R/S (STOP/RUN modes) [6CH Setup data]
2D0709	MANOUT (ManualOutput value) [6CH Setup data]
2D0710	PROUT (PresetOutput value) [6CH Setup data]
2D0711	SPNO (Group SP number) [6CH Setup data]
2D0712	HB (Heater current measurement) [6CH Setup data]
2D0713	AL1 (Alarm-1 type) [6CH Setup data]
2D0714	AL2 (Alarm-2 type) [6CH Setup data]
2D0715	HY1 (Alarm-1 hysteresis) [6CH Setup data]
2D0716	HY2 (Alarm-2 hysteresis) [6CH Setup data]
2D0717	CT (Cycle time) [6CH Setup data]
2D0718	OH (Upper limit of output) [6CH Setup data]
2D0719	OL (Lower limit of output) [6CH Setup data]
2D0720	RST (Restart mode) [6CH Setup data]
2D0721	ORBND (ON/OFF rate detection width) [6CH Setup data]
2D0722	ORHI (ON/OFF rate upper limit) [6CH Setup data]
2D0723	ORLO (ON/OFF rate lower limit) [6CH Setup data]
2D0724	USE (use/unuse) [6CH Setup data]
2D0725	A3 (Alarm-3 setpoint) [6CH Setup data]
2D0726	AL3 (Alarm-3 type) [6CH Setup data]
2D0727	HY3 (Alarm-3 hysteresis) [6CH Setup data]
2D0750	PD (Decimal point position) [6CH Setup data]
2D0751	RH (Instrument range upper limit) [6CH Setup data]
2D0752	RL (Instrument range lower limit) [6CH Setup data]
2D0753	ARSL (ARM action mode) [6CH Setup data]
2D0754	MD (Channel action mode) [6CH Setup data]
2D0800	SC (SUPER function selection) [7CH Setup data]
2D0801	AT (Auto-tuning selection) [7CH Setup data]
2D0802	SP.UP (Setpoint ramp-up rate setting) [7CH Setup data]
2D0803	SP.DN (Setpoint ramp-down rate setting) [7CH Setup data]
2D0804	SP.R (Rate time unit) [7CH Setup data]
2D0805	FL (Filter) [7CH Setup data]
2D0806	BS (Input compensation bias) [7CH Setup data]
2D0807	A/M (AUTO/MAN modes) [7CH Setup data]
2D0808	R/S (STOP/RUN modes) [7CH Setup data]
2D0809	MANOUT (ManualOutput value) [7CH Setup data]
2D0810	PROUT (PresetOutput value) [7CH Setup data]
2D0811	SPNO (Group SP number) [7CH Setup data]
2D0812	HB (Heater current measurement) [7CH Setup data]
2D0813	AL1 (Alarm-1 type) [7CH Setup data]
2D0814	AL2 (Alarm-2 type) [7CH Setup data]
2D0815	HY1 (Alarm-1 hysteresis) [7CH Setup data]
2D0816	HY2 (Alarm-2 hysteresis) [7CH Setup data]
2D0817	CT (Cycle time) [7CH Setup data]
2D0818	OH (Upper limit of output) [7CH Setup data]
2D0819	OL (Lower limit of output) [7CH Setup data]
2D0820	RST (Restart mode) [7CH Setup data]
2D0821	ORBND (ON/OFF rate detection width) [7CH Setup data]
2D0822	ORHI (ON/OFF rate upper limit) [7CH Setup data]
2D0823	ORLO (ON/OFF rate lower limit) [7CH Setup data]
2D0824	USE (use/unuse) [7CH Setup data]
2D0825	A3 (Alarm-3 setpoint) [7CH Setup data]
2D0826	AL3 (Alarm-3 type) [7CH Setup data]
2D0827	HY3 (Alarm-3 hysteresis) [7CH Setup data]
2D0850	PD (Decimal point position) [7CH Setup data]
2D0851	RH (Instrument range upper limit) [7CH Setup data]
2D0852	RL (Instrument range lower limit) [7CH Setup data]
2D0853	ARSL (ARM action mode) [7CH Setup data]
2D0854	MD (Channel action mode) [7CH Setup data]
2D0900	SC (SUPER function selection) [8CH Setup data]
2D0901	AT (Auto-tuning selection) [8CH Setup data]
2D0902	SP.UP (Setpoint ramp-up rate setting) [8CH Setup data]
2D0903	SP.DN (Setpoint ramp-down rate setting) [8CH Setup data]
2D0904	SP.R (Rate time unit) [8CH Setup data]
2D0905	FL (Filter) [8CH Setup data]
2D0906	BS (Input compensation bias) [8CH Setup data]
2D0907	A/M (AUTO/MAN modes) [8CH Setup data]
2D0908	R/S (STOP/RUN modes) [8CH Setup data]
2D0909	MANOUT (Manual output value) [8CH Setup data]
2D0910	PROUT (Preset output value) [8CH Setup data]
2D0911	SPNO (Group SP number) [8CH Setup data]
2D0912	HB (Heater current measurement) [8CH Setup data]
2D0913	AL1 (Alarm-1 type) [8CH Setup data]
2D0914	AL2 (Alarm-2 type) [8CH Setup data]
2D0915	HY1 (Alarm-1 hysteresis) [8CH Setup data]
2D0916	HY2 (Alarm-2 hysteresis) [8CH Setup data]
2D0917	CT (Cycle time) [8CH Setup data]
2D0918	OH (Upper limit of output) [8CH Setup data]
2D0919	OL (Lower limit of output) [8CH Setup data]
2D0920	RST (Restart mode) [8CH Setup data]
2D0921	ORBND (ON/OFF rate detection width) [8CH Setup data]
2D0922	ORHI (ON/OFF rate upper limit) [8CH Setup data]
2D0923	ORLO (ON/OFF rate lower limit) [8CH Setup data]
2D0924	USE (use/unuse) [8CH Setup data]
2D0925	A3 (Alarm-3 setpoint) [8CH Setup data]
2D0926	AL3 (Alarm-3 type) [8CH Setup data]
2D0927	HY3 (Alarm-3 hysteresis) [8CH Setup data]
2D0950	PD (Decimal point position) [8CH Setup data]
2D0951	RH (Instrument range upper limit) [8CH Setup data]
2D0952	RL (Instrument range lower limit) [8CH Setup data]
2D0953	ARSL (ARM action mode) [8CH Setup data]
2D0954	MD (Channel action mode) [8CH Setup data]
2D0955	STEUP (Setup mode) [All CH Setup data]
2D0956	IN (Input type) [All CH Setup data]
2D1000	SC (SUPER function selection) [All CH5~CH8 setting]
2D1001	AT (Auto-tuning selection) [All CH5~CH8 setting]
2D1002	SP.UP (Setpoint ramp-up rate setting) [All CH5~CH8 setting]
2D1003	SP.DN (Setpoint ramp-down rate setting) [All CH5~CH8 setting]
2D1004	SP.R (Rate time unit) [All CH5~CH8 setting]
2D1005	FL (Filter) [All CH5~CH8 setting]
2D1006	BS (Input compensation bias) [All CH5~CH8 setting]
2D1007	A/M (AUTO/MAN modes) [All CH5~CH8 setting]
2D1008	R/S (STOP/RUN modes) [All CH5~CH8 setting]
2D1009	MANOUT (ManualOutput value) [All CH5~CH8 setting]
2D1010	PROUT (PresetOutput value) [All CH5~CH8 setting]
2D1011	SPNO (Group SP number) [All CH5~CH8 setting]
2D1012	HB (Heater current measurement) [All CH5~CH8 setting]
2D1013	AL1 (Alarm-1 type) [All CH5~CH8 setting]
2D1014	AL2 (Alarm-2 type) [All CH5~CH8 setting]
2D1015	HY1 (Alarm-1 hysteresis) [All CH5~CH8 setting]
2D1016	HY2 (Alarm-2 hysteresis) [All CH5~CH8 setting]
2D1017	CT (Cycle time) [All CH5~CH8 setting]
2D1018	OH (Upper limit of output) [All CH5~CH8 setting]
2D1019	OL (Lower limit of output) [All CH5~CH8 setting]
2D1020	RST (Restart mode) [All CH5~CH8 setting]
2D1021	ORBND (ON/OFF rate detection width) [All CH5~CH8 setting]
2D1022	ORHI (ON/OFF rate upper limit) [All CH5~CH8 setting]
2D1023	ORLO (ON/OFF rate lower limit) [All CH5~CH8 setting]
2D1024	USE (use/unuse) [All CH5~CH8 setting]
[D-SigDataEnd-2]

[D-SigData]-B
1D0001.00    AL1 relay
1D0001.04    AL2 relay
1D0001.08    HB relay
1D0001.12    ALM lamp
1D0001.13    ERR lamp
1D0002.00    AL1 [CH1]
1D0002.01    AL2 [CH1]
1D0002.02    HB(AL3) [CH1]
1D0002.04    Burnout [CH1]
1D0002.05    +Over [CH1]
1D0002.06    -Over [CH1]
1D0002.08    ADC error [CH1]
1D0002.09    RJC error [CH1]
1D0002.10    Heater Shield [CH1]
1D0002.12    System data error [CH1]
1D0002.13    Calibration value error [CH1]
1D0002.14    Parameter erroe [CH1]
1D0003.00    AL1 [CH2]
1D0003.01    AL2 [CH2]
1D0003.02    HB(AL3) [CH2]
1D0003.04    Burnout [CH2]
1D0003.05    +Over [CH2]
1D0003.06    -Over [CH2]
1D0003.08    ADC error [CH2]
1D0003.09    RJC error [CH2]
1D0003.10    Heater Shield [CH2]
1D0003.12    System data error [CH2]
1D0003.13    Calibration value error [CH2]
1D0003.14    Parameter error [CH2]
1D0004.00    AL1 [CH3]
1D0004.01    AL2 [CH3]
1D0004.02    HB(AL3) [CH3]
1D0004.04    Burnout [CH3]
1D0004.05    +Over [CH3]
1D0004.06    -Over [CH3]
1D0004.08    ADC error [CH3]
1D0004.09    RJC error [CH3]
1D0004.10    Heater Shield [CH3]
1D0004.12    System data error [CH3]
1D0004.13    Calibration value error [CH3]
1D0004.14    Parameter error [CH3]
1D0005.00    AL1 [CH4]
1D0005.01    AL2 [CH4]
1D0005.02    HB(AL3) [CH4]
1D0005.04    Burnout [CH4]
1D0005.05    +Over [CH4]
1D0005.06    -Over [CH4]
1D0005.08    ADC error [CH4]
1D0005.09    RJC error [CH4]
1D0005.10    Heater Shield [CH4]
1D0005.12    System data error [CH4]
1D0005.13    Calibration value error [CH4]
1D0005.14    Parameter error [CH4]
1D0006	      1.PV (Process value) [CH1]
1D0007	      2.PV (Process value) [CH2]
1D0008	      3.PV (Process value) [CH3]
1D0009	      4.PV (Process value) [CH4]
1D0010	      1.CSP (Current target setpoint) [CH1]
1D0011	      2.CSP (Current target setpoint) [CH2]
1D0012	      3.CSP (Current target setpoint) [CH3]
1D0013	      4.CSP (Current target setpoint) [CH4]
1D0014	      1.OUT (Output value) [CH1]
1D0015	      2.OUT (Output value) [CH2]
1D0016	      3.OUT (Output value) [CH3]
1D0017	      4.OUT (Output value) [CH4]
1D0018.00    0:AUTO 1:MAN [CH1]
1D0018.04    0:RUN 1:STOP[CH1]
1D0018.12    0:Auto-tuning OFF 1:Auto-tuning ON [CH1]
1D0019.00    0:AUTO 1:MAN [CH2]
1D0019.04    0:RUN 1:STOP[CH2]
1D0019.12    0:Auto-tuning OFF 1:Auto-tuning ON [CH2]
1D0020.00    0:AUTO 1:MAN [CH3]
1D0020.04    0:RUN 1:STOP[CH3]
1D0020.12    0:Auto-tuning OFF 1:Auto-tuning ON [CH3]
1D0021.00    0:AUTO 1:MAN [CH4]
1D0021.04    0:RUN 1:STOP[CH4]
1D0021.12    0:Auto-tuning OFF 1:Auto-tuning ON [CH4]
1D0022	      1.DEV (Deviation) [CH1]
1D0023	      2.DEV (Deviation) [CH2]
1D0024	      3.DEV (Deviation) [CH3]
1D0025	      4.DEV (Deviation) [CH4]
1D0026	      1.SPNO (Set group number) [CH1]
1D0027	      2.SPNO (Set group number) [CH2]
1D0028	      3.SPNO (Set group number) [CH3]
1D0029	      4.SPNO (Set group number) [CH4]
1D0030	      1.HC (Heater current value) [CH1]
1D0031	      2.HC (Heater current value) [CH2]
1D0032	      3.HC (Heater current value) [CH3]
1D0033	      4.HC (Heater current value) [CH4]
1D0090	      (REG SL)
1D0091	      (100%)
1D0092	      (75%)
1D0093	      (50%)
1D0094	      (25%)
1D0095	      (0%)
1D0110	      1.SP (Target setpoint) [1CH Operation data]
1D0111	      1.A1 (Alarm setpoints for alarm 1) [1CH Operation data]
1D0112	      1.A2 (Alarm setpoints for alarm 2) [1CH Operation data]
1D0113	      1.PB (Proportional band) [1CH Operation data]
1D0114	      1.TI (Integral time) [1CH Operation data]
1D0115	      1.TD (Derivative time) [1CH Operation data]
1D0116	      1.MR (Manual reset) [1CH Operation data]
1D0117	      1.HYS (Hysteresis) [1CH Operation data]
1D0118	      1.DR (Direct/reverse action switching) [1CH Operation data]
