﻿Name=PLC1
CMQV
MaxSigCnt=216
DataFormat=Decimal

[SigData]
01001	Gas type RAM
01002	Full- scale flow rate RAM
01003	Decimal point position of instantaneous flow rate RAM  
01004	Decimal point position of integrated flow rate RAM   
01005	Instantaneous flow rate unit RAM
01006	Integrated flow rate unit RAM
01201	Alarm status bit RAM
01201.0	Deviation lower limit alarm of instantaneous flow rate (AL01) RAM
01201.1	Deviation upper limit alarm of instantaneous flow rate (AL02) RAM
01201.2	Valve amperage lower limit alarm (AL11) RAM
01201.3	Valve amperage upper limit alarm (AL12) RAM
01201.4	Sensor error (common to AL81, AL82 and AL83) RAM
01201.5	Input / output adjustment data error (AL91) RAM
01201.6	Sensor calibration data error (AL92) RAM
01201.7	User setup data error (AL93) RAM
01201.8	Valve overheat prevention limit operation (AL71) RAM
01201.9	Sensor error 1 (AL81) RAM
01201.A	Sensor error 2 (AL82) RAM
01201.B	Sensor error 3 (AL83) RAM
01202	Event status bit RAM
01202.0	Event output 1 status RAM
01202.1	Event output 2 status RAM
01202.3	External contact 1 input status RAM
01202.4	External contact 2 input status RAM
01202.5	External contact 3 input status RAM
01202.6	External 3-stage switching input status 1 (0V input) RAM
01202.7	External 3-stage switching input status 2 (5V input) RAM
01203	Control status bit RAM
01203.0	OK lamp (PV control status)  0: Light-out 1: Lighting (Instantaneous PV OK) RAM
01203.1	Slow start operation 0: Normal operation 1: Slow start operation RAM 
01203.2	Digital setting / Analog setting 0: Digital setting 1: Analog setting RAM 
01203.3	Totalizing count status 0: Totalized flow PV < Totalized flow event SP 1: Totalized flow PV > or = Totalized flow event SP RAM 
01203.4	SP ramp control function 0: Function disabled 1: SP ramp control enabled RAM 
01204	Operation mode RAM
01205	Instantaneous SP No. in use RAM
01206	Instantaneous SP value in use RAM
01207	Instantaneous PV value RAM
01208	Valve actuation current RAM
01401	Flow set value SP-0 RAM 
01402	Flow set value SP-1 RAM
01403	Flow set value SP-2 RAM
01404	Flow set value SP-3 RAM
01405	Flow set value SP-4 RAM
01406	Flow set value SP-5 RAM
01407	Flow set value SP-6 RAM
01408	Flow set value SP-7 RAM 
01601	Totalized flow event setting lower 4 digits RAM
01602	Totalized flow event setting upper 4 digits RAM
01603	Totalized flow lower 4 digits RAM
01604	Totalized flow upper 4 digits RAM 
02001	Key lock Run RAM
02002	RUN key operation selection and operation mode selection when power turned ON RAM
02003	Flow rate setup method (SP setup method selection) RAM
02004	Number of flow set value selection (number of SPs selection) RAM
02005	Input range selection of analog setup (analog SP input range selection) RAM
02006	Analog output type and range selection (analog PV output range selection) RAM
02007	Event 1 output type assignment RAM
02008	Event 2 output type assignment RAM
02009	External 3-stage switching function assignment RAM
02010	External contact input 1 function assignment RAM  
02011	External contact input 2 function assignment RAM
02012	External contact input 3 function assignment RAM
02013	Automatic valve shut-off when the totalized flow event occurs RAM
02014	On/off of totalized flow reset function at start of control RAM
02015	Flow rate alarm setup type RAM
02016	Operation selection at alarm occurrence RAM
02017	Slow start setup RAM
02018	Gas type selection 1 RAM
02019	Flow rate display unit selection(reference conditions) RAM
02020	Valve amperage alarm setup type selection RAM
02021	Direct setup function ON/OFF RAM
02022	Control dead zone setting RAM
