﻿Name=PLC1
MPC
MaxSigCnt=152
DataFormat=Decimal

[SigData]
01001	Gas type RAM
01002	Full- scale flow RAM
01003	Decimal point display position of instantaneous flowrate RAM
01004	Decimal point display position of integrated flowrate RAM
01201	Alarm status bit RAM
01201.0	Flowrate deviation lower limit alarm RAM
01201.1	Flowrate deviation upper limit alarm RAM
01201.4	Sensor error RAM
01201.5	Input / output adjustment data error RAM
01201.6	Sensor calibration data error RAM
01201.7	User setup data error RAM
01201.8	Valve overheat prevention limit is operated RAM
01202	Event status bit RAM
01202.0	Event output 1 status RAM
01202.1	Event output 2 status RAM
01202.3	External switch input 1 status RAM
01202.4	External switch input 2 status RAM
01203	Control status bit RAM
01203.0	OK lamp (Instantaneous PV control status) 0: Light-out 1: Lighting (Instantaneous PV OK) RAM
01203.1	Slow start operation 0: Normal operation 1: Slow start operation RAM
01203.2	Digital setting / Analog setting 0: Digital setting 1: Analog setting RAM
01203.3	Integrated count status 0: Integrated PV < Integrated SP 1: Integrated PV > or = Integrated SP RAM
01204	Operation mode RAM
01205	Instantaneous SP No. in use RAM
01206	Instantaneous SP value in use RAM
01207	Instantaneous PV value RAM
01208	Valve drive current output RAM
01401	Digital instantaneous flowrate SP-0 RAM
01402	Digital instantaneous flowrate SP-1 RAM
01403	Digital instantaneous flowrate SP-2 RAM
01404	Digital instantaneous flowrate SP-3 RAM
01601	Integrated SP setup lower 4 digits RAM
01602	Integrated SP setup upper 4 digits RAM
01603	Integrated PV setup lower 4 digits RAM
01604	Integrated PV setup upper 4 digits RAM
02001	Key lock RAM
02002	Operation mode selection (selection by key operation) RAM
02003	Instantaneous flow rate setup method (instantaneous SP setup method selection) RAM
02004	Number of instantaneous flowrate setups selection (number of instantaneous SPs selection) RAM
02005	Instantaneous flowrate analog input voltage range selection (SP analog input voltage range selection) RAM
02006	Instantaneous  flowrate analog output voltage range selection (PV analog output voltage range selection) RAM
02007	Event 1 output type assignment RAM
02008	Event 2 output type assignment RAM
02010	External contact 1 input function assignment RAM
02011	External contact 2 input function assignment RAM
02013	Automatic valve  shut-off function at integrated flowrate event occurrence RAM
02014	Switching of integrated reset function at start of control RAM
02015	Flowrate alarm setup type RAM
02016	Operation selection at alarm occurrence RAM
02017	Slow start setup RAM
02018	Gas type selection RAM
02019	Flowrate display unit selection RAM
02020	Inlet pressure setup RAM
02021	Instantaneous flowrate direct setting functional change RAM
02023	PV filter (Average) RAM
02028	Analog optional scaling function RAM
02029	PV forced zero function RAM
02030	Station address setting RAM
02031	Transmission speed selection RAM
02032	Communication conditions selection RAM
02201	Instantaneous flowrate O.K judgment range RAM
02202	Instantaneous flowrate O.K judgment hysteresis RAM
02203	Instantaneous flowrate deviation high limit alarm RAM
02204	Instantaneous flowrate deviation high limit alarm hysteresis RAM
02205	Instantaneous flowrate deviation lower limit alarm RAM
02206	Instantaneous flowrate deviation lower limit alarm hysteresis RAM
02207	Instantaneous flowrate deviation alarm judgment delay time RAM
02208	Event 1 output delay time RAM
02209	Event 2 output delay time RAM
02210	User setup conversion factor(C.F.) RAM
02213	Event 1 output high-low limit flowrate setup RAM
02214	Event 2 output high-low limit flowrate setup RAM
02217	Analog option scaling function RAM
02218	Integrated SP setup lower 4 digits RAM
02219	Integrated SP setup upper 4 digits RAM
02220	PV forced zero function delay time RAM
04001	Gas type EEPROM
04002	Full- scale flow EEPROM
04003	Decimal point display position of instantaneous flowrate EEPROM