1D0120	      2.SP (Target setpoint) [1CH Operation data]
1D0121	      2.A1 (Alarm setpoints for alarm 1) [1CH Operation data]
1D0122	      2.A2 (Alarm setpoints for alarm 2) [1CH Operation data]
1D0123	      2.PB (Proportional band) [1CH Operation data]
1D0124	      2.TI (Integral time) [1CH Operation data]
1D0125	      2.TD (Derivative time) [1CH Operation data]
1D0126	      2.MR (Manual reset) [1CH Operation data]
1D0127	      2.HYS (Hysteresis) [1CH Operation data]
1D0128	      2.DR (Direct/reverse action switching) [1CH Operation data]
1D0130	      3.SP (Target setpoint) [1CH Operation data]
1D0131	      3.A1 (Alarm setpoints for alarm 1) [1CH Operation data]
1D0132	      3.A2 (Alarm setpoints for alarm 2) [1CH Operation data]
1D0133	      3.PB (Proportional band) [1CH Operation data]
1D0134	      3.TI (Integral time) [1CH Operation data]
1D0135	      3.TD (Derivative time) [1CH Operation data]
1D0136	      3.MR (Manual reset) [1CH Operation data]
1D0137	      3.HYS (Hysteresis) [1CH Operation data]
1D0138	      3.DR (Direct/reverse action switching) [1CH Operation data]
1D0140	      4.SP (Target setpoint) [1CH Operation data]
1D0141	      4.A1 (Alarm setpoints for alarm 1) [1CH Operation data]
1D0142	      4.A2 (Alarm setpoints for alarm 2) [1CH Operation data]
1D0143	      4.PB (Proportional band) [1CH Operation data]
1D0144	      4.TI (Integral time) [1CH Operation data]
1D0145	      4.TD (Derivative time) [1CH Operation data]
1D0146	      4.MR (Manual reset) [1CH Operation data]
1D0147	      4.HYS (Hysteresis) [1CH Operation data]
1D0148	      4.DR (Direct/reverse action switching) [1CH Operation data]
1D0150	      5.SP (Target setpoint) [1CH Operation data]
1D0151	      5.A1 (Alarm setpoints for alarm 1) [1CH Operation data]
1D0152	      5.A2 (Alarm setpoints for alarm 2) [1CH Operation data]
1D0153	      5.PB (Proportional band) [1CH Operation data]
1D0154	      5.TI (Integral time) [1CH Operation data]
1D0155	      5.TD (Derivative time) [1CH Operation data]
1D0156	      5.MR (Manual reset) [1CH Operation data]
1D0157	      5.HYS (Hysteresis) [1CH Operation data]
1D0158	      5.DR (Direct/reverse action switching) [1CH Operation data]
1D0160	      6.SP (Target setpoint) [1CH Operation data]
1D0161	      6.A1 (Alarm setpoints for alarm 1) [1CH Operation data]
1D0162	      6.A2 (Alarm setpoints for alarm 2) [1CH Operation data]
1D0163	      6.PB (Proportional band) [1CH Operation data]
1D0164	      6.TI (Integral time) [1CH Operation data]
1D0165	      6.TD (Derivative time) [1CH Operation data]
1D0166	      6.MR (Manual reset) [1CH Operation data]
1D0167	      6.HYS (Hysteresis) [1CH Operation data]
1D0168	      6.DR (Direct/reverse action switching) [1CH Operation data]
1D0170	      7.SP (Target setpoint) [1CH Operation data]
1D0171	      7.A1 (Alarm setpoints for alarm 1) [1CH Operation data]
1D0172	      7.A2 (Alarm setpoints for alarm 2) [1CH Operation data]
1D0173	      7.PB (Proportional band) [1CH Operation data]
1D0174	      7.TI (Integral time) [1CH Operation data]
1D0175	      7.TD (Derivative time) [1CH Operation data]
1D0176	      7.MR (Manual reset) [1CH Operation data]
1D0177	      7.HYS (Hysteresis) [1CH Operation data]
1D0178	      7.DR (Direct/reverse action switching) [1CH Operation data]
1D0180	      8.SP (Target setpoint) [1CH Operation data]
1D0181	      8.A1 (Alarm setpoints for alarm 1) [1CH Operation data]
1D0182	      8.A2 (Alarm setpoints for alarm 2) [1CH Operation data]
1D0183	      8.PB (Proportional band) [1CH Operation data]
1D0184	      8.TI (Integral time) [1CH Operation data]
1D0185	      8.TD (Derivative time) [1CH Operation data]
1D0186	      8.MR (Manual reset) [1CH Operation data]
1D0187	      8.HYS (Hysteresis) [1CH Operation data]
1D0188	      8.DR (Direct/reverse action switching) [1CH Operation data]
1D0210	      1.SP (Target setpoint) [2CH Operation data]
1D0211	      1.A1 (Alarm setpoints for alarm 1) [2CH Operation data]
1D0212	      1.A2 (Alarm setpoints for alarm 2) [2CH Operation data]
1D0213	      1.PB (Proportional band) [2CH Operation data]
1D0214	      1.TI (Integral time) [2CH Operation data]
1D0215	      1.TD (Derivative time) [2CH Operation data]
1D0216	      1.MR (Manual reset) [2CH Operation data]
1D0217	      1.HYS (Hysteresis) [2CH Operation data]
1D0218	      1.DR (Direct/reverse action switching) [2CH Operation data]
1D0220	      2.SP (Target setpoint) [2CH Operation data]
1D0221	      2.A1 (Alarm setpoints for alarm 1) [2CH Operation data]
1D0222	      2.A2 (Alarm setpoints for alarm 2) [2CH Operation data]
1D0223	      2.PB (Proportional band) [2CH Operation data]
1D0224	      2.TI (Integral time) [2CH Operation data]
1D0225	      2.TD (Derivative time) [2CH Operation data]
1D0226	      2.MR (Manual reset) [2CH Operation data]
1D0227	      2.HYS (Hysteresis) [2CH Operation data]
1D0228	      2.DR (Direct/reverse action switching) [2CH Operation data]
1D0230	      3.SP (Target setpoint) [2CH Operation data]
1D0231	      3.A1 (Alarm setpoints for alarm 1) [2CH Operation data]
1D0232	      3.A2 (Alarm setpoints for alarm 2) [2CH Operation data]
1D0233	      3.PB (Proportional band) [2CH Operation data]
1D0234	      3.TI (Integral time) [2CH Operation data]
1D0235	      3.TD (Derivative time) [2CH Operation data]
1D0236	      3.MR (Manual reset) [2CH Operation data]
1D0237	      3.HYS (Hysteresis) [2CH Operation data]
1D0238	      3.DR (Direct/reverse action switching) [2CH Operation data]
1D0240	      4.SP (Target setpoint) [2CH Operation data]
1D0241	      4.A1 (Alarm setpoints for alarm 1) [2CH Operation data]
1D0242	      4.A2 (Alarm setpoints for alarm 2) [2CH Operation data]
1D0243	      4.PB (Proportional band) [2CH Operation data]
1D0244	      4.TI (Integral time) [2CH Operation data]
1D0245	      4.TD (Derivative time) [2CH Operation data]
1D0246	      4.MR (Manual reset) [2CH Operation data]
1D0247	      4.HYS (Hysteresis) [2CH Operation data]
1D0248	      4.DR (Direct/reverse action switching) [2CH Operation data]
1D0250	      5.SP (Target setpoint) [2CH Operation data]
1D0251	      5.A1 (Alarm setpoints for alarm 1) [2CH Operation data]
1D0252	      5.A2 (Alarm setpoints for alarm 2) [2CH Operation data]
1D0253	      5.PB (Proportional band) [2CH Operation data]
1D0254	      5.TI (Integral time) [2CH Operation data]
1D0255	      5.TD (Derivative time) [2CH Operation data]
1D0256	      5.MR (Manual reset) [2CH Operation data]
1D0257	      5.HYS (Hysteresis) [2CH Operation data]
1D0258	      5.DR (Direct/reverse action switching) [2CH Operation data]
1D0260	      6.SP (Target setpoint) [2CH Operation data]
1D0261	      6.A1 (Alarm setpoints for alarm 1) [2CH Operation data]
1D0262	      6.A2 (Alarm setpoints for alarm 2) [2CH Operation data]
1D0263	      6.PB (Proportional band) [2CH Operation data]
1D0264	      6.TI (Integral time) [2CH Operation data]
1D0265	      6.TD (Derivative time) [2CH Operation data]
1D0266	      6.MR (Manual reset) [2CH Operation data]
1D0267	      6.HYS (Hysteresis) [2CH Operation data]
1D0268	      6.DR (Direct/reverse action switching) [2CH Operation data]
1D0270	      7.SP (Target setpoint) [2CH Operation data]
1D0271	      7.A1 (Alarm setpoints for alarm 1) [2CH Operation data]
1D0272	      7.A2 (Alarm setpoints for alarm 2) [2CH Operation data]
1D0273	      7.PB (Proportional band) [2CH Operation data]
1D0274	      7.TI (Integral time) [2CH Operation data]
1D0275	      7.TD (Derivative time) [2CH Operation data]
1D0276	      7.MR (Manual reset) [2CH Operation data]
1D0277	      7.HYS (Hysteresis) [2CH Operation data]
1D0278	      7.DR (Direct/reverse action switching) [2CH Operation data]
1D0280	      8.SP (Target setpoint) [2CH Operation data]
1D0281	      8.A1 (Alarm setpoints for alarm 1) [2CH Operation data]
1D0282	      8.A2 (Alarm setpoints for alarm 2) [2CH Operation data]
1D0283	      8.PB (Proportional band) [2CH Operation data]
1D0284	      8.TI (Integral time) [2CH Operation data]
1D0285	      8.TD (Derivative time) [2CH Operation data]
1D0286	      8.MR (Manual reset) [2CH Operation data]
1D0287	      8.HYS (Hysteresis) [2CH Operation data]
1D0288	      8.DR (Direct/reverse action switching) [2CH Operation data]
1D0310	      1.SP (Target setpoint) [3CH Operation data]
1D0311	      1.A1 (Alarm setpoints for alarm 1) [3CH Operation data]
1D0312	      1.A2 (Alarm setpoints for alarm 2) [3CH Operation data]
1D0313	      1.PB (Proportional band) [3CH Operation data]
1D0314	      1.TI (Integral time) [3CH Operation data]
1D0315	      1.TD (Derivative time) [3CH Operation data]
1D0316	      1.MR (Manual reset) [3CH Operation data]
1D0317	      1.HYS (Hysteresis) [3CH Operation data]
1D0318	      1.DR (Direct/reverse action switching) [3CH Operation data]
1D0320	      2.SP (Target setpoint) [3CH Operation data]
1D0321	      2.A1 (Alarm setpoints for alarm 1) [3CH Operation data]
1D0322	      2.A2 (Alarm setpoints for alarm 2) [3CH Operation data]
1D0323	      2.PB (Proportional band) [3CH Operation data]
1D0324	      2.TI (Integral time) [3CH Operation data]
1D0325	      2.TD (Derivative time) [3CH Operation data]
1D0326	      2.MR (Manual reset) [3CH Operation data]
1D0327	      2.HYS (Hysteresis) [3CH Operation data]
1D0328	      2.DR (Direct/reverse action switching) [3CH Operation data]
1D0330	      3.SP (Target setpoint) [3CH Operation data]
1D0331	      3.A1 (Alarm setpoints for alarm 1) [3CH Operation data]
1D0332	      3.A2 (Alarm setpoints for alarm 2) [3CH Operation data]
1D0333	      3.PB (Proportional band) [3CH Operation data]
1D0334	      3.TI (Integral time) [3CH Operation data]
1D0335	      3.TD (Derivative time) [3CH Operation data]
1D0336	      3.MR (Manual reset) [3CH Operation data]