02023	PV filter (process for filtering of instantaneous flow rate) RAM
02024	Flow rate range setup 1 RAM
02025	Flow rate range setup 2 RAM
02026	Gas type selection 2 RAM
02027	SP ramp control function RAM
02028	Analog scaling function RAM
02029	Forced PV (instantaneous flow rate) zero function RAM
02030	Station address setting RAM
02031	Transmission speed selection RAM
02032	Data format selection RAM
02035	SP limit function RAM
02036	Operational differential pressure setting (control optimization) RAM
02037	Flow rate display unit change function RAM
02038	PV (instantaneous flow rate) display decimal point position change function RAM 
02201	Instantaneous flow rate O.K judgment range RAM
02202	Instantaneous flow rate O.K judgment hysteresis RAM
02203	Instantaneous flow rate deviation upper limit alarm RAM
02204	Instantaneous flow rate deviation upper limit alarm hysteresis RAM
02205	Instantaneous flow rate deviation lower limit alarm RAM
02206	Instantaneous flow rate deviation lower limit alarm hysteresis RAM
02207	Instantaneous flow rate deviation alarm judgment delay time RAM
02208	Event output 1 delay RAM
02209	Event output 2 delay RAM
02210	User setup conversion factor RAM
02211	Valve amperage upper limit alarm RAM
02212	Valve amperage lower limit alarm RAM
02213	Event output 1 upper/lower limit flow rate setup RAM
02214	Event output 2 upper/lower limit flow rate setup RAM
02215	SP ramp control ramp 1 RAM
02216	SP ramp control ramp 2 RAM
02217	Analog scaling RAM
02218	Cumulative flow event setting (last 4 digits) RAM
02219	Cumulative flow event setting (first 4 digits) RAM
02220	PV forced zero function delay RAM
02221	SP upper limit flow rate RAM
02222	SP lower limit flow rate RAM
04001	Gas type EEPROM
04002	Full- scale flow rate EEPROM 
04003	Decimal point position of instantaneous flow rate EEPROM  
04004	Decimal point position of integrated flow rate EEPROM   
04005	Instantaneous flow rate unit EEPROM
04006	Integrated flow rate unit EEPROM
04201	Alarm status bit EEPROM
04201.0	Deviation lower limit alarm of instantaneous flow rate (AL01) EEPROM
04201.1	Deviation upper limit alarm of instantaneous flow rate (AL02) EEPROM
04201.2	Valve amperage lower limit alarm (AL11) EEPROM
04201.3	Valve amperage upper limit alarm (AL12) EEPROM
04201.4	Sensor error (common to AL81, AL82 and AL83) EEPROM
04201.5	Input / output adjustment data error (AL91) EEPROM
04201.6	Sensor calibration data error (AL92) EEPROM
04201.7	User setup data error (AL93) EEPROM
04201.8	Valve overheat prevention limit operation (AL71) EEPROM
04201.9	Sensor error 1 (AL81) EEPROM
04201.A	Sensor error 2 (AL82) EEPROM
04201.B	Sensor error 3 (AL83) EEPROM
04202	Event status bit EEPROM
04202.0	Event output 1 status EEPROM
04202.1	Event output 2 status EEPROM
04202.3	External contact 1 input status EEPROM
04202.4	External contact 2 input status EEPROM
04202.5	External contact 3 input status EEPROM
04202.6	External 3-stage switching input status 1 (0V input) EEPROM
04202.7	External 3-stage switching input status 2 (5V input) EEPROM
04203	Control status bit EEPROM
04203.0	OK lamp (PV control status)  0: Light-out 1: Lighting (Instantaneous PV OK) EEPROM
04203.1	Slow start operation 0: Normal operation 1: Slow start operation EEPROM 
04203.2	Digital setting / Analog setting 0: Digital setting 1: Analog setting EEPROM 
04203.3	Totalizing count status 0: Totalized flow PV < Totalized flow event SP 1: Totalized flow PV > or = Totalized flow event SP EEPROM 
04203.4	SP ramp control function 0: Function disabled 1: SP ramp control enabled EEPROM 
04204	Operation mode EEPROM
04205	Instantaneous SP No. in use EEPROM
04206	Instantaneous SP value in use EEPROM