04004	Decimal point display position of integrated flowrate EEPROM
04201	Alarm status bit EEPROM
04201.0	Flowrate deviation lower limit alarm EEPROM
04201.1	Flowrate deviation upper limit alarm EEPROM
04201.4	Sensor error EEPROM
04201.5	Input / output adjustment data error EEPROM
04201.6	Sensor calibration data error EEPROM
04201.7	User setup data error EEPROM
04201.8	Valve overheat prevention limit is operated EEPROM
04202	Event status bit EEPROM
04202.0	Event output 1 status EEPROM
04202.1	Event output 2 status EEPROM
04202.3	External switch input 1 status EEPROM
04202.4	External switch input 2 status EEPROM
04203	Control status bit EEPROM
04203.0	OK lamp (Instantaneous PV control status) 0: Light-out 1: Lighting (Instantaneous PV OK) EEPROM
04203.1	Slow start operation 0: Normal operation 1: Slow start operation EEPROM
04203.2	Digital setting / Analog setting 0: Digital setting 1: Analog setting EEPROM
04203.3	Integrated count status 0: Integrated PV < Integrated SP 1: Integrated PV > or = Integrated SP EEPROM
04204	Operation mode EEPROM
04205	Instantaneous SP No. in use EEPROM
04206	Instantaneous SP value in use EEPROM
04207	Instantaneous PV value EEPROM
04208	Valve drive current output EEPROM
04401	Digital instantaneous flowrate SP-0 EEPROM
04402	Digital instantaneous flowrate SP-1 EEPROM
04403	Digital instantaneous flowrate SP-2 EEPROM
04404	Digital instantaneous flowrate SP-3 EEPROM
04601	Integrated SP setup lower 4 digits EEPROM
04602	Integrated SP setup upper 4 digits EEPROM
04603	Integrated PV setup lower 4 digits EEPROM
04604	Integrated PV setup upper 4 digits EEPROM
05001	Key lock EEPROM
05002	Operation mode selection (selection by key operation) EEPROM
05003	Instantaneous flow rate setup method (instantaneous SP setup method selection) EEPROM
05004	Number of instantaneous flowrate setups selection (number of instantaneous SPs selection) EEPROM
05005	Instantaneous flowrate analog input voltage range selection (SP analog input voltage range selection) EEPROM
05006	Instantaneous  flowrate analog output voltage range selection (PV analog output voltage range selection) EEPROM
05007	Event 1 output type assignment EEPROM
05008	Event 2 output type assignment EEPROM
05010	External contact 1 input function assignment EEPROM
05011	External contact 2 input function assignment EEPROM
05013	Automatic valve  shut-off function at integrated flowrate event occurrence EEPROM
05014	Switching of integrated reset function at start of control EEPROM
05015	Flowrate alarm setup type EEPROM
05016	Operation selection at alarm occurrence EEPROM
05017	Slow start setup EEPROM
05018	Gas type selection EEPROM
05019	Flowrate display unit selection EEPROM
05020	Inlet pressure setup EEPROM
05021	Instantaneous flowrate direct setting functional change EEPROM
05023	PV filter (Average) EEPROM
05028	Analog optional scaling function EEPROM
05029	PV forced zero function EEPROM
05030	Station address setting EEPROM
05031	Transmission speed selection EEPROM
05032	Communication conditions selection EEPROM
05201	Instantaneous flowrate O.K judgment range EEPROM
05202	Instantaneous flowrate O.K judgment hysteresis EEPROM
05203	Instantaneous flowrate deviation high limit alarm EEPROM
05204	Instantaneous flowrate deviation high limit alarm hysteresis EEPROM
05205	Instantaneous flowrate deviation lower limit alarm EEPROM
05206	Instantaneous flowrate deviation lower limit alarm hysteresis EEPROM
05207	Instantaneous flowrate deviation alarm judgment delay time EEPROM
05208	Event 1 output delay time EEPROM
05209	Event 2 output delay time EEPROM
05210	User setup conversion factor(C.F.) EEPROM
05213	Event 1 output high-low limit flowrate setup EEPROM
05214	Event 2 output high-low limit flowrate setup EEPROM
05217	Analog option scaling function EEPROM
05218	Integrated SP setup lower 4 digits EEPROM
05219	Integrated SP setup upper 4 digits EEPROM
05220	PV forced zero function delay time EEPROM
[SigDataEnd]