1D0337	      3.HYS (Hysteresis) [3CH Operation data]
1D0338	      3.DR (Direct/reverse action switching) [3CH Operation data]
1D0340	      4.SP (Target setpoint) [3CH Operation data]
1D0341	      4.A1 (Alarm setpoints for alarm 1) [3CH Operation data]
1D0342	      4.A2 (Alarm setpoints for alarm 2) [3CH Operation data]
1D0343	      4.PB (Proportional band) [3CH Operation data]
1D0344	      4.TI (Integral time) [3CH Operation data]
1D0345	      4.TD (Derivative time) [3CH Operation data]
1D0346	      4.MR (Manual reset) [3CH Operation data]
1D0347	      4.HYS (Hysteresis) [3CH Operation data]
1D0348	      4.DR (Direct/reverse action switching) [3CH Operation data]
1D0350	      5.SP (Target setpoint) [3CH Operation data]
1D0351	      5.A1 (Alarm setpoints for alarm 1) [3CH Operation data]
1D0352	      5.A2 (Alarm setpoints for alarm 2) [3CH Operation data]
1D0353	      5.PB (Proportional band) [3CH Operation data]
1D0354	      5.TI (Integral time) [3CH Operation data]
1D0355	      5.TD (Derivative time) [3CH Operation data]
1D0356	      5.MR (Manual reset) [3CH Operation data]
1D0357	      5.HYS (Hysteresis) [3CH Operation data]
1D0358	      5.DR (Direct/reverse action switching) [3CH Operation data]
1D0360	      6.SP (Target setpoint) [3CH Operation data]
1D0361	      6.A1 (Alarm setpoints for alarm 1) [3CH Operation data]
1D0362	      6.A2 (Alarm setpoints for alarm 2) [3CH Operation data]
1D0363	      6.PB (Proportional band) [3CH Operation data]
1D0364	      6.TI (Integral time) [3CH Operation data]
1D0365	      6.TD (Derivative time) [3CH Operation data]
1D0366	      6.MR (Manual reset) [3CH Operation data]
1D0367	      6.HYS (Hysteresis) [3CH Operation data]
1D0368	      6.DR (Direct/reverse action switching) [3CH Operation data]
1D0370	      7.SP (Target setpoint) [3CH Operation data]
1D0371	      7.A1 (Alarm setpoints for alarm 1) [3CH Operation data]
1D0372	      7.A2 (Alarm setpoints for alarm 2) [3CH Operation data]
1D0373	      7.PB (Proportional band) [3CH Operation data]
1D0374	      7.TI (Integral time) [3CH Operation data]
1D0375	      7.TD (Derivative time) [3CH Operation data]
1D0376	      7.MR (Manual reset) [3CH Operation data]
1D0377	      7.HYS (Hysteresis) [3CH Operation data]
1D0378	      7.DR (Direct/reverse action switching) [3CH Operation data]
1D0380	      8.SP (Target setpoint) [3CH Operation data]
1D0381	      8.A1 (Alarm setpoints for alarm 1) [3CH Operation data]
1D0382	      8.A2 (Alarm setpoints for alarm 2) [3CH Operation data]
1D0383	      8.PB (Proportional band) [3CH Operation data]
1D0384	      8.TI (Integral time) [3CH Operation data]
1D0385	      8.TD (Derivative time) [3CH Operation data]
1D0386	      8.MR (Manual reset) [3CH Operation data]
1D0387	      8.HYS (Hysteresis) [3CH Operation data]
1D0388	      8.DR (Direct/reverse action switching) [3CH Operation data]
1D0410	      1.SP (Target setpoint) [4CH Operation data]
1D0411	      1.A1 (Alarm setpoints for alarm 1) [4CH Operation data]
1D0412	      1.A2 (Alarm setpoints for alarm 2) [4CH Operation data]
1D0413	      1.PB (Proportional band) [4CH Operation data]
1D0414	      1.TI (Integral time) [4CH Operation data]
1D0415	      1.TD (Derivative time) [4CH Operation data]
1D0416	      1.MR (Manual reset) [4CH Operation data]
1D0417	      1.HYS (Hysteresis) [4CH Operation data]
1D0418	      1.DR (Direct/reverse action switching) [4CH Operation data]
1D0420	      2.SP (Target setpoint) [4CH Operation data]
1D0421	      2.A1 (Alarm setpoints for alarm 1) [4CH Operation data]
1D0422	      2.A2 (Alarm setpoints for alarm 2) [4CH Operation data]
1D0423	      2.PB (Proportional band) [4CH Operation data]
1D0424	      2.TI (Integral time) [4CH Operation data]
1D0425	      2.TD (Derivative time) [4CH Operation data]
1D0426	      2.MR (Manual reset) [4CH Operation data]
1D0427	      2.HYS (Hysteresis) [4CH Operation data]
1D0428	      2.DR (Direct/reverse action switching) [4CH Operation data]
1D0430	      3.SP (Target setpoint) [4CH Operation data]
1D0431	      3.A1 (Alarm setpoints for alarm 1) [4CH Operation data]
1D0432	      3.A2 (Alarm setpoints for alarm 2) [4CH Operation data]
1D0433	      3.PB (Proportional band) [4CH Operation data]
1D0434	      3.TI (Integral time) [4CH Operation data]
1D0435	      3.TD (Derivative time) [4CH Operation data]
1D0436	      3.MR (Manual reset) [4CH Operation data]
1D0437	      3.HYS (Hysteresis) [4CH Operation data]
1D0438	      3.DR (Direct/reverse action switching) [4CH Operation data]
1D0440	      4.SP (Target setpoint) [4CH Operation data]
1D0441	      4.A1 (Alarm setpoints for alarm 1) [4CH Operation data]
1D0442	      4.A2 (Alarm setpoints for alarm 2) [4CH Operation data]
1D0443	      4.PB (Proportional band) [4CH Operation data]
1D0444	      4.TI (Integral time) [4CH Operation data]
1D0445	      4.TD (Derivative time) [4CH Operation data]
1D0446	      4.MR (Manual reset) [4CH Operation data]
1D0447	      4.HYS (Hysteresis) [4CH Operation data]
1D0448	      4.DR (Direct/reverse action switching) [4CH Operation data]
1D0450	      5.SP (Target setpoint) [4CH Operation data]
1D0451	      5.A1 (Alarm setpoints for alarm 1) [4CH Operation data]
1D0452	      5.A2 (Alarm setpoints for alarm 2) [4CH Operation data]
1D0453	      5.PB (Proportional band) [4CH Operation data]
1D0454	      5.TI (Integral time) [4CH Operation data]
1D0455	      5.TD (Derivative time) [4CH Operation data]
1D0456	      5.MR (Manual reset) [4CH Operation data]
1D0457	      5.HYS (Hysteresis) [4CH Operation data]
1D0458	      5.DR (Direct/reverse action switching) [4CH Operation data]
1D0460	      6.SP (Target setpoint) [4CH Operation data]
1D0461	      6.A1 (Alarm setpoints for alarm 1) [4CH Operation data]
1D0462	      6.A2 (Alarm setpoints for alarm 2) [4CH Operation data]
1D0463	      6.PB (Proportional band) [4CH Operation data]
1D0464	      6.TI (Integral time) [4CH Operation data]
1D0465	      6.TD (Derivative time) [4CH Operation data]
1D0466	      6.MR (Manual reset) [4CH Operation data]
1D0467	      6.HYS (Hysteresis) [4CH Operation data]
1D0468	      6.DR (Direct/reverse action switching) [4CH Operation data]
1D0470	      7.SP (Target setpoint) [4CH Operation data]
1D0471	      7.A1 (Alarm setpoints for alarm 1) [4CH Operation data]
1D0472	      7.A2 (Alarm setpoints for alarm 2) [4CH Operation data]
1D0473	      7.PB (Proportional band) [4CH Operation data]
1D0474	      7.TI (Integral time) [4CH Operation data]
1D0475	      7.TD (Derivative time) [4CH Operation data]
1D0476	      7.MR (Manual reset) [4CH Operation data]
1D0477	      7.HYS (Hysteresis) [4CH Operation data]
1D0478	      7.DR (Direct/reverse action switching) [4CH Operation data]
1D0480	      8.SP (Target setpoint) [4CH Operation data]
1D0481	      8.A1 (Alarm setpoints for alarm 1) [4CH Operation data]
1D0482	      8.A2 (Alarm setpoints for alarm 2) [4CH Operation data]
1D0483	      8.PB (Proportional band) [4CH Operation data]
1D0484	      8.TI (Integral time) [4CH Operation data]
1D0485	      8.TD (Derivative time) [4CH Operation data]
1D0486	      8.MR (Manual reset) [4CH Operation data]
1D0487	      8.HYS (Hysteresis) [4CH Operation data]
1D0488	      8.DR (Direct/reverse action switching) [4CH Operation data]
1D0510	      1.SP (Target setpoint) [All CH1~CH4 setting]
1D0511	      1.A1 (Alarm setpoints for alarm 1) [All CH1~CH4 setting]
1D0512	      1.A2 (Alarm setpoints for alarm 2) [All CH1~CH4 setting]
1D0513	      1.PB (Proportional band) [All CH1~CH4 setting]
1D0514	      1.TI (Integral time) [All CH1~CH4 setting]
1D0515	      1.TD (Derivative time) [All CH1~CH4 setting]
1D0516	      1.MR (Manual reset) [All CH1~CH4 setting]
1D0517	      1.HYS (Hysteresis) [All CH1~CH4 setting]
1D0518	      1.DR (Direct/reverse action switching) [All CH1~CH4 setting]
1D0520	      2.SP (Target setpoint) [All CH1~CH4 setting]
1D0521	      2.A1 (Alarm setpoints for alarm 1) [All CH1~CH4 setting]
1D0522	      2.A2 (Alarm setpoints for alarm 2) [All CH1~CH4 setting]
1D0523	      2.PB (Proportional band) [All CH1~CH4 setting]
1D0524	      2.TI (Integral time) [All CH1~CH4 setting]
1D0525	      2.TD (Derivative time) [All CH1~CH4 setting]
1D0526	      2.MR (Manual reset) [All CH1~CH4 setting]
1D0527	      2.HYS (Hysteresis) [All CH1~CH4 setting]
1D0528	      2.DR (Direct/reverse action switching) [All CH1~CH4 setting]
1D0530	      3.SP (Target setpoint) [All CH1~CH4 setting]
1D0531	      3.A1 (Alarm setpoints for alarm 1) [All CH1~CH4 setting]
1D0532	      3.A2 (Alarm setpoints for alarm 2) [All CH1~CH4 setting]
1D0533	      3.PB (Proportional band) [All CH1~CH4 setting]
1D0534	      3.TI (Integral time) [All CH1~CH4 setting]
1D0535	      3.TD (Derivative time) [All CH1~CH4 setting]
1D0536	      3.MR (Manual reset) [All CH1~CH4 setting]
1D0537	      3.HYS (Hysteresis) [All CH1~CH4 setting]
1D0538	      3.DR (Direct/reverse action switching) [All CH1~CH4 setting]
1D0540	      4.SP (Target setpoint) [All CH1~CH4 setting]
1D0541	      4.A1 (Alarm setpoints for alarm 1) [All CH1~CH4 setting]
1D0542	      4.A2 (Alarm setpoints for alarm 2) [All CH1~CH4 setting]
1D0543	      4.PB (Proportional band) [All CH1~CH4 setting]
1D0544	      4.TI (Integral time) [All CH1~CH4 setting]
1D0545	      4.TD (Derivative time) [All CH1~CH4 setting]
1D0546	      4.MR (Manual reset) [All CH1~CH4 setting]
1D0547	      4.HYS (Hysteresis) [All CH1~CH4 setting]
1D0548	      4.DR (Direct/reverse action switching) [All CH1~CH4 setting]
1D0550	      5.SP (Target setpoint) [All CH1~CH4 setting]
1D0551	      5.A1 (Alarm setpoints for alarm 1) [All CH1~CH4 setting]
1D0552	      5.A2 (Alarm setpoints for alarm 2) [All CH1~CH4 setting]
1D0553	      5.PB (Proportional band) [All CH1~CH4 setting]