04207	Instantaneous PV value EEPROM
04208	Valve actuation current EEPROM
04401	Flow set value SP-0 EEPROM 
04402	Flow set value SP-1 EEPROM
04403	Flow set value SP-2 EEPROM
04404	Flow set value SP-3 EEPROM
04405	Flow set value SP-4 EEPROM
04406	Flow set value SP-5 EEPROM
04407	Flow set value SP-6 EEPROM
04408	Flow set value SP-7 EEPROM
04601	Totalized flow event setting lower 4 digits EEPROM
04602	Totalized flow event setting upper 4 digits EEPROM
04603	Totalized flow lower 4 digits EEPROM
04604	Totalized flow upper 4 digits EEPROM
05001	Key lock Run EEPROM
05002	RUN key operation selection and operation mode selection when power turned ON EEPROM
05003	Flow rate setup method (SP setup method selection) EEPROM
05004	Number of flow set value selection (number of SPs selection) EEPROM
05005	Input range selection of analog setup (analog SP input range selection) EEPROM
05006	Analog output type and range selection (analog PV output range selection) EEPROM
05007	Event 1 output type assignment EEPROM
05008	Event 2 output type assignment EEPROM
05009	External 3-stage switching function assignment EEPROM
05010	External contact input 1 function assignment EEPROM  
05011	External contact input 2 function assignment EEPROM
05012	External contact input 3 function assignment EEPROM
05013	Automatic valve shut-off when the totalized flow event occurs EEPROM
05014	On/off of totalized flow reset function at start of control EEPROM
05015	Flow rate alarm setup type EEPROM
05016	Operation selection at alarm occurrence EEPROM
05017	Slow start setup EEPROM
05018	Gas type selection 1 EEPROM
05019	Flow rate display unit selection(reference conditions) EEPROM
05020	Valve amperage alarm setup type selection EEPROM
05021	Direct setup function ON/OFF EEPROM
05022	Control dead zone setting EEPROM
05023	PV filter (process for filtering of instantaneous flow rate) EEPROM
05024	Flow rate range setup 1 EEPROM
05025	Flow rate range setup 2 EEPROM
05026	Gas type selection 2 EEPROM
05027	SP ramp control function EEPROM
05028	Analog scaling function EEPROM
05029	Forced PV (instantaneous flow rate) zero function EEPROM
05030	Station address setting EEPROM
05031	Transmission speed selection EEPROM
05032	Data format selection EEPROM
05035	SP limit function EEPROM
05036	Operational differential pressure setting (control optimization) EEPROM
05037	Flow rate display unit change function EEPROM
05038	PV (instantaneous flow rate) display decimal point position change function EEPROM
05201	Instantaneous flow rate O.K judgment range EEPROM 
05202	Instantaneous flow rate O.K judgment hysteresis EEPROM
05203	Instantaneous flow rate deviation upper limit alarm EEPROM
05204	Instantaneous flow rate deviation upper limit alarm hysteresis EEPROM
05205	Instantaneous flow rate deviation lower limit alarm EEPROM
05206	Instantaneous flow rate deviation lower limit alarm hysteresis EEPROM
05207	Instantaneous flow rate deviation alarm judgment delay time EEPROM
05208	Event output 1 delay EEPROM
05209	Event output 2 delay EEPROM
05210	User setup conversion factor EEPROM
05211	Valve amperage upper limit alarm EEPROM
05212	Valve amperage lower limit alarm EEPROM
05213	Event output 1 upper/lower limit flow rate setup EEPROM
05214	Event output 2 upper/lower limit flow rate setup EEPROM
05215	SP ramp control ramp 1 EEPROM
05216	SP ramp control ramp 2 EEPROM
05217	Analog scaling EEPROM
05218	Cumulative flow event setting (last 4 digits) EEPROM
05219	Cumulative flow event setting (first 4 digits) EEPROM
05220	PV forced zero function delay EEPROM
05221	SP upper limit flow rate EEPROM
05222	SP lower limit flow rate EEPROM
[SigDataEnd]