1D0554	      5.TI (Integral time) [All CH1~CH4 setting]
1D0555	      5.TD (Derivative time) [All CH1~CH4 setting]
1D0556	      5.MR (Manual reset) [All CH1~CH4 setting]
1D0557	      5.HYS (Hysteresis) [All CH1~CH4 setting]
1D0558	      5.DR (Direct/reverse action switching) [All CH1~CH4 setting]
1D0560	      6.SP (Target setpoint) [All CH1~CH4 setting]
1D0561	      6.A1 (Alarm setpoints for alarm 1) [All CH1~CH4 setting]
1D0562	      6.A2 (Alarm setpoints for alarm 2) [All CH1~CH4 setting]
1D0563	      6.PB (Proportional band) [All CH1~CH4 setting]
1D0564	      6.TI (Integral time) [All CH1~CH4 setting]
1D0565	      6.TD (Derivative time) [All CH1~CH4 setting]
1D0566	      6.MR (Manual reset) [All CH1~CH4 setting]
1D0567	      6.HYS (Hysteresis) [All CH1~CH4 setting]
1D0568	      6.DR (Direct/reverse action switching) [All CH1~CH4 setting]
1D0570	      7.SP (Target setpoint) [All CH1~CH4 setting]
1D0571	      7.A1 (Alarm setpoints for alarm 1) [All CH1~CH4 setting]
1D0572	      7.A2 (Alarm setpoints for alarm 2) [All CH1~CH4 setting]
1D0573	      7.PB (Proportional band) [All CH1~CH4 setting]
1D0574	      7.TI (Integral time) [All CH1~CH4 setting]
1D0575	      7.TD (Derivative time) [All CH1~CH4 setting]
1D0576	      7.MR (Manual reset) [All CH1~CH4 setting]
1D0577	      7.HYS (Hysteresis) [All CH1~CH4 setting]
1D0578	      7.DR (Direct/reverse action switching) [All CH1~CH4 setting]
1D0580	      8.SP (Target setpoint) [All CH1~CH4 setting]
1D0581	      8.A1 (Alarm setpoints for alarm 1) [All CH1~CH4 setting]
1D0582	      8.A2 (Alarm setpoints for alarm 2) [All CH1~CH4 setting]
1D0583	      8.PB (Proportional band) [All CH1~CH4 setting]
1D0584	      8.TI (Integral time) [All CH1~CH4 setting]
1D0585	      8.TD (Derivative time) [All CH1~CH4 setting]
1D0586	      8.MR (Manual reset) [All CH1~CH4 setting]
1D0587	      8.HYS (Hysteresis) [All CH1~CH4 setting]
1D0588	      8.DR (Direct/reverse action switching) [All CH1~CH4 setting]
1D0600	      SC (SUPER function selection) [1CH Setup data]
1D0601	      AT (Auto-tuning selection) [1CH Setup data]
1D0602	      SP.UP (Setpoint ramp-up rate setting) [1CH Setup data]
1D0603	      SP.DN (Setpoint ramp-down rate setting) [1CH Setup data]
1D0604	      SP.R (Ramp-rate time unit setting) [1CH Setup data]
1D0605	      FL (Filter) [1CH Setup data]
1D0606	      BS (Input compensation bias) [1CH Setup data]
1D0607	      A/M (AUTO/MAN modes) [1CH Setup data]
1D0608	      R/S (STOP/RUN modes) [1CH Setup data]
1D0609	      MANOUT (Manual output value) [1CH Setup data]
1D0610	      PROUT (Preset output value) [1CH Setup data]
1D0611	      SPNO (Group SP number) [1CH Setup data]
1D0612	      HB (Heater current measurement) [1CH Setup data]
1D0613	      AL1 (Alarm-1 type) [1CH Setup data]
1D0614	      AL2 (Alarm-2 type) [1CH Setup data]
1D0615	      HY1 (Alarm-1 hysteresis) [1CH Setup data]
1D0616	      HY2 (Alarm-2 hysteresis) [1CH Setup data]
1D0617	      CT (Cycle time) [1CH Setup data]
1D0618	      OH (Upper limit of output) [1CH Setup data]
1D0619	      OL (Lower limit of output) [1CH Setup data]
1D0620	      RST (Restart mode) [1CH Setup data]
1D0621	      ORBND (ON/OFF rate detection width) [1CH Setup data]
1D0622	      ORHI (ON/OFF rate upper limit) [1CH Setup data]
1D0623	      ORLO (ON/OFF rate lower limit) [1CH Setup data]
1D0624	      USE (use/unuse) [1CH Setup data]
1D0625	      A3 (Alarm-3 setpoint) [1CH Setup data]
1D0626	      AL3 (Alarm-3 type) [1CH Setup data]
1D0627	      HY3 (Alarm-3 hysteresis) [1CH Setup data]
1D0650	      PD (Decimal point position) [1CH Setup data]
1D0651	      RH (Instrument range upper limit) [1CH Setup data]
1D0652	      RL (Instrument range lower limit) [1CH Setup data]
1D0653	      ARSL (ARM action mode) [1CH Setup data]
1D0654	      MD (Channel action mode) [1CH Setup data]
1D0700	      SC (SUPER function selection) [2CH Setup data]
1D0701	      AT (Auto-tuning selection) [2CH Setup data]
1D0702	      SP.UP (Setpoint ramp-up rate setting) [2CH Setup data]
1D0703	      SP.DN (Setpoint ramp-down rate setting) [2CH Setup data]
1D0704	      SP.R (Rate time unit) [2CH Setup data]
1D0705	      FL (Filter) [2CH Setup data]
1D0706	      BS (Input compensation bias) [2CH Setup data]
1D0707	      A/M (AUTO/MAN modes) [2CH Setup data]
1D0708	      R/S (STOP/RUN modes) [2CH Setup data]
1D0709	      MANOUT (ManualOutput value) [2CH Setup data]
1D0710	      PROUT (PresetOutput value) [2CH Setup data]
1D0711	      SPNO (Group SP number) [2CH Setup data]
1D0712	      HB (Heater current measurement) [2CH Setup data]
1D0713	      AL1 (Alarm-1 type) [2CH Setup data]
1D0714	      AL2 (Alarm-2 type) [2CH Setup data]
1D0715	      HY1 (Alarm-1 hysteresis) [2CH Setup data]
1D0716	      HY2 (Alarm-2 hysteresis) [2CH Setup data]
1D0717	      CT (Cycle time) [2CH Setup data]
1D0718	      OH (Upper limit of output) [2CH Setup data]
1D0719	      OL (Lower limit of output) [2CH Setup data]
1D0720	      RST (Restart mode) [2CH Setup data]
1D0721	      ORBND (ON/OFF rate detection width) [2CH Setup data]
1D0722	      ORHI (ON/OFF rate upper limit) [2CH Setup data]
1D0723	      ORLO (ON/OFF rate lower limit) [2CH Setup data]
1D0724	      USE (use/unuse) [2CH Setup data]
1D0725	      A3 (Alarm-3 setpoint) [2CH Setup data]
1D0726	      AL3 (Alarm-3 type) [2CH Setup data]
1D0727	      HY3 (Alarm-3 hysteresis) [2CH Setup data]
1D0750	      PD (Decimal point position) [2CH Setup data]
1D0751	      RH (Instrument range upper limit) [2CH Setup data]
1D0752	      RL (Instrument range lower limit) [2CH Setup data]
1D0753	      ARSL (ARM action mode) [2CH Setup data]
1D0754	      MD (Channel action mode) [2CH Setup data]
1D0800	      SC (SUPER function selection) [3CH Setup data]
1D0801	      AT (Auto-tuning selection) [3CH Setup data]
1D0802	      SP.UP (Setpoint ramp-up rate setting) [3CH Setup data]
1D0803	      SP.DN (Setpoint ramp-down rate setting) [3CH Setup data]
1D0804	      SP.R (Rate time unit) [3CH Setup data]
1D0805	      FL (Filter) [3CH Setup data]
1D0806	      BS (Input compensation bias) [3CH Setup data]
1D0807	      A/M (AUTO/MAN modes) [3CH Setup data]
1D0808	      R/S (STOP/RUN modes) [3CH Setup data]
1D0809	      MANOUT (ManualOutput value) [3CH Setup data]
1D0810	      PROUT (PresetOutput value) [3CH Setup data]
1D0811	      SPNO (Group SP number) [3CH Setup data]
1D0812	      HB (Heater current measurement) [3CH Setup data]
1D0813	      AL1 (Alarm-1 type) [3CH Setup data]
1D0814	      AL2 (Alarm-2 type) [3CH Setup data]
1D0815	      HY1 (Alarm-1 hysteresis) [3CH Setup data]
1D0816	      HY2 (Alarm-2 hysteresis) [3CH Setup data]
1D0817	      CT (Cycle time) [3CH Setup data]
1D0818	      OH (Upper limit of output) [3CH Setup data]
1D0819	      OL (Lower limit of output) [3CH Setup data]
1D0820	      RST (Restart mode) [3CH Setup data]
1D0821	      ORBND (ON/OFF rate detection width) [3CH Setup data]
1D0822	      ORHI (ON/OFF rate upper limit) [3CH Setup data]
1D0823	      ORLO (ON/OFF rate lower limit) [3CH Setup data]
1D0824	      USE (use/unuse) [3CH Setup data]
1D0825	      A3 (Alarm-3 setpoint) [3CH Setup data]
1D0826	      AL3 (Alarm-3 type) [3CH Setup data]
1D0827	      HY3 (Alarm-3 hysteresis) [3CH Setup data]
1D0850	      PD (Decimal point position) [3CH Setup data]
1D0851	      RH (Instrument range upper limit) [3CH Setup data]
1D0852	      RL (Instrument range lower limit) [3CH Setup data]
1D0853	      ARSL (ARM action mode) [3CH Setup data]
1D0854	      MD (Channel action mode) [3CH Setup data]
1D0900	      SC (SUPER function selection) [4CH Setup data]
1D0901	      AT (Auto-tuning selection) [4CH Setup data]
1D0902	      SP.UP (Setpoint ramp-up rate setting) [4CH Setup data]
1D0903	      SP.DN (Setpoint ramp-down rate setting) [4CH Setup data]
1D0904	      SP.R (Rate time unit) [4CH Setup data]
1D0905	      FL (Filter) [4CH Setup data]
1D0906	      BS (Input compensation bias) [4CH Setup data]
1D0907	      A/M (AUTO/MAN modes) [4CH Setup data]
1D0908	      R/S (STOP/RUN modes) [4CH Setup data]
1D0909	      MANOUT (Manual output value) [4CH Setup data]
1D0910	      PROUT (Preset output value) [4CH Setup data]
1D0911	      SPNO (Group SP number) [4CH Setup data]
1D0912	      HB (Heater current measurement) [4CH Setup data]
1D0913	      AL1 (Alarm-1 type) [4CH Setup data]
1D0914	      AL2 (Alarm-2 type) [4CH Setup data]
1D0915	      HY1 (Alarm-1 hysteresis) [4CH Setup data]
1D0916	      HY2 (Alarm-2 hysteresis) [4CH Setup data]
1D0917	      CT (Cycle time) [4CH Setup data]
1D0918	      OH (Upper limit of output) [4CH Setup data]
1D0919	      OL (Lower limit of output) [4CH Setup data]
1D0920	      RST (Restart mode) [4CH Setup data]
1D0921	      ORBND (ON/OFF rate detection width) [4CH Setup data]
1D0922	      ORHI (ON/OFF rate upper limit) [4CH Setup data]
1D0923	      ORLO (ON/OFF rate lower limit) [4CH Setup data]
1D0924	      USE (use/unuse) [4CH Setup data]
1D0925	      A3 (Alarm-3 setpoint) [4CH Setup data]
1D0926	      AL3 (Alarm-3 type) [4CH Setup data]
1D0927	      HY3 (Alarm-3 hysteresis) [4CH Setup data]
1D0950	      PD (Decimal point position) [4CH Setup data]
1D0951	      RH (Instrument range upper limit) [4CH Setup data]
1D0952	      RL (Instrument range lower limit) [4CH Setup data]
1D0953	      ARSL (ARM action mode) [4CH Setup data]
1D0954	      MD (Channel action mode) [4CH Setup data]
1D0955	      STEUP (Setup mode) [All CH Setup data]
1D0956	      IN (Input type) [All CH Setup data]
1D1000	      SC (SUPER function selection) [All CH1~CH4 setting]
1D1001	      AT (Auto-tuning selection) [All CH1~CH4 setting]
1D1002	      SP.UP (Setpoint ramp-up rate setting) [All CH1~CH4 setting]
1D1003	      SP.DN (Setpoint ramp-down rate setting) [All CH1~CH4 setting]
1D1004	      SP.R (Rate time unit) [All CH1~CH4 setting]
1D1005	      FL (Filter) [All CH1~CH4 setting]
1D1006	      BS (Input compensation bias) [All CH1~CH4 setting]
1D1007	      A/M (AUTO/MAN modes) [All CH1~CH4 setting]
1D1008	      R/S (STOP/RUN modes) [All CH1~CH4 setting]
1D1009	      MANOUT (ManualOutput value) [All CH1~CH4 setting]
1D1010	      PROUT (PresetOutput value) [All CH1~CH4 setting]
1D1011	      SPNO (Group SP number) [All CH1~CH4 setting]
1D1012	      HB (Heater current measurement) [All CH1~CH4 setting]
1D1013	      AL1 (Alarm-1 type) [All CH1~CH4 setting]
1D1014	      AL2 (Alarm-2 type) [All CH1~CH4 setting]
1D1015	      HY1 (Alarm-1 hysteresis) [All CH1~CH4 setting]
1D1016	      HY2 (Alarm-2 hysteresis) [All CH1~CH4 setting]
1D1017	      CT (Cycle time) [All CH1~CH4 setting]
1D1018	      OH (Upper limit of output) [All CH1~CH4 setting]
1D1019	      OL (Lower limit of output) [All CH1~CH4 setting]
1D1020	      RST (Restart mode) [All CH1~CH4 setting]
1D1021	      ORBND (ON/OFF rate detection width) [All CH1~CH4 setting]
1D1022	      ORHI (ON/OFF rate upper limit) [All CH1~CH4 setting]
1D1023	      ORLO (ON/OFF rate lower limit) [All CH1~CH4 setting]
1D1024	      USE (use/unuse) [All CH1~CH4 setting]
[D-SigDataEnd]-B

[D-SigData-2]-B
2D0001.00    AL1 relay
2D0001.04    AL2 relay
2D0001.08    HB relay
2D0001.12    ALM lamp
2D0001.13    ERR lamp
2D0002.00    AL1 [CH5]
2D0002.01    AL2 [CH5]
2D0002.02    HB(AL3) [CH5]
2D0002.04    Burnout [CH5]
2D0002.05    +Over [CH5]
2D0002.06    -Over [CH5]
2D0002.08    ADC error [CH5]
2D0002.09    RJC error [CH5]
2D0002.10    Heater Shield [CH5]
2D0002.12    System data error [CH5]
2D0002.13    Calibration value error [CH5]
2D0002.14    Parameter erroe [CH5]
2D0003.00    AL1 [CH6]
2D0003.01    AL2 [CH6]
2D0003.02    HB(AL3) [CH6]
2D0003.04    Burnout [CH6]
2D0003.05    +Over [CH6]
2D0003.06    -Over [CH6]
2D0003.08    ADC error [CH6]
2D0003.09    RJC error [CH6]
2D0003.10    Heater Shield [CH6]
2D0003.12    System data error [CH6]
2D0003.13    Calibration value error [CH6]
2D0003.14    Parameter error [CH6]
2D0004.00    AL1 [CH7]
2D0004.01    AL2 [CH7]
2D0004.02    HB(AL3) [CH7]
2D0004.04    Burnout [CH7]
2D0004.05    +Over [CH7]
2D0004.06    -Over [CH7]
2D0004.08    ADC error [CH7]
2D0004.09    RJC error [CH7]
2D0004.10    Heater Shield [CH7]
2D0004.12    System data error [CH7]
2D0004.13    Calibration value error [CH7]
2D0004.14    Parameter error [CH7]
2D0005.00    AL1 [CH8]
2D0005.01    AL2 [CH8]
2D0005.02    HB(AL3) [CH8]
2D0005.04    Burnout [CH8]
2D0005.05    +Over [CH8]
2D0005.06    -Over [CH8]
2D0005.08    ADC error [CH8]
2D0005.09    RJC error [CH8]
2D0005.10    Heater Shield [CH8]
2D0005.12    System data error [CH8]
2D0005.13    Calibration value error [CH8]
2D0005.14    Parameter error [CH8]
2D0006	      5.PV (Process value) [CH5]
2D0007	      6.PV (Process value) [CH6]
2D0008	      7.PV (Process value) [CH7]
2D0009	      8.PV (Process value) [CH8]
2D0010	      5.CSP (Current target setpoint) [CH5]
2D0011	      6.CSP (Current target setpoint) [CH6]
2D0012	      7.CSP (Current target setpoint) [CH7]
2D0013	      8.CSP (Current target setpoint) [CH8]
2D0014	      5.OUT (Output value) [CH5]
2D0015	      6.OUT (Output value) [CH6]
2D0016	      7.OUT (Output value) [CH7]
2D0017	      8.OUT (Output value) [CH8]
2D0018.00    0:AUTO 1:MAN [CH5]
2D0018.04    0:RUN 1:STOP [CH5]
2D0018.12    0:Auto-tuning OFF 1:Auto-tuning ON [CH5]
2D0019.00    0:AUTO 1:MAN [CH6]
2D0019.04    0:RUN 1:STOP [CH6]
2D0019.12    0:Auto-tuning OFF 1:Auto-tuning ON [CH6]
2D0020.00    0:AUTO 1:MAN [CH7]
2D0020.04    0:RUN 1:STOP [CH7]
2D0020.12    0:Auto-tuning OFF 1:Auto-tuning ON [CH7]
2D0021.00    0:AUTO 1:MAN [CH8]
2D0021.04    0:RUN 1:STOP [CH8]
2D0021.12    0:Auto-tuning OFF 1:Auto-tuning ON [CH8]
2D0022	      5.DEV (Deviation) [CH5]
2D0023	      6.DEV (Deviation) [CH6]
2D0024	      7.DEV (Deviation) [CH7]
2D0025	      8.DEV (Deviation) [CH8]
2D0026	      5.SPNO (Set group number) [CH5]
2D0027	      6.SPNO (Set group number) [CH6]
2D0028	      7.SPNO (Set group number) [CH7]
2D0029	      8.SPNO (Set group number) [CH8]
2D0030	      5.HC (Heater current value) [CH5]
2D0031	      6.HC (Heater current value) [CH6]
2D0032	      7.HC (Heater current value) [CH7]
2D0033	      8.HC (Heater current value) [CH8]
2D0090	      (REG SL)
2D0091	      (100%)
2D0092	      (75%)
2D0093	      (50%)
2D0094	      (25%)
2D0095	      (0%)
2D0110	      1.SP (Target setpoint) [5CH Operation data]
2D0111	      1.A1 (Alarm setpoints for alarm 1) [5CH Operation data]
2D0112	      1.A2 (Alarm setpoints for alarm 2) [5CH Operation data]
2D0113	      1.PB (Proportional band) [5CH Operation data]
2D0114	      1.TI (Integral time) [5CH Operation data]
2D0115	      1.TD (Derivative time) [5CH Operation data]
2D0116	      1.MR (Manual reset) [5CH Operation data]
2D0117	      1.HYS (Hysteresis) [5CH Operation data]
2D0118	      1.DR (Direct/reverse action switching) [5CH Operation data]
2D0120	      2.SP (Target setpoint) [5CH Operation data]
2D0121	      2.A1 (Alarm setpoints for alarm 1) [5CH Operation data]
2D0122	      2.A2 (Alarm setpoints for alarm 2) [5CH Operation data]
2D0123	      2.PB (Proportional band) [5CH Operation data]
2D0124	      2.TI (Integral time) [5CH Operation data]
2D0125	      2.TD (Derivative time) [5CH Operation data]
2D0126	      2.MR (Manual reset) [5CH Operation data]
2D0127	      2.HYS (Hysteresis) [5CH Operation data]
2D0128	      2.DR (Direct/reverse action switching) [5CH Operation data]
2D0130	      3.SP (Target setpoint) [5CH Operation data]
2D0131	      3.A1 (Alarm setpoints for alarm 1) [5CH Operation data]
2D0132	      3.A2 (Alarm setpoints for alarm 2) [5CH Operation data]
2D0133	      3.PB (Proportional band) [5CH Operation data]
2D0134	      3.TI (Integral time) [5CH Operation data]
2D0135	      3.TD (Derivative time) [5CH Operation data]
2D0136	      3.MR (Manual reset) [5CH Operation data]
2D0137	      3.HYS (Hysteresis) [5CH Operation data]
2D0138	      3.DR (Direct/reverse action switching) [5CH Operation data]
2D0140	      4.SP (Target setpoint) [5CH Operation data]
2D0141	      4.A1 (Alarm setpoints for alarm 1) [5CH Operation data]
2D0142	      4.A2 (Alarm setpoints for alarm 2) [5CH Operation data]
2D0143	      4.PB (Proportional band) [5CH Operation data]
2D0144	      4.TI (Integral time) [5CH Operation data]
2D0145	      4.TD (Derivative time) [5CH Operation data]
2D0146	      4.MR (Manual reset) [5CH Operation data]
2D0147	      4.HYS (Hysteresis) [5CH Operation data]
2D0148	      4.DR (Direct/reverse action switching) [5CH Operation data]
2D0150	      5.SP (Target setpoint) [5CH Operation data]
2D0151	      5.A1 (Alarm setpoints for alarm 1) [5CH Operation data]
2D0152	      5.A2 (Alarm setpoints for alarm 2) [5CH Operation data]
2D0153	      5.PB (Proportional band) [5CH Operation data]
2D0154	      5.TI (Integral time) [5CH Operation data]
2D0155	      5.TD (Derivative time) [5CH Operation data]
2D0156	      5.MR (Manual reset) [5CH Operation data]
2D0157	      5.HYS (Hysteresis) [5CH Operation data]
2D0158	      5.DR (Direct/reverse action switching) [5CH Operation data]
2D0160	      6.SP (Target setpoint) [5CH Operation data]
2D0161	      6.A1 (Alarm setpoints for alarm 1) [5CH Operation data]
2D0162	      6.A2 (Alarm setpoints for alarm 2) [5CH Operation data]
2D0163	      6.PB (Proportional band) [5CH Operation data]
2D0164	      6.TI (Integral time) [5CH Operation data]
2D0165	      6.TD (Derivative time) [5CH Operation data]
2D0166	      6.MR (Manual reset) [5CH Operation data]
2D0167	      6.HYS (Hysteresis) [5CH Operation data]
2D0168	      6.DR (Direct/reverse action switching) [5CH Operation data]
2D0170	      7.SP (Target setpoint) [5CH Operation data]
2D0171	      7.A1 (Alarm setpoints for alarm 1) [5CH Operation data]
2D0172	      7.A2 (Alarm setpoints for alarm 2) [5CH Operation data]
2D0173	      7.PB (Proportional band) [5CH Operation data]
2D0174	      7.TI (Integral time) [5CH Operation data]
2D0175	      7.TD (Derivative time) [5CH Operation data]
2D0176	      7.MR (Manual reset) [5CH Operation data]
2D0177	      7.HYS (Hysteresis) [5CH Operation data]
2D0178	      7.DR (Direct/reverse action switching) [5CH Operation data]
2D0180	      8.SP (Target setpoint) [5CH Operation data]
2D0181	      8.A1 (Alarm setpoints for alarm 1) [5CH Operation data]
2D0182	      8.A2 (Alarm setpoints for alarm 2) [5CH Operation data]
2D0183	      8.PB (Proportional band) [5CH Operation data]
2D0184	      8.TI (Integral time) [5CH Operation data]
2D0185	      8.TD (Derivative time) [5CH Operation data]
2D0186	      8.MR (Manual reset) [5CH Operation data]
2D0187	      8.HYS (Hysteresis) [5CH Operation data]
2D0188	      8.DR (Direct/reverse action switching) [5CH Operation data]
2D0210	      1.SP (Target setpoint) [6CH Operation data]
2D0211	      1.A1 (Alarm setpoints for alarm 1) [6CH Operation data]
2D0212	      1.A2 (Alarm setpoints for alarm 2) [6CH Operation data]
2D0213	      1.PB (Proportional band) [6CH Operation data]
2D0214	      1.TI (Integral time) [6CH Operation data]
2D0215	      1.TD (Derivative time) [6CH Operation data]
2D0216	      1.MR (Manual reset) [6CH Operation data]
2D0217	      1.HYS (Hysteresis) [6CH Operation data]
2D0218	      1.DR (Direct/reverse action switching) [6CH Operation data]
2D0220	      2.SP (Target setpoint) [6CH Operation data]
2D0221	      2.A1 (Alarm setpoints for alarm 1) [6CH Operation data]
2D0222	      2.A2 (Alarm setpoints for alarm 2) [6CH Operation data]
2D0223	      2.PB (Proportional band) [6CH Operation data]
2D0224	      2.TI (Integral time) [6CH Operation data]
2D0225	      2.TD (Derivative time) [6CH Operation data]
2D0226	      2.MR (Manual reset) [6CH Operation data]
2D0227	      2.HYS (Hysteresis) [6CH Operation data]
2D0228	      2.DR (Direct/reverse action switching) [6CH Operation data]
2D0230	      3.SP (Target setpoint) [6CH Operation data]
2D0231	      3.A1 (Alarm setpoints for alarm 1) [6CH Operation data]
2D0232	      3.A2 (Alarm setpoints for alarm 2) [6CH Operation data]
2D0233	      3.PB (Proportional band) [6CH Operation data]
2D0234	      3.TI (Integral time) [6CH Operation data]
2D0235	      3.TD (Derivative time) [6CH Operation data]
2D0236	      3.MR (Manual reset) [6CH Operation data]
2D0237	      3.HYS (Hysteresis) [6CH Operation data]
2D0238	      3.DR (Direct/reverse action switching) [6CH Operation data]
2D0240	      4.SP (Target setpoint) [6CH Operation data]
2D0241	      4.A1 (Alarm setpoints for alarm 1) [6CH Operation data]
2D0242	      4.A2 (Alarm setpoints for alarm 2) [6CH Operation data]
2D0243	      4.PB (Proportional band) [6CH Operation data]
2D0244	      4.TI (Integral time) [6CH Operation data]
2D0245	      4.TD (Derivative time) [6CH Operation data]
2D0246	      4.MR (Manual reset) [6CH Operation data]
2D0247	      4.HYS (Hysteresis) [6CH Operation data]
2D0248	      4.DR (Direct/reverse action switching) [6CH Operation data]
2D0250	      5.SP (Target setpoint) [6CH Operation data]
2D0251	      5.A1 (Alarm setpoints for alarm 1) [6CH Operation data]
2D0252	      5.A2 (Alarm setpoints for alarm 2) [6CH Operation data]
2D0253	      5.PB (Proportional band) [6CH Operation data]
2D0254	      5.TI (Integral time) [6CH Operation data]
2D0255	      5.TD (Derivative time) [6CH Operation data]
2D0256	      5.MR (Manual reset) [6CH Operation data]
2D0257	      5.HYS (Hysteresis) [6CH Operation data]
2D0258	      5.DR (Direct/reverse action switching) [6CH Operation data]
2D0260	      6.SP (Target setpoint) [6CH Operation data]
2D0261	      6.A1 (Alarm setpoints for alarm 1) [6CH Operation data]
2D0262	      6.A2 (Alarm setpoints for alarm 2) [6CH Operation data]
2D0263	      6.PB (Proportional band) [6CH Operation data]
2D0264	      6.TI (Integral time) [6CH Operation data]
2D0265	      6.TD (Derivative time) [6CH Operation data]
2D0266	      6.MR (Manual reset) [6CH Operation data]
2D0267	      6.HYS (Hysteresis) [6CH Operation data]
2D0268	      6.DR (Direct/reverse action switching) [6CH Operation data]
2D0270	      7.SP (Target setpoint) [6CH Operation data]
2D0271	      7.A1 (Alarm setpoints for alarm 1) [6CH Operation data]
2D0272	      7.A2 (Alarm setpoints for alarm 2) [6CH Operation data]
2D0273	      7.PB (Proportional band) [6CH Operation data]
2D0274	      7.TI (Integral time) [6CH Operation data]
2D0275	      7.TD (Derivative time) [6CH Operation data]
2D0276	      7.MR (Manual reset) [6CH Operation data]
2D0277	      7.HYS (Hysteresis) [6CH Operation data]
2D0278	      7.DR (Direct/reverse action switching) [6CH Operation data]
2D0280	      8.SP (Target setpoint) [6CH Operation data]
2D0281	      8.A1 (Alarm setpoints for alarm 1) [6CH Operation data]
2D0282	      8.A2 (Alarm setpoints for alarm 2) [6CH Operation data]
2D0283	      8.PB (Proportional band) [6CH Operation data]
2D0284	      8.TI (Integral time) [6CH Operation data]
2D0285	      8.TD (Derivative time) [6CH Operation data]
2D0286	      8.MR (Manual reset) [6CH Operation data]
2D0287	      8.HYS (Hysteresis) [6CH Operation data]
2D0288	      8.DR (Direct/reverse action switching) [6CH Operation data]
2D0310	      1.SP (Target setpoint) [7CH Operation data]
2D0311	      1.A1 (Alarm setpoints for alarm 1) [7CH Operation data]
2D0312	      1.A2 (Alarm setpoints for alarm 2) [7CH Operation data]
2D0313	      1.PB (Proportional band) [7CH Operation data]
2D0314	      1.TI (Integral time) [7CH Operation data]
2D0315	      1.TD (Derivative time) [7CH Operation data]
2D0316	      1.MR (Manual reset) [7CH Operation data]
2D0317	      1.HYS (Hysteresis) [7CH Operation data]
2D0318	      1.DR (Direct/reverse action switching) [7CH Operation data]
2D0320	      2.SP (Target setpoint) [7CH Operation data]
2D0321	      2.A1 (Alarm setpoints for alarm 1) [7CH Operation data]
2D0322	      2.A2 (Alarm setpoints for alarm 2) [7CH Operation data]
2D0323	      2.PB (Proportional band) [7CH Operation data]
2D0324	      2.TI (Integral time) [7CH Operation data]
2D0325	      2.TD (Derivative time) [7CH Operation data]
2D0326	      2.MR (Manual reset) [7CH Operation data]
2D0327	      2.HYS (Hysteresis) [7CH Operation data]
2D0328	      2.DR (Direct/reverse action switching) [7CH Operation data]
2D0330	      3.SP (Target setpoint) [7CH Operation data]
2D0331	      3.A1 (Alarm setpoints for alarm 1) [7CH Operation data]
2D0332	      3.A2 (Alarm setpoints for alarm 2) [7CH Operation data]
2D0333	      3.PB (Proportional band) [7CH Operation data]
2D0334	      3.TI (Integral time) [7CH Operation data]
2D0335	      3.TD (Derivative time) [7CH Operation data]
2D0336	      3.MR (Manual reset) [7CH Operation data]
2D0337	      3.HYS (Hysteresis) [7CH Operation data]
2D0338	      3.DR (Direct/reverse action switching) [7CH Operation data]
2D0340	      4.SP (Target setpoint) [7CH Operation data]
2D0341	      4.A1 (Alarm setpoints for alarm 1) [7CH Operation data]
2D0342	      4.A2 (Alarm setpoints for alarm 2) [7CH Operation data]
2D0343	      4.PB (Proportional band) [7CH Operation data]
2D0344	      4.TI (Integral time) [7CH Operation data]
2D0345	      4.TD (Derivative time) [7CH Operation data]
2D0346	      4.MR (Manual reset) [7CH Operation data]
2D0347	      4.HYS (Hysteresis) [7CH Operation data]
2D0348	      4.DR (Direct/reverse action switching) [7CH Operation data]
2D0350	      5.SP (Target setpoint) [7CH Operation data]
2D0351	      5.A1 (Alarm setpoints for alarm 1) [7CH Operation data]
2D0352	      5.A2 (Alarm setpoints for alarm 2) [7CH Operation data]
2D0353	      5.PB (Proportional band) [7CH Operation data]
2D0354	      5.TI (Integral time) [7CH Operation data]
2D0355	      5.TD (Derivative time) [7CH Operation data]
2D0356	      5.MR (Manual reset) [7CH Operation data]
2D0357	      5.HYS (Hysteresis) [7CH Operation data]
2D0358	      5.DR (Direct/reverse action switching) [7CH Operation data]
2D0360	      6.SP (Target setpoint) [7CH Operation data]
2D0361	      6.A1 (Alarm setpoints for alarm 1) [7CH Operation data]
2D0362	      6.A2 (Alarm setpoints for alarm 2) [7CH Operation data]
2D0363	      6.PB (Proportional band) [7CH Operation data]
2D0364	      6.TI (Integral time) [7CH Operation data]
2D0365	      6.TD (Derivative time) [7CH Operation data]
2D0366	      6.MR (Manual reset) [7CH Operation data]
2D0367	      6.HYS (Hysteresis) [7CH Operation data]
2D0368	      6.DR (Direct/reverse action switching) [7CH Operation data]
2D0370	      7.SP (Target setpoint) [7CH Operation data]
2D0371	      7.A1 (Alarm setpoints for alarm 1) [7CH Operation data]
2D0372	      7.A2 (Alarm setpoints for alarm 2) [7CH Operation data]
2D0373	      7.PB (Proportional band) [7CH Operation data]
2D0374	      7.TI (Integral time) [7CH Operation data]
2D0375	      7.TD (Derivative time) [7CH Operation data]
2D0376	      7.MR (Manual reset) [7CH Operation data]
2D0377	      7.HYS (Hysteresis) [7CH Operation data]
2D0378	      7.DR (Direct/reverse action switching) [7CH Operation data]
2D0380	      8.SP (Target setpoint) [7CH Operation data]
2D0381	      8.A1 (Alarm setpoints for alarm 1) [7CH Operation data]
2D0382	      8.A2 (Alarm setpoints for alarm 2) [7CH Operation data]
2D0383	      8.PB (Proportional band) [7CH Operation data]
2D0384	      8.TI (Integral time) [7CH Operation data]
2D0385	      8.TD (Derivative time) [7CH Operation data]
2D0386	      8.MR (Manual reset) [7CH Operation data]
2D0387	      8.HYS (Hysteresis) [7CH Operation data]
2D0388	      8.DR (Direct/reverse action switching) [7CH Operation data]
2D0410	      1.SP (Target setpoint) [8CH Operation data]
2D0411	      1.A1 (Alarm setpoints for alarm 1) [8CH Operation data]
2D0412	      1.A2 (Alarm setpoints for alarm 2) [8CH Operation data]
2D0413	      1.PB (Proportional band) [8CH Operation data]
2D0414	      1.TI (Integral time) [8CH Operation data]
2D0415	      1.TD (Derivative time) [8CH Operation data]
2D0416	      1.MR (Manual reset) [8CH Operation data]
2D0417	      1.HYS (Hysteresis) [8CH Operation data]
2D0418	      1.DR (Direct/reverse action switching) [8CH Operation data]
2D0420	      2.SP (Target setpoint) [8CH Operation data]
2D0421	      2.A1 (Alarm setpoints for alarm 1) [8CH Operation data]
2D0422	      2.A2 (Alarm setpoints for alarm 2) [8CH Operation data]
2D0423	      2.PB (Proportional band) [8CH Operation data]
2D0424	      2.TI (Integral time) [8CH Operation data]
2D0425	      2.TD (Derivative time) [8CH Operation data]
2D0426	      2.MR (Manual reset) [8CH Operation data]
2D0427	      2.HYS (Hysteresis) [8CH Operation data]
2D0428	      2.DR (Direct/reverse action switching) [8CH Operation data]
2D0430	      3.SP (Target setpoint) [8CH Operation data]
2D0431	      3.A1 (Alarm setpoints for alarm 1) [8CH Operation data]
2D0432	      3.A2 (Alarm setpoints for alarm 2) [8CH Operation data]
2D0433	      3.PB (Proportional band) [8CH Operation data]
2D0434	      3.TI (Integral time) [8CH Operation data]
2D0435	      3.TD (Derivative time) [8CH Operation data]
2D0436	      3.MR (Manual reset) [8CH Operation data]
2D0437	      3.HYS (Hysteresis) [8CH Operation data]
2D0438	      3.DR (Direct/reverse action switching) [8CH Operation data]
2D0440	      4.SP (Target setpoint) [8CH Operation data]
2D0441	      4.A1 (Alarm setpoints for alarm 1) [8CH Operation data]
2D0442	      4.A2 (Alarm setpoints for alarm 2) [8CH Operation data]
2D0443	      4.PB (Proportional band) [8CH Operation data]
2D0444	      4.TI (Integral time) [8CH Operation data]
2D0445	      4.TD (Derivative time) [8CH Operation data]
2D0446	      4.MR (Manual reset) [8CH Operation data]
2D0447	      4.HYS (Hysteresis) [8CH Operation data]
2D0448	      4.DR (Direct/reverse action switching) [8CH Operation data]
2D0450	      5.SP (Target setpoint) [8CH Operation data]
2D0451	      5.A1 (Alarm setpoints for alarm 1) [8CH Operation data]
2D0452	      5.A2 (Alarm setpoints for alarm 2) [8CH Operation data]
2D0453	      5.PB (Proportional band) [8CH Operation data]
2D0454	      5.TI (Integral time) [8CH Operation data]
2D0455	      5.TD (Derivative time) [8CH Operation data]
2D0456	      5.MR (Manual reset) [8CH Operation data]
2D0457	      5.HYS (Hysteresis) [8CH Operation data]
2D0458	      5.DR (Direct/reverse action switching) [8CH Operation data]
2D0460	      6.SP (Target setpoint) [8CH Operation data]
2D0461	      6.A1 (Alarm setpoints for alarm 1) [8CH Operation data]
2D0462	      6.A2 (Alarm setpoints for alarm 2) [8CH Operation data]
2D0463	      6.PB (Proportional band) [8CH Operation data]
2D0464	      6.TI (Integral time) [8CH Operation data]
2D0465	      6.TD (Derivative time) [8CH Operation data]
2D0466	      6.MR (Manual reset) [8CH Operation data]
2D0467	      6.HYS (Hysteresis) [8CH Operation data]
2D0468	      6.DR (Direct/reverse action switching) [8CH Operation data]
2D0470	      7.SP (Target setpoint) [8CH Operation data]
2D0471	      7.A1 (Alarm setpoints for alarm 1) [8CH Operation data]
2D0472	      7.A2 (Alarm setpoints for alarm 2) [8CH Operation data]
2D0473	      7.PB (Proportional band) [8CH Operation data]
2D0474	      7.TI (Integral time) [8CH Operation data]
2D0475	      7.TD (Derivative time) [8CH Operation data]
2D0476	      7.MR (Manual reset) [8CH Operation data]
2D0477	      7.HYS (Hysteresis) [8CH Operation data]
2D0478	      7.DR (Direct/reverse action switching) [8CH Operation data]
2D0480	      8.SP (Target setpoint) [8CH Operation data]
2D0481	      8.A1 (Alarm setpoints for alarm 1) [8CH Operation data]
2D0482	      8.A2 (Alarm setpoints for alarm 2) [8CH Operation data]
2D0483	      8.PB (Proportional band) [8CH Operation data]
2D0484	      8.TI (Integral time) [8CH Operation data]
2D0485	      8.TD (Derivative time) [8CH Operation data]
2D0486	      8.MR (Manual reset) [8CH Operation data]
2D0487	      8.HYS (Hysteresis) [8CH Operation data]
2D0488	      8.DR (Direct/reverse action switching) [8CH Operation data]
2D0510	      1.SP (Target setpoint) [All CH5~CH8 setting]
2D0511	      1.A1 (Alarm setpoints for alarm 1) [All CH5~CH8 setting]
2D0512	      1.A2 (Alarm setpoints for alarm 2) [All CH5~CH8 setting]
2D0513	      1.PB (Proportional band) [All CH5~CH8 setting]
2D0514	      1.TI (Integral time) [All CH5~CH8 setting]
2D0515	      1.TD (Derivative time) [All CH5~CH8 setting]
2D0516	      1.MR (Manual reset) [All CH5~CH8 setting]
2D0517	      1.HYS (Hysteresis) [All CH5~CH8 setting]
2D0518	      1.DR (Direct/reverse action switching) [All CH5~CH8 setting]
2D0520	      2.SP (Target setpoint) [All CH5~CH8 setting]
2D0521	      2.A1 (Alarm setpoints for alarm 1) [All CH5~CH8 setting]
2D0522	      2.A2 (Alarm setpoints for alarm 2) [All CH5~CH8 setting]
2D0523	      2.PB (Proportional band) [All CH5~CH8 setting]
2D0524	      2.TI (Integral time) [All CH5~CH8 setting]
2D0525	      2.TD (Derivative time) [All CH5~CH8 setting]
2D0526	      2.MR (Manual reset) [All CH5~CH8 setting]
2D0527	      2.HYS (Hysteresis) [All CH5~CH8 setting]
2D0528	      2.DR (Direct/reverse action switching) [All CH5~CH8 setting]
2D0530	      3.SP (Target setpoint) [All CH5~CH8 setting]
2D0531	      3.A1 (Alarm setpoints for alarm 1) [All CH5~CH8 setting]
2D0532	      3.A2 (Alarm setpoints for alarm 2) [All CH5~CH8 setting]
2D0533	      3.PB (Proportional band) [All CH5~CH8 setting]
2D0534	      3.TI (Integral time) [All CH5~CH8 setting]
2D0535	      3.TD (Derivative time) [All CH5~CH8 setting]
2D0536	      3.MR (Manual reset) [All CH5~CH8 setting]
2D0537	      3.HYS (Hysteresis) [All CH5~CH8 setting]
2D0538	      3.DR (Direct/reverse action switching) [All CH5~CH8 setting]
2D0540	      4.SP (Target setpoint) [All CH5~CH8 setting]
2D0541	      4.A1 (Alarm setpoints for alarm 1) [All CH5~CH8 setting]
2D0542	      4.A2 (Alarm setpoints for alarm 2) [All CH5~CH8 setting]
2D0543	      4.PB (Proportional band) [All CH5~CH8 setting]
2D0544	      4.TI (Integral time) [All CH5~CH8 setting]
2D0545	      4.TD (Derivative time) [All CH5~CH8 setting]
2D0546	      4.MR (Manual reset) [All CH5~CH8 setting]
2D0547	      4.HYS (Hysteresis) [All CH5~CH8 setting]
2D0548	      4.DR (Direct/reverse action switching) [All CH5~CH8 setting]
2D0550	      5.SP (Target setpoint) [All CH5~CH8 setting]
2D0551	      5.A1 (Alarm setpoints for alarm 1) [All CH5~CH8 setting]
2D0552	      5.A2 (Alarm setpoints for alarm 2) [All CH5~CH8 setting]
2D0553	      5.PB (Proportional band) [All CH5~CH8 setting]
2D0554	      5.TI (Integral time) [All CH5~CH8 setting]
2D0555	      5.TD (Derivative time) [All CH5~CH8 setting]
2D0556	      5.MR (Manual reset) [All CH5~CH8 setting]
2D0557	      5.HYS (Hysteresis) [All CH5~CH8 setting]
2D0558	      5.DR (Direct/reverse action switching) [All CH5~CH8 setting]
2D0560	      6.SP (Target setpoint) [All CH5~CH8 setting]
2D0561	      6.A1 (Alarm setpoints for alarm 1) [All CH5~CH8 setting]
2D0562	      6.A2 (Alarm setpoints for alarm 2) [All CH5~CH8 setting]
2D0563	      6.PB (Proportional band) [All CH5~CH8 setting]
2D0564	      6.TI (Integral time) [All CH5~CH8 setting]
2D0565	      6.TD (Derivative time) [All CH5~CH8 setting]
2D0566	      6.MR (Manual reset) [All CH5~CH8 setting]
2D0567	      6.HYS (Hysteresis) [All CH5~CH8 setting]
2D0568	      6.DR (Direct/reverse action switching) [All CH5~CH8 setting]
2D0570	      7.SP (Target setpoint) [All CH5~CH8 setting]
2D0571	      7.A1 (Alarm setpoints for alarm 1) [All CH5~CH8 setting]
2D0572	      7.A2 (Alarm setpoints for alarm 2) [All CH5~CH8 setting]
2D0573	      7.PB (Proportional band) [All CH5~CH8 setting]
2D0574	      7.TI (Integral time) [All CH5~CH8 setting]
2D0575	      7.TD (Derivative time) [All CH5~CH8 setting]
2D0576	      7.MR (Manual reset) [All CH5~CH8 setting]
2D0577	      7.HYS (Hysteresis) [All CH5~CH8 setting]
2D0578	      7.DR (Direct/reverse action switching) [All CH5~CH8 setting]
2D0580	      8.SP (Target setpoint) [All CH5~CH8 setting]
2D0581	      8.A1 (Alarm setpoints for alarm 1) [All CH5~CH8 setting]
2D0582	      8.A2 (Alarm setpoints for alarm 2) [All CH5~CH8 setting]
2D0583	      8.PB (Proportional band) [All CH5~CH8 setting]
2D0584	      8.TI (Integral time) [All CH5~CH8 setting]
2D0585	      8.TD (Derivative time) [All CH5~CH8 setting]
2D0586	      8.MR (Manual reset) [All CH5~CH8 setting]
2D0587	      8.HYS (Hysteresis) [All CH5~CH8 setting]
2D0588	      8.DR (Direct/reverse action switching) [All CH5~CH8 setting]
2D0600	      SC (SUPER function selection) [5CH Setup data]
2D0601	      AT (Auto-tuning selection) [5CH Setup data]
2D0602	      SP.UP (Setpoint ramp-up rate setting) [5CH Setup data]
2D0603	      SP.DN (Setpoint ramp-down rate setting) [5CH Setup data]
2D0604	      SP.R (Ramp-rate time unit setting) [5CH Setup data]
2D0605	      FL (Filter) [5CH Setup data]
2D0606	      BS (Input compensation bias) [5CH Setup data]
2D0607	      A/M (AUTO/MAN modes) [5CH Setup data]
2D0608	      R/S (STOP/RUN modes) [5CH Setup data]
2D0609	      MANOUT (Manual output value) [5CH Setup data]
2D0610	      PROUT (Preset output value) [5CH Setup data]
2D0611	      SPNO (Group SP number) [5CH Setup data]
2D0612	      HB (Heater current measurement) [5CH Setup data]
2D0613	      AL1 (Alarm-1 type) [5CH Setup data]
2D0614	      AL2 (Alarm-2 type) [5CH Setup data]
2D0615	      HY1 (Alarm-1 hysteresis) [5CH Setup data]
2D0616	      HY2 (Alarm-2 hysteresis) [5CH Setup data]
2D0617	      CT (Cycle time) [5CH Setup data]
2D0618	      OH (Upper limit of output) [5CH Setup data]
2D0619	      OL (Lower limit of output) [5CH Setup data]
2D0620	      RST (Restart mode) [5CH Setup data]
2D0621	      ORBND (ON/OFF rate detection width) [5CH Setup data]
2D0622	      ORHI (ON/OFF rate upper limit) [5CH Setup data]
2D0623	      ORLO (ON/OFF rate lower limit) [5CH Setup data]
2D0624	      USE (use/unuse) [5CH Setup data]
2D0625	      A3 (Alarm-3 setpoint) [5CH Setup data]
2D0626	      AL3 (Alarm-3 type) [5CH Setup data]
2D0627	      HY3 (Alarm-3 hysteresis) [5CH Setup data]
2D0650	      PD (Decimal point position) [5CH Setup data]
2D0651	      RH (Instrument range upper limit) [5CH Setup data]
2D0652	      RL (Instrument range lower limit) [5CH Setup data]
2D0653	      ARSL (ARM action mode) [5CH Setup data]
2D0654	      MD (Channel action mode) [5CH Setup data]
2D0700	      SC (SUPER function selection) [6CH Setup data]
2D0701	      AT (Auto-tuning selection) [6CH Setup data]
2D0702	      SP.UP (Setpoint ramp-up rate setting) [6CH Setup data]
2D0703	      SP.DN (Setpoint ramp-down rate setting) [6CH Setup data]
2D0704	      SP.R (Rate time unit) [6CH Setup data]
2D0705	      FL (Filter) [6CH Setup data]
2D0706	      BS (Input compensation bias) [6CH Setup data]
2D0707	      A/M (AUTO/MAN modes) [6CH Setup data]
2D0708	      R/S (STOP/RUN modes) [6CH Setup data]
2D0709	      MANOUT (ManualOutput value) [6CH Setup data]
2D0710	      PROUT (PresetOutput value) [6CH Setup data]
2D0711	      SPNO (Group SP number) [6CH Setup data]
2D0712	      HB (Heater current measurement) [6CH Setup data]
2D0713	      AL1 (Alarm-1 type) [6CH Setup data]
2D0714	      AL2 (Alarm-2 type) [6CH Setup data]
2D0715	      HY1 (Alarm-1 hysteresis) [6CH Setup data]
2D0716	      HY2 (Alarm-2 hysteresis) [6CH Setup data]
2D0717	      CT (Cycle time) [6CH Setup data]
2D0718	      OH (Upper limit of output) [6CH Setup data]
2D0719	      OL (Lower limit of output) [6CH Setup data]
2D0720	      RST (Restart mode) [6CH Setup data]
2D0721	      ORBND (ON/OFF rate detection width) [6CH Setup data]
2D0722	      ORHI (ON/OFF rate upper limit) [6CH Setup data]
2D0723	      ORLO (ON/OFF rate lower limit) [6CH Setup data]
2D0724	      USE (use/unuse) [6CH Setup data]
2D0725	      A3 (Alarm-3 setpoint) [6CH Setup data]
2D0726	      AL3 (Alarm-3 type) [6CH Setup data]
2D0727	      HY3 (Alarm-3 hysteresis) [6CH Setup data]
2D0750	      PD (Decimal point position) [6CH Setup data]
2D0751	      RH (Instrument range upper limit) [6CH Setup data]
2D0752	      RL (Instrument range lower limit) [6CH Setup data]
2D0753	      ARSL (ARM action mode) [6CH Setup data]
2D0754	      MD (Channel action mode) [6CH Setup data]
2D0800	      SC (SUPER function selection) [7CH Setup data]
2D0801	      AT (Auto-tuning selection) [7CH Setup data]
2D0802	      SP.UP (Setpoint ramp-up rate setting) [7CH Setup data]
2D0803	      SP.DN (Setpoint ramp-down rate setting) [7CH Setup data]
2D0804	      SP.R (Rate time unit) [7CH Setup data]
2D0805	      FL (Filter) [7CH Setup data]
2D0806	      BS (Input compensation bias) [7CH Setup data]
2D0807	      A/M (AUTO/MAN modes) [7CH Setup data]
2D0808	      R/S (STOP/RUN modes) [7CH Setup data]
2D0809	      MANOUT (ManualOutput value) [7CH Setup data]
2D0810	      PROUT (PresetOutput value) [7CH Setup data]
2D0811	      SPNO (Group SP number) [7CH Setup data]
2D0812	      HB (Heater current measurement) [7CH Setup data]
2D0813	      AL1 (Alarm-1 type) [7CH Setup data]
2D0814	      AL2 (Alarm-2 type) [7CH Setup data]
2D0815	      HY1 (Alarm-1 hysteresis) [7CH Setup data]
2D0816	      HY2 (Alarm-2 hysteresis) [7CH Setup data]
2D0817	      CT (Cycle time) [7CH Setup data]
2D0818	      OH (Upper limit of output) [7CH Setup data]
2D0819	      OL (Lower limit of output) [7CH Setup data]
2D0820	      RST (Restart mode) [7CH Setup data]
2D0821	      ORBND (ON/OFF rate detection width) [7CH Setup data]
2D0822	      ORHI (ON/OFF rate upper limit) [7CH Setup data]
2D0823	      ORLO (ON/OFF rate lower limit) [7CH Setup data]
2D0824	      USE (use/unuse) [7CH Setup data]
2D0825	      A3 (Alarm-3 setpoint) [7CH Setup data]
2D0826	      AL3 (Alarm-3 type) [7CH Setup data]
2D0827	      HY3 (Alarm-3 hysteresis) [7CH Setup data]
2D0850	      PD (Decimal point position) [7CH Setup data]
2D0851	      RH (Instrument range upper limit) [7CH Setup data]
2D0852	      RL (Instrument range lower limit) [7CH Setup data]
2D0853	      ARSL (ARM action mode) [7CH Setup data]
2D0854	      MD (Channel action mode) [7CH Setup data]
2D0900	      SC (SUPER function selection) [8CH Setup data]
2D0901	      AT (Auto-tuning selection) [8CH Setup data]
2D0902	      SP.UP (Setpoint ramp-up rate setting) [8CH Setup data]
2D0903	      SP.DN (Setpoint ramp-down rate setting) [8CH Setup data]
2D0904	      SP.R (Rate time unit) [8CH Setup data]
2D0905	      FL (Filter) [8CH Setup data]
2D0906	      BS (Input compensation bias) [8CH Setup data]
2D0907	      A/M (AUTO/MAN modes) [8CH Setup data]
2D0908	      R/S (STOP/RUN modes) [8CH Setup data]
2D0909	      MANOUT (Manual output value) [8CH Setup data]
2D0910	      PROUT (Preset output value) [8CH Setup data]
2D0911	      SPNO (Group SP number) [8CH Setup data]
2D0912	      HB (Heater current measurement) [8CH Setup data]
2D0913	      AL1 (Alarm-1 type) [8CH Setup data]
2D0914	      AL2 (Alarm-2 type) [8CH Setup data]
2D0915	      HY1 (Alarm-1 hysteresis) [8CH Setup data]
2D0916	      HY2 (Alarm-2 hysteresis) [8CH Setup data]
2D0917	      CT (Cycle time) [8CH Setup data]
2D0918	      OH (Upper limit of output) [8CH Setup data]
2D0919	      OL (Lower limit of output) [8CH Setup data]
2D0920	      RST (Restart mode) [8CH Setup data]
2D0921	      ORBND (ON/OFF rate detection width) [8CH Setup data]
2D0922	      ORHI (ON/OFF rate upper limit) [8CH Setup data]
2D0923	      ORLO (ON/OFF rate lower limit) [8CH Setup data]
2D0924	      USE (use/unuse) [8CH Setup data]
2D0925	      A3 (Alarm-3 setpoint) [8CH Setup data]
2D0926	      AL3 (Alarm-3 type) [8CH Setup data]
2D0927	      HY3 (Alarm-3 hysteresis) [8CH Setup data]
2D0950	      PD (Decimal point position) [8CH Setup data]
2D0951	      RH (Instrument range upper limit) [8CH Setup data]
2D0952	      RL (Instrument range lower limit) [8CH Setup data]
2D0953	      ARSL (ARM action mode) [8CH Setup data]
2D0954	      MD (Channel action mode) [8CH Setup data]
2D0955	      STEUP (Setup mode) [All CH Setup data]
2D0956	      IN (Input type) [All CH Setup data]
2D1000	      SC (SUPER function selection) [All CH5~CH8 setting]
2D1001	      AT (Auto-tuning selection) [All CH5~CH8 setting]
2D1002	      SP.UP (Setpoint ramp-up rate setting) [All CH5~CH8 setting]
2D1003	      SP.DN (Setpoint ramp-down rate setting) [All CH5~CH8 setting]
2D1004	      SP.R (Rate time unit) [All CH5~CH8 setting]
2D1005	      FL (Filter) [All CH5~CH8 setting]
2D1006	      BS (Input compensation bias) [All CH5~CH8 setting]
2D1007	      A/M (AUTO/MAN modes) [All CH5~CH8 setting]
2D1008	      R/S (STOP/RUN modes) [All CH5~CH8 setting]
2D1009	      MANOUT (ManualOutput value) [All CH5~CH8 setting]
2D1010	      PROUT (PresetOutput value) [All CH5~CH8 setting]
2D1011	      SPNO (Group SP number) [All CH5~CH8 setting]
2D1012	      HB (Heater current measurement) [All CH5~CH8 setting]
2D1013	      AL1 (Alarm-1 type) [All CH5~CH8 setting]
2D1014	      AL2 (Alarm-2 type) [All CH5~CH8 setting]
2D1015	      HY1 (Alarm-1 hysteresis) [All CH5~CH8 setting]
2D1016	      HY2 (Alarm-2 hysteresis) [All CH5~CH8 setting]
2D1017	      CT (Cycle time) [All CH5~CH8 setting]
2D1018	      OH (Upper limit of output) [All CH5~CH8 setting]
2D1019	      OL (Lower limit of output) [All CH5~CH8 setting]
2D1020	      RST (Restart mode) [All CH5~CH8 setting]
2D1021	      ORBND (ON/OFF rate detection width) [All CH5~CH8 setting]
2D1022	      ORHI (ON/OFF rate upper limit) [All CH5~CH8 setting]
2D1023	      ORLO (ON/OFF rate lower limit) [All CH5~CH8 setting]
2D1024	      USE (use/unuse) [All CH5~CH8 setting]
[D-SigDataEnd-2]-B

[I-SigData]
[I-SigDataEnd]

[I-SigData-2]
[I-SigDataEnd-2]

[I-SigData]-B
1I0001	+1
1I0002	+10
1I0003	+100
1I0004	+1000
1I0005	-1
1I0006	-10
1I0007	-100
1I0008	-1000
1I0101	AL1 [1CH Status]
1I0105	AL2 [1CH Status]
1I0109	H.B [1CH Status]
1I0117	BOUT [1CH Status]
1I0121	+OVER [1CH Status]
1I0125	-OVER [1CH Status]
1I0133	ADCERR [1CH Status]
1I0137	RJCERR [1CH Status]
1I0141	H Shield [1CH Status]
1I0149	SYSERR [1CH Status]
1I0153	CALERR [1CH Status]
1I0157	PARAERR [1CH Status]
1I0201	AL1 [2CH Status]
1I0205	AL2 [2CH Status]
1I0209	H.B [2CH Status]
1I0217	BOUT [2CH Status]
1I0221	+OVER [2CH Status]
1I0225	-OVER [2CH Status]
1I0233	ADCERR [2CH Status]
1I0237	RJCERR [2CH Status]
1I0241	H Shield [2CH Status]
1I0249	SYSERR [2CH Status]
1I0253	CALERR [2CH Status]
1I0257	PARAERR [2CH Status]
1I0301	AL1 [3CH Status]
1I0305	AL2 [3CH Status]
1I0309	H.B [3CH Status]
1I0317	BOUT [3CH Status]
1I0321	+OVER [3CH Status]
1I0325	-OVER [3CH Status]
1I0333	ADCERR [3CH Status]
1I0337	RJCERR [3CH Status]
1I0341	H Shield [3CH Status]
1I0349	SYSERR [3CH Status]
1I0353	CALERR [3CH Status]
1I0357	PARAERR [3CH Status]
1I0401	AL1 [4CH Status]
1I0405	AL2 [4CH Status]
1I0409	H.B [4CH Status]
1I0417	BOUT [4CH Status]
1I0421	+OVER [4CH Status]
1I0425	-OVER [4CH Status]
1I0433	ADCERR [4CH Status]
1I0437	RJCERR [4CH Status]
1I0441	H Shield [4CH Status]
1I0449	SYSERR [4CH Status]
1I0453	CALERR [4CH Status]
1I0457	PARAERR [4CH Status]
1I0501	A/M [1CH Mode]
1I0505	R/S [1CH Mode]
1I0513	AT [1CH Mode]
1I0601	A/M [2CH Mode]
1I0605	R/S [2CH Mode]
1I0613	AT [2CH Mode]
1I0701	A/M [3CH Mode]
1I0705	R/S [3CH Mode]
1I0713	AT [3CH Mode]
1I0801	A/M [4CH Mode]
1I0805	R/S [4CH Mode]
1I0813	AT [4CH Mode]
1I0899	TIMING [4CH Mode]
[I-SigDataEnd]-B

[I-SigData-2]-B
2I0001	+1
2I0002	+10
2I0003	+100
2I0004	+1000
2I0005	-1
2I0006	-10
2I0007	-100
2I0008	-1000
2I0101	AL1 [5CH Status]
2I0105	AL2 [5CH Status]
2I0109	H.B [5CH Status]
2I0117	BOUT [5CH Status]
2I0121	+OVER [5CH Status]
2I0125	-OVER [5CH Status]
2I0133	ADCERR [5CH Status]
2I0137	RJCERR [5CH Status]
2I0141	H Shield [5CH Status]
2I0149	SYSERR [5CH Status]
2I0153	CALERR [5CH Status]
2I0157	PARAERR [5CH Status]
2I0201	AL1 [6CH Status]
2I0205	AL2 [6CH Status]
2I0209	H.B [6CH Status]
2I0217	BOUT [6CH Status]
2I0221	+OVER [6CH Status]
2I0225	-OVER [6CH Status]
2I0233	ADCERR [6CH Status]
2I0237	RJCERR [6CH Status]
2I0241	H Shield [6CH Status]
2I0249	SYSERR [6CH Status]
2I0253	CALERR [6CH Status]
2I0257	PARAERR [6CH Status]
2I0301	AL1 [7CH Status]
2I0305	AL2 [7CH Status]
2I0309	H.B [7CH Status]
2I0317	BOUT [7CH Status]
2I0321	+OVER [7CH Status]
2I0325	-OVER [7CH Status]
2I0333	ADCERR [7CH Status]
2I0337	RJCERR [7CH Status]
2I0341	H Shield [7CH Status]
2I0349	SYSERR [7CH Status]
2I0353	CALERR [7CH Status]
2I0357	PARAERR [7CH Status]
2I0401	AL1 [8CH Status]
2I0405	AL2 [8CH Status]
2I0409	H.B [8CH Status]
2I0417	BOUT [8CH Status]
2I0421	+OVER [8CH Status]
2I0425	-OVER [8CH Status]
2I0433	ADCERR [8CH Status]
2I0437	RJCERR [8CH Status]
2I0441	H Shield [8CH Status]
2I0449	SYSERR [8CH Status]
2I0453	CALERR [8CH Status]
2I0457	PARAERR [8CH Status]
2I0501	A/M [5CH Mode]
2I0505	R/S [5CH Mode]
2I0513	AT [5CH Mode]
2I0601	A/M [6CH Mode]
2I0605	R/S [6CH Mode]
2I0613	AT [6CH Mode]
2I0701	A/M [7CH Mode]
2I0705	R/S [7CH Mode]
2I0713	AT [7CH Mode]
2I0801	A/M [8CH Mode]
2I0805	R/S [8CH Mode]
2I0813	AT [8CH Mode]
2I0899	TIMING [8CH Mode]
[I-SigDataEnd-2]